{"id":"weidmueller-article-1698140000","name":"HDC-C-M3-SM2.5AG — Contact (industry plug-in connectors) / Contact (industry plug-in connectors), Pin, CM 3, 2.5 mm², 3.6 mm, turned","manufacturer":"Weidmüller","category":"wiring","description":"Weidmüller HDC-C-M3-SM2.5AG — Contact (industry plug-in connectors) / Contact (industry plug-in connectors), Pin, CM 3, 2.5 mm², 3.6 mm, turned. Manufacturer CAD files for wiring equipment selection and layout, identified by article 1698140000.","equipment":["wiring","HDC-C-M3-SM2.5AG — Contact (industry plug-in connectors) / Contact (industry plug-in connectors), Pin, CM 3, 2.5 mm², 3.6 mm, turned"],"keywords":["Weidmüller","HDC-C-M3-SM2.5AG — Contact (industry plug-in connectors) / Contact (industry plug-in connectors), Pin, CM 3, 2.5 mm², 3.6 mm, turned","1698140000","wiring","DWG","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"1698140000","sourceUrl":"https://eshop.weidmueller.com.cn/en/hdc-c-m3-sm2-5ag/p/1698140000/downloads#engineering-support","officialEvidenceUrl":"https://eshop.weidmueller.com.cn/en/hdc-c-m3-sm2-5ag/p/1698140000/downloads#engineering-support","sourcePublisher":"Weidmüller","formats":["DWG","DXF","STEP"],"availability":"direct","accessNote":"Manufacturer CAD files for the listed equipment reference. Open the original files in compatible CAD software.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"1698140000","sourceUrl":"https://eshop.weidmueller.com.cn/en/hdc-c-m3-sm2-5ag/p/1698140000/downloads#engineering-support"},{"label":"Manufacturer type","value":"HDC-C-M3-SM2.5AG","sourceUrl":"https://eshop.weidmueller.com.cn/en/hdc-c-m3-sm2-5ag/p/1698140000/downloads#engineering-support"},{"label":"Available native formats","value":"DWG / DXF / STEP","sourceUrl":"https://eshop.weidmueller.com.cn/en/hdc-c-m3-sm2-5ag/p/1698140000/downloads#engineering-support"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-719432f614c2fb774e6fb9c3-step","name":"1698140000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://assets.dam.weidmueller.com/assets/api/0046ff0d-978c-4a78-a3c2-1873594415c8/original/1698140000.stp","availability":"direct","sha256":"719432f614c2fb774e6fb9c3d63d1ea4ca6735f8c4be5b1f298abe7a2c7f262e","bytes":69621,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"1698140000.stp.zip","format":"ZIP","sha256":"f5e432cce47d13000876d3836a33ad26a5c42bf6b8f0b89faf44089408532d92","bytes":13868,"includes":["1698140000.stp"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/0046ff0d-978c-4a78-a3c2-1873594415c8/original/1698140000.stp","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1698140000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1698140000/native-719432f614c2fb774e6fb9c3-step"},{"id":"native-8ec0bef0e0601d253540f7a1-zip","name":"1698140000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/44966191-48a2-47c0-b7a1-94d0d1d68f01/original/1698140000_DXF.zip","availability":"direct","sha256":"8ec0bef0e0601d253540f7a1c62f1dcce5883d299380512e983a0140bb124f95","bytes":31212,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"1698140000_DXF.zip","format":"ZIP","sha256":"8ec0bef0e0601d253540f7a1c62f1dcce5883d299380512e983a0140bb124f95","bytes":31212,"includes":["1698140000_DXF.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/44966191-48a2-47c0-b7a1-94d0d1d68f01/original/1698140000_DXF.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["1698140000_back.DXF","1698140000_bottom.DXF","1698140000_front.DXF","1698140000_left.DXF","1698140000_right.DXF","1698140000_top.DXF"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1698140000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1698140000/native-8ec0bef0e0601d253540f7a1-zip"},{"id":"native-e3adf29871300398c1e06714-zip","name":"1698140000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/4a11c857-c7e6-4178-9e02-603c1cc456bc/original/1698140000_DWG.zip","availability":"direct","sha256":"e3adf29871300398c1e06714aecc770d88ae3b0a48f2b25c5f0fa500d42c4be0","bytes":56832,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"1698140000_DWG.zip","format":"ZIP","sha256":"e3adf29871300398c1e06714aecc770d88ae3b0a48f2b25c5f0fa500d42c4be0","bytes":56832,"includes":["1698140000_DWG.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/4a11c857-c7e6-4178-9e02-603c1cc456bc/original/1698140000_DWG.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["1698140000_back.DWG","1698140000_bottom.DWG","1698140000_front.DWG","1698140000_left.DWG","1698140000_right.DWG","1698140000_top.DWG"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1698140000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1698140000/native-e3adf29871300398c1e06714-zip"}],"artifacts":[{"id":"native-719432f614c2fb774e6fb9c3-step","name":"1698140000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/0046ff0d-978c-4a78-a3c2-1873594415c8/original/1698140000.stp","sourceSha256":"719432f614c2fb774e6fb9c3d63d1ea4ca6735f8c4be5b1f298abe7a2c7f262e","artifactSha256":"f5e432cce47d13000876d3836a33ad26a5c42bf6b8f0b89faf44089408532d92","bytes":13868,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1698140000/native-719432f614c2fb774e6fb9c3-step","customerPrice":0},{"id":"native-8ec0bef0e0601d253540f7a1-zip","name":"1698140000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DXF"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/44966191-48a2-47c0-b7a1-94d0d1d68f01/original/1698140000_DXF.zip","sourceSha256":"8ec0bef0e0601d253540f7a1c62f1dcce5883d299380512e983a0140bb124f95","artifactSha256":"8ec0bef0e0601d253540f7a1c62f1dcce5883d299380512e983a0140bb124f95","bytes":31212,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1698140000/native-8ec0bef0e0601d253540f7a1-zip","customerPrice":0},{"id":"native-e3adf29871300398c1e06714-zip","name":"1698140000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/4a11c857-c7e6-4178-9e02-603c1cc456bc/original/1698140000_DWG.zip","sourceSha256":"e3adf29871300398c1e06714aecc770d88ae3b0a48f2b25c5f0fa500d42c4be0","artifactSha256":"e3adf29871300398c1e06714aecc770d88ae3b0a48f2b25c5f0fa500d42c4be0","bytes":56832,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1698140000/native-e3adf29871300398c1e06714-zip","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"HDC-C-M3-SM2.5AG — Contact (industry plug-in connectors) / Contact (industry plug-in connectors), Pin, CM 3, 2.5 mm², 3.6 mm, turned"},{"label":"Manufacturer","value":"Weidmüller"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"1698140000"},{"label":"Manufacturer reference","value":"1698140000"},{"label":"Manufacturer type","value":"HDC-C-M3-SM2.5AG"},{"label":"Available native formats","value":"DWG / DXF / STEP"},{"label":"Listed file formats","value":"DWG, DXF, STEP"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"2 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 50 files / 512 MiB daily; registered free: 1,000 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/weidmueller-article-1698140000/native-8ec0bef0e0601d253540f7a1-zip?asset=3a370d0712124316ce4dfe3152fd0124a9389e101c1478661463e99af8cdb150","relatedReferences":[{"name":"Terminal strip assembly","url":"https://eloragrid.ai/objects/terminal-strip"},{"name":"Cable gland","url":"https://eloragrid.ai/objects/ga-cable-gland"}],"fileChoiceGuidance":["Start with 1698140000. The files above belong to Weidmüller's HDC-C-M3-SM2.5AG — Contact (industry plug-in connectors) / Contact (industry plug-in connectors), Pin, CM 3, 2.5 mm², 3.6 mm, turned resource; match any model or option suffix in the filename to your selected unit.","Available here: STEP, ZIP. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"A connector provides a connection that can be separated without permanently joining the wires. Its matching parts and ratings determine what it can connect.","example":"In a switchroom control panel, a plug-and-socket connection can let a module be removed without undoing every wire individually.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Cable or device","Matching connector parts","Connected equipment"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Weidmüller official source","url":"https://eshop.weidmueller.com.cn/en/hdc-c-m3-sm2-5ag/p/1698140000/downloads#engineering-support"}],"profileId":"connector"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/weidmueller-article-1698140000"}