{"id":"weidmueller-article-1508080000","name":"UR20-2FCNT-100 — Field bus, decentralized peripheral - function-/technology module / Counter module (I/O)","manufacturer":"Weidmüller","category":"automation","description":"Weidmüller UR20-2FCNT-100 — Field bus, decentralized peripheral - function-/technology module / Counter module (I/O). Manufacturer CAD files for automation equipment selection and layout, identified by article 1508080000.","equipment":["automation","UR20-2FCNT-100 — Field bus, decentralized peripheral - function-/technology module / Counter module (I/O)"],"keywords":["Weidmüller","UR20-2FCNT-100 — Field bus, decentralized peripheral - function-/technology module / Counter module (I/O)","1508080000","automation","DWG","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"1508080000","sourceUrl":"https://eshop.weidmueller.com.cn/en/ur20-2fcnt-100/p/1508080000/downloads#engineering-support","officialEvidenceUrl":"https://eshop.weidmueller.com.cn/en/ur20-2fcnt-100/p/1508080000/downloads#engineering-support","sourcePublisher":"Weidmüller","formats":["DWG","DXF","STEP"],"availability":"direct","accessNote":"Manufacturer CAD files for the listed equipment reference. Open the original files in compatible CAD software.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"1508080000","sourceUrl":"https://eshop.weidmueller.com.cn/en/ur20-2fcnt-100/p/1508080000/downloads#engineering-support"},{"label":"Manufacturer type","value":"UR20-2FCNT-100","sourceUrl":"https://eshop.weidmueller.com.cn/en/ur20-2fcnt-100/p/1508080000/downloads#engineering-support"},{"label":"Available native formats","value":"DWG / DXF / STEP","sourceUrl":"https://eshop.weidmueller.com.cn/en/ur20-2fcnt-100/p/1508080000/downloads#engineering-support"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-0bd2bcc623f07cc75bf351a1-zip","name":"1508080000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/99cc5c35-db91-4967-a012-07760dac5f6c/original/1508080000_DWG.zip","availability":"direct","sha256":"0bd2bcc623f07cc75bf351a1029650b72ecf2bdff12ee382c121dae5851fb497","bytes":56914,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"1508080000_DWG.zip","format":"ZIP","sha256":"0bd2bcc623f07cc75bf351a1029650b72ecf2bdff12ee382c121dae5851fb497","bytes":56914,"includes":["1508080000_DWG.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/99cc5c35-db91-4967-a012-07760dac5f6c/original/1508080000_DWG.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["1508080000_back.DWG","1508080000_bottom.DWG","1508080000_front.DWG","1508080000_left.DWG","1508080000_right.DWG","1508080000_top.DWG"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1508080000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1508080000/native-0bd2bcc623f07cc75bf351a1-zip"},{"id":"native-c186cd38b6d675923f0209ff-zip","name":"1508080000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/9363dc2c-acba-4aaa-a77a-d53cbe6c3325/original/1508080000_DXF.zip","availability":"direct","sha256":"c186cd38b6d675923f0209fff679682e5bd7ccaf16ef59b5c546fc72fd831841","bytes":36737,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"1508080000_DXF.zip","format":"ZIP","sha256":"c186cd38b6d675923f0209fff679682e5bd7ccaf16ef59b5c546fc72fd831841","bytes":36737,"includes":["1508080000_DXF.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/9363dc2c-acba-4aaa-a77a-d53cbe6c3325/original/1508080000_DXF.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["1508080000_back.DXF","1508080000_bottom.DXF","1508080000_front.DXF","1508080000_left.DXF","1508080000_right.DXF","1508080000_top.DXF"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1508080000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1508080000/native-c186cd38b6d675923f0209ff-zip"},{"id":"native-70393d159408655d601f6f71-step","name":"1508080000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://assets.dam.weidmueller.com/assets/api/63d7f28f-9674-47c9-b33f-0cdac1de4818/original/1508080000.stp","availability":"direct","sha256":"70393d159408655d601f6f719ba4c39aef459044b7f3d29b93643358d552684e","bytes":842219,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"1508080000.stp.zip","format":"ZIP","sha256":"8de394000370eee8fe082a66709be55c64fa1aea05cc1788357e94ae9e5b43b0","bytes":137435,"includes":["1508080000.stp"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/63d7f28f-9674-47c9-b33f-0cdac1de4818/original/1508080000.stp","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1508080000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1508080000/native-70393d159408655d601f6f71-step"}],"artifacts":[{"id":"native-0bd2bcc623f07cc75bf351a1-zip","name":"1508080000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/99cc5c35-db91-4967-a012-07760dac5f6c/original/1508080000_DWG.zip","sourceSha256":"0bd2bcc623f07cc75bf351a1029650b72ecf2bdff12ee382c121dae5851fb497","artifactSha256":"0bd2bcc623f07cc75bf351a1029650b72ecf2bdff12ee382c121dae5851fb497","bytes":56914,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1508080000/native-0bd2bcc623f07cc75bf351a1-zip","customerPrice":0},{"id":"native-c186cd38b6d675923f0209ff-zip","name":"1508080000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DXF"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/9363dc2c-acba-4aaa-a77a-d53cbe6c3325/original/1508080000_DXF.zip","sourceSha256":"c186cd38b6d675923f0209fff679682e5bd7ccaf16ef59b5c546fc72fd831841","artifactSha256":"c186cd38b6d675923f0209fff679682e5bd7ccaf16ef59b5c546fc72fd831841","bytes":36737,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1508080000/native-c186cd38b6d675923f0209ff-zip","customerPrice":0},{"id":"native-70393d159408655d601f6f71-step","name":"1508080000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/63d7f28f-9674-47c9-b33f-0cdac1de4818/original/1508080000.stp","sourceSha256":"70393d159408655d601f6f719ba4c39aef459044b7f3d29b93643358d552684e","artifactSha256":"8de394000370eee8fe082a66709be55c64fa1aea05cc1788357e94ae9e5b43b0","bytes":137435,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1508080000/native-70393d159408655d601f6f71-step","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"UR20-2FCNT-100 — Field bus, decentralized peripheral - function-/technology module / Counter module (I/O)"},{"label":"Manufacturer","value":"Weidmüller"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"1508080000"},{"label":"Manufacturer reference","value":"1508080000"},{"label":"Manufacturer type","value":"UR20-2FCNT-100"},{"label":"Available native formats","value":"DWG / DXF / STEP"},{"label":"Listed file formats","value":"DWG, DXF, STEP"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"2 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 50 files / 512 MiB daily; registered free: 1,000 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/weidmueller-article-1508080000/native-0bd2bcc623f07cc75bf351a1-zip?asset=fd9c0cead4cfbed7f1979793c272de0e8e4baa9721adce95c2336b6e19bd7394","relatedReferences":[{"name":"PLC CPU module","url":"https://eloragrid.ai/objects/ga-plc-cpu-module"},{"name":"HMI touchscreen","url":"https://eloragrid.ai/objects/ga-hmi-touchscreen"}],"fileChoiceGuidance":["Start with 1508080000. The files above belong to Weidmüller's UR20-2FCNT-100 — Field bus, decentralized peripheral - function-/technology module / Counter module (I/O) resource; match any model or option suffix in the filename to your selected unit.","Available here: ZIP, STEP. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"An input/output assembly connects field devices to a controller. Inputs report measurements or status; outputs pass the controller's commands to equipment.","example":"In a switchroom, a remote I/O station can collect fan-status contacts and send ventilation-control commands without every signal returning to the main controller rack.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Field signals","Input and output assembly","Controller information and commands"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Weidmüller official source","url":"https://eshop.weidmueller.com.cn/en/ur20-2fcnt-100/p/1508080000/downloads#engineering-support"}],"profileId":"plc-combined"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/weidmueller-article-1508080000"}