{"id":"weidmueller-article-1315750000","name":"UR20-1COM-232-485-422 — Field bus, decentralized peripheral - communications module / Communication module (I/O) Functional module, PUSH IN, 24 V DC +20 %/ -15 %, via the system bus, -20 °C ... +60 °C","manufacturer":"Weidmüller","category":"automation","description":"Weidmüller UR20-1COM-232-485-422 — Field bus, decentralized peripheral - communications module / Communication module (I/O) Functional module, PUSH IN, 24 V DC +20 %/ -15 %, via the system bus, -20 °C ... +60 °C. Manufacturer CAD files for automation equipment selection and layout, identified by article 1315750000.","equipment":["automation","UR20-1COM-232-485-422 — Field bus, decentralized peripheral - communications module / Communication module (I/O) Functional module, PUSH IN, 24 V DC +20 %/ -15 %, via the system bus, -20 °C ... +60 °C"],"keywords":["Weidmüller","UR20-1COM-232-485-422 — Field bus, decentralized peripheral - communications module / Communication module (I/O) Functional module, PUSH IN, 24 V DC +20 %/ -15 %, via the system bus, -20 °C ... +60 °C","1315750000","automation","DWG","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"1315750000","sourceUrl":"https://eshop.weidmueller.com.cn/en/ur20-1com-232-485-422/p/1315750000/downloads#engineering-support","officialEvidenceUrl":"https://eshop.weidmueller.com.cn/en/ur20-1com-232-485-422/p/1315750000/downloads#engineering-support","sourcePublisher":"Weidmüller","formats":["DWG","DXF","STEP"],"availability":"direct","accessNote":"Manufacturer CAD files for the listed equipment reference. Open the original files in compatible CAD software.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"1315750000","sourceUrl":"https://eshop.weidmueller.com.cn/en/ur20-1com-232-485-422/p/1315750000/downloads#engineering-support"},{"label":"Manufacturer type","value":"UR20-1COM-232-485-422","sourceUrl":"https://eshop.weidmueller.com.cn/en/ur20-1com-232-485-422/p/1315750000/downloads#engineering-support"},{"label":"Available native formats","value":"DWG / DXF / STEP","sourceUrl":"https://eshop.weidmueller.com.cn/en/ur20-1com-232-485-422/p/1315750000/downloads#engineering-support"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-7083733e94c69dc06158e946-step","name":"1315750000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://assets.dam.weidmueller.com/assets/api/ef591ad2-6462-4993-bc2a-95e50ee9ae1d/original/1315750000.stp","availability":"direct","sha256":"7083733e94c69dc06158e9461045fe07e44dadcb6602036bae53cef9de5cb485","bytes":3620014,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"1315750000.stp.zip","format":"ZIP","sha256":"b58de5dd5da08b23be2a745e6740d06dd8dfb60de9584ea93af91257121e0241","bytes":582079,"includes":["1315750000.stp"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/ef591ad2-6462-4993-bc2a-95e50ee9ae1d/original/1315750000.stp","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1315750000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1315750000/native-7083733e94c69dc06158e946-step"},{"id":"native-fbd1875227ef712db3ca339c-zip","name":"1315750000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/17d63f42-81ed-4b23-8c50-d6413c9a3be3/original/1315750000_DXF.zip","availability":"direct","sha256":"fbd1875227ef712db3ca339c20b96e3eb107dafc010e3b3fff6b3867404ead1a","bytes":67263,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"1315750000_DXF.zip","format":"ZIP","sha256":"fbd1875227ef712db3ca339c20b96e3eb107dafc010e3b3fff6b3867404ead1a","bytes":67263,"includes":["1315750000_DXF.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/17d63f42-81ed-4b23-8c50-d6413c9a3be3/original/1315750000_DXF.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["1315750000_back.DXF","1315750000_bottom.DXF","1315750000_front.DXF","1315750000_left.DXF","1315750000_right.DXF","1315750000_top.DXF"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1315750000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1315750000/native-fbd1875227ef712db3ca339c-zip"},{"id":"native-372809c408a9588a94f5db87-zip","name":"1315750000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/d15c9a03-1de0-46fa-892a-4e51714dd0c5/original/1315750000_DWG.zip","availability":"direct","sha256":"372809c408a9588a94f5db875011b1d5a5c53466874960b662e478d5e2a0b358","bytes":88557,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"1315750000_DWG.zip","format":"ZIP","sha256":"372809c408a9588a94f5db875011b1d5a5c53466874960b662e478d5e2a0b358","bytes":88557,"includes":["1315750000_DWG.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/d15c9a03-1de0-46fa-892a-4e51714dd0c5/original/1315750000_DWG.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["1315750000_back.DWG","1315750000_bottom.DWG","1315750000_front.DWG","1315750000_left.DWG","1315750000_right.DWG","1315750000_top.DWG"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1315750000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1315750000/native-372809c408a9588a94f5db87-zip"}],"artifacts":[{"id":"native-7083733e94c69dc06158e946-step","name":"1315750000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/ef591ad2-6462-4993-bc2a-95e50ee9ae1d/original/1315750000.stp","sourceSha256":"7083733e94c69dc06158e9461045fe07e44dadcb6602036bae53cef9de5cb485","artifactSha256":"b58de5dd5da08b23be2a745e6740d06dd8dfb60de9584ea93af91257121e0241","bytes":582079,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1315750000/native-7083733e94c69dc06158e946-step","customerPrice":0},{"id":"native-fbd1875227ef712db3ca339c-zip","name":"1315750000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DXF"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/17d63f42-81ed-4b23-8c50-d6413c9a3be3/original/1315750000_DXF.zip","sourceSha256":"fbd1875227ef712db3ca339c20b96e3eb107dafc010e3b3fff6b3867404ead1a","artifactSha256":"fbd1875227ef712db3ca339c20b96e3eb107dafc010e3b3fff6b3867404ead1a","bytes":67263,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1315750000/native-fbd1875227ef712db3ca339c-zip","customerPrice":0},{"id":"native-372809c408a9588a94f5db87-zip","name":"1315750000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/d15c9a03-1de0-46fa-892a-4e51714dd0c5/original/1315750000_DWG.zip","sourceSha256":"372809c408a9588a94f5db875011b1d5a5c53466874960b662e478d5e2a0b358","artifactSha256":"372809c408a9588a94f5db875011b1d5a5c53466874960b662e478d5e2a0b358","bytes":88557,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1315750000/native-372809c408a9588a94f5db87-zip","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"UR20-1COM-232-485-422 — Field bus, decentralized peripheral - communications module / Communication module (I/O) Functional module, PUSH IN, 24 V DC +20 %/ -15 %, via the system bus, -20 °C ... +60 °C"},{"label":"Manufacturer","value":"Weidmüller"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"1315750000"},{"label":"Manufacturer reference","value":"1315750000"},{"label":"Manufacturer type","value":"UR20-1COM-232-485-422"},{"label":"Available native formats","value":"DWG / DXF / STEP"},{"label":"Listed file formats","value":"DWG, DXF, STEP"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"2 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 50 files / 512 MiB daily; registered free: 1,000 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/weidmueller-article-1315750000/native-fbd1875227ef712db3ca339c-zip?asset=9e308db822141c2089e4096c1fd379a7b144b2f055fdc5467b02cc4de9cddff1","relatedReferences":[{"name":"PLC CPU module","url":"https://eloragrid.ai/objects/ga-plc-cpu-module"},{"name":"HMI touchscreen","url":"https://eloragrid.ai/objects/ga-hmi-touchscreen"}],"fileChoiceGuidance":["Start with 1315750000. The files above belong to Weidmüller's UR20-1COM-232-485-422 — Field bus, decentralized peripheral - communications module / Communication module (I/O) Functional module, PUSH IN, 24 V DC +20 %/ -15 %, via the system bus, -20 °C ... +60 °C resource; match any model or option suffix in the filename to your selected unit.","Available here: STEP, ZIP. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"An input/output assembly connects field devices to a controller. Inputs report measurements or status; outputs pass the controller's commands to equipment.","example":"In a switchroom, a remote I/O station can collect fan-status contacts and send ventilation-control commands without every signal returning to the main controller rack.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Field signals","Input and output assembly","Controller information and commands"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Weidmüller official source","url":"https://eshop.weidmueller.com.cn/en/ur20-1com-232-485-422/p/1315750000/downloads#engineering-support"}],"profileId":"plc-combined"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/weidmueller-article-1315750000"}