{"id":"weidmueller-article-1334810000","name":"UR20-16AUX-GND-O — Field bus, decentralized peripheral - feed and segment module / Potential distribution module (I/O)","manufacturer":"Weidmüller","category":"automation","description":"Weidmüller UR20-16AUX-GND-O — Field bus, decentralized peripheral - feed and segment module / Potential distribution module (I/O). Manufacturer CAD files for automation equipment selection and layout, identified by article 1334810000.","equipment":["automation","UR20-16AUX-GND-O — Field bus, decentralized peripheral - feed and segment module / Potential distribution module (I/O)"],"keywords":["Weidmüller","UR20-16AUX-GND-O — Field bus, decentralized peripheral - feed and segment module / Potential distribution module (I/O)","1334810000","automation","DWG","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"1334810000","sourceUrl":"https://eshop.weidmueller.com.cn/en/ur20-16aux-gnd-o/p/1334810000/downloads#engineering-support","officialEvidenceUrl":"https://eshop.weidmueller.com.cn/en/ur20-16aux-gnd-o/p/1334810000/downloads#engineering-support","sourcePublisher":"Weidmüller","formats":["DWG","DXF","STEP"],"availability":"direct","accessNote":"Manufacturer CAD files for the listed equipment reference. Open the original files in compatible CAD software.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"1334810000","sourceUrl":"https://eshop.weidmueller.com.cn/en/ur20-16aux-gnd-o/p/1334810000/downloads#engineering-support"},{"label":"Manufacturer type","value":"UR20-16AUX-GND-O","sourceUrl":"https://eshop.weidmueller.com.cn/en/ur20-16aux-gnd-o/p/1334810000/downloads#engineering-support"},{"label":"Available native formats","value":"DWG / DXF / STEP","sourceUrl":"https://eshop.weidmueller.com.cn/en/ur20-16aux-gnd-o/p/1334810000/downloads#engineering-support"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-bdb39f778fbd34f31b8848fb-step","name":"1334810000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://assets.dam.weidmueller.com/assets/api/15b92638-545b-4697-839b-ed2971f9d6ee/original/1334810000.stp","availability":"direct","sha256":"bdb39f778fbd34f31b8848fb88c8e99f24284b8b467ecb95a369ee5266ab9a51","bytes":823523,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"1334810000.stp.zip","format":"ZIP","sha256":"31750781838bc8d804c14e49bb6abfeb59a2822aa373e4a24ece5f602ac8f8d9","bytes":131100,"includes":["1334810000.stp"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/15b92638-545b-4697-839b-ed2971f9d6ee/original/1334810000.stp","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1334810000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1334810000/native-bdb39f778fbd34f31b8848fb-step"},{"id":"native-df5e5b0585b73694578a282e-zip","name":"1334810000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/206f6e73-45c2-4b87-aaa4-1663069680f2/original/1334810000_DXF.zip","availability":"direct","sha256":"df5e5b0585b73694578a282ed21ac53cf9830d6be439df9ed197fe68b905369c","bytes":40322,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"1334810000_DXF.zip","format":"ZIP","sha256":"df5e5b0585b73694578a282ed21ac53cf9830d6be439df9ed197fe68b905369c","bytes":40322,"includes":["1334810000_DXF.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/206f6e73-45c2-4b87-aaa4-1663069680f2/original/1334810000_DXF.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["1334810000_back.DXF","1334810000_bottom.DXF","1334810000_front.DXF","1334810000_left.DXF","1334810000_right.DXF","1334810000_top.DXF"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1334810000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1334810000/native-df5e5b0585b73694578a282e-zip"},{"id":"native-3b947eeb2712d5d3bb13feca-zip","name":"1334810000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/3e3e2287-87e7-4208-ab0a-599ee4009bcc/original/1334810000_DWG.zip","availability":"direct","sha256":"3b947eeb2712d5d3bb13feca60219604bd5ac2dc6bb333985d8e182bb7130c02","bytes":61207,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"1334810000_DWG.zip","format":"ZIP","sha256":"3b947eeb2712d5d3bb13feca60219604bd5ac2dc6bb333985d8e182bb7130c02","bytes":61207,"includes":["1334810000_DWG.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/3e3e2287-87e7-4208-ab0a-599ee4009bcc/original/1334810000_DWG.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["1334810000_back.DWG","1334810000_bottom.DWG","1334810000_front.DWG","1334810000_left.DWG","1334810000_right.DWG","1334810000_top.DWG"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1334810000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1334810000/native-3b947eeb2712d5d3bb13feca-zip"}],"artifacts":[{"id":"native-bdb39f778fbd34f31b8848fb-step","name":"1334810000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/15b92638-545b-4697-839b-ed2971f9d6ee/original/1334810000.stp","sourceSha256":"bdb39f778fbd34f31b8848fb88c8e99f24284b8b467ecb95a369ee5266ab9a51","artifactSha256":"31750781838bc8d804c14e49bb6abfeb59a2822aa373e4a24ece5f602ac8f8d9","bytes":131100,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1334810000/native-bdb39f778fbd34f31b8848fb-step","customerPrice":0},{"id":"native-df5e5b0585b73694578a282e-zip","name":"1334810000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DXF"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/206f6e73-45c2-4b87-aaa4-1663069680f2/original/1334810000_DXF.zip","sourceSha256":"df5e5b0585b73694578a282ed21ac53cf9830d6be439df9ed197fe68b905369c","artifactSha256":"df5e5b0585b73694578a282ed21ac53cf9830d6be439df9ed197fe68b905369c","bytes":40322,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1334810000/native-df5e5b0585b73694578a282e-zip","customerPrice":0},{"id":"native-3b947eeb2712d5d3bb13feca-zip","name":"1334810000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/3e3e2287-87e7-4208-ab0a-599ee4009bcc/original/1334810000_DWG.zip","sourceSha256":"3b947eeb2712d5d3bb13feca60219604bd5ac2dc6bb333985d8e182bb7130c02","artifactSha256":"3b947eeb2712d5d3bb13feca60219604bd5ac2dc6bb333985d8e182bb7130c02","bytes":61207,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1334810000/native-3b947eeb2712d5d3bb13feca-zip","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"UR20-16AUX-GND-O — Field bus, decentralized peripheral - feed and segment module / Potential distribution module (I/O)"},{"label":"Manufacturer","value":"Weidmüller"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"1334810000"},{"label":"Manufacturer reference","value":"1334810000"},{"label":"Manufacturer type","value":"UR20-16AUX-GND-O"},{"label":"Available native formats","value":"DWG / DXF / STEP"},{"label":"Listed file formats","value":"DWG, DXF, STEP"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"2 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 50 files / 512 MiB daily; registered free: 1,000 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/weidmueller-article-1334810000/native-df5e5b0585b73694578a282e-zip?asset=f1928095bc3a3b95592aa04890b6137ee077660f39590ddbedb3d121f6cfb53a","relatedReferences":[{"name":"PLC CPU module","url":"https://eloragrid.ai/objects/ga-plc-cpu-module"},{"name":"HMI touchscreen","url":"https://eloragrid.ai/objects/ga-hmi-touchscreen"}],"fileChoiceGuidance":["Start with 1334810000. The files above belong to Weidmüller's UR20-16AUX-GND-O — Field bus, decentralized peripheral - feed and segment module / Potential distribution module (I/O) resource; match any model or option suffix in the filename to your selected unit.","Available here: STEP, ZIP. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"An input/output assembly connects field devices to a controller. Inputs report measurements or status; outputs pass the controller's commands to equipment.","example":"In a switchroom, a remote I/O station can collect fan-status contacts and send ventilation-control commands without every signal returning to the main controller rack.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Field signals","Input and output assembly","Controller information and commands"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Weidmüller official source","url":"https://eshop.weidmueller.com.cn/en/ur20-16aux-gnd-o/p/1334810000/downloads#engineering-support"}],"profileId":"plc-combined"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/weidmueller-article-1334810000"}