{"id":"weidmueller-article-1716690000","name":"VT-TM 0/18 HF — Conductor/Cable marker / Cable coding system, Transparent, Conductor O.D.:1.3 - 2 mm, Polyethylene LD, -40...80 °C","manufacturer":"Weidmüller","category":"transformers","description":"Weidmüller VT-TM 0/18 HF — Conductor/Cable marker / Cable coding system, Transparent, Conductor O.D.:1.3 - 2 mm, Polyethylene LD, -40...80 °C. Manufacturer CAD files for transformers equipment selection and layout, identified by article 1716690000.","equipment":["transformers","VT-TM 0/18 HF — Conductor/Cable marker / Cable coding system, Transparent, Conductor O.D.:1.3 - 2 mm, Polyethylene LD, -40...80 °C"],"keywords":["Weidmüller","VT-TM 0/18 HF — Conductor/Cable marker / Cable coding system, Transparent, Conductor O.D.:1.3 - 2 mm, Polyethylene LD, -40...80 °C","1716690000","transformers","DWG","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"1716690000","sourceUrl":"https://eshop.weidmueller.com.cn/en/vt-tm-018-hf/p/1716690000/downloads#engineering-support","officialEvidenceUrl":"https://eshop.weidmueller.com.cn/en/vt-tm-018-hf/p/1716690000/downloads#engineering-support","sourcePublisher":"Weidmüller","formats":["DWG","DXF","STEP"],"availability":"direct","accessNote":"Manufacturer CAD files for the listed equipment reference. Open the original files in compatible CAD software.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"1716690000","sourceUrl":"https://eshop.weidmueller.com.cn/en/vt-tm-018-hf/p/1716690000/downloads#engineering-support"},{"label":"Manufacturer type","value":"VT-TM 0/18 HF","sourceUrl":"https://eshop.weidmueller.com.cn/en/vt-tm-018-hf/p/1716690000/downloads#engineering-support"},{"label":"Available native formats","value":"DWG / DXF / STEP","sourceUrl":"https://eshop.weidmueller.com.cn/en/vt-tm-018-hf/p/1716690000/downloads#engineering-support"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-59d845ce3861dd0b99915358-step","name":"1716690000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://assets.dam.weidmueller.com/assets/api/3098b171-9db1-4874-a818-aafef434ded0/original/1716690000.stp","availability":"direct","sha256":"59d845ce3861dd0b99915358da18b3ea442de0c7b83fbe1974bb69f89e8da817","bytes":56866,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"1716690000.stp.zip","format":"ZIP","sha256":"b0a5e51ade4103d40c9f1a5981ff5ede4519ccaf33332b551401195d0afe74e5","bytes":11275,"includes":["1716690000.stp"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/3098b171-9db1-4874-a818-aafef434ded0/original/1716690000.stp","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1716690000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1716690000/native-59d845ce3861dd0b99915358-step"},{"id":"native-494d08a217e72eb58b0fec6e-zip","name":"1716690000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/e0668268-6560-4b10-af1f-2b0b216fde5d/original/1716690000_DXF.zip","availability":"direct","sha256":"494d08a217e72eb58b0fec6e13ea9f4883e17b96bbfe8dfbcbad4342be64f178","bytes":26204,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"1716690000_DXF.zip","format":"ZIP","sha256":"494d08a217e72eb58b0fec6e13ea9f4883e17b96bbfe8dfbcbad4342be64f178","bytes":26204,"includes":["1716690000_DXF.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/e0668268-6560-4b10-af1f-2b0b216fde5d/original/1716690000_DXF.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["1716690000_back.DXF","1716690000_bottom.DXF","1716690000_front.DXF","1716690000_left.DXF","1716690000_right.DXF","1716690000_top.DXF"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1716690000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1716690000/native-494d08a217e72eb58b0fec6e-zip"},{"id":"native-7be44124e6d632981f3c674b-zip","name":"1716690000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/66a46c1c-44f8-41e5-888c-6cebb492b259/original/1716690000_DWG.zip","availability":"direct","sha256":"7be44124e6d632981f3c674b3d0c55d367cbfaded5ebceae9b7aa33c685501ca","bytes":46616,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"1716690000_DWG.zip","format":"ZIP","sha256":"7be44124e6d632981f3c674b3d0c55d367cbfaded5ebceae9b7aa33c685501ca","bytes":46616,"includes":["1716690000_DWG.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/66a46c1c-44f8-41e5-888c-6cebb492b259/original/1716690000_DWG.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["1716690000_back.DWG","1716690000_bottom.DWG","1716690000_front.DWG","1716690000_left.DWG","1716690000_right.DWG","1716690000_top.DWG"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1716690000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1716690000/native-7be44124e6d632981f3c674b-zip"}],"artifacts":[{"id":"native-59d845ce3861dd0b99915358-step","name":"1716690000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/3098b171-9db1-4874-a818-aafef434ded0/original/1716690000.stp","sourceSha256":"59d845ce3861dd0b99915358da18b3ea442de0c7b83fbe1974bb69f89e8da817","artifactSha256":"b0a5e51ade4103d40c9f1a5981ff5ede4519ccaf33332b551401195d0afe74e5","bytes":11275,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1716690000/native-59d845ce3861dd0b99915358-step","customerPrice":0},{"id":"native-494d08a217e72eb58b0fec6e-zip","name":"1716690000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DXF"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/e0668268-6560-4b10-af1f-2b0b216fde5d/original/1716690000_DXF.zip","sourceSha256":"494d08a217e72eb58b0fec6e13ea9f4883e17b96bbfe8dfbcbad4342be64f178","artifactSha256":"494d08a217e72eb58b0fec6e13ea9f4883e17b96bbfe8dfbcbad4342be64f178","bytes":26204,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1716690000/native-494d08a217e72eb58b0fec6e-zip","customerPrice":0},{"id":"native-7be44124e6d632981f3c674b-zip","name":"1716690000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/66a46c1c-44f8-41e5-888c-6cebb492b259/original/1716690000_DWG.zip","sourceSha256":"7be44124e6d632981f3c674b3d0c55d367cbfaded5ebceae9b7aa33c685501ca","artifactSha256":"7be44124e6d632981f3c674b3d0c55d367cbfaded5ebceae9b7aa33c685501ca","bytes":46616,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1716690000/native-7be44124e6d632981f3c674b-zip","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"VT-TM 0/18 HF — Conductor/Cable marker / Cable coding system, Transparent, Conductor O.D.:1.3 - 2 mm, Polyethylene LD, -40...80 °C"},{"label":"Manufacturer","value":"Weidmüller"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"1716690000"},{"label":"Manufacturer reference","value":"1716690000"},{"label":"Manufacturer type","value":"VT-TM 0/18 HF"},{"label":"Available native formats","value":"DWG / DXF / STEP"},{"label":"Listed file formats","value":"DWG, DXF, STEP"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"2 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 50 files / 512 MiB daily; registered free: 1,000 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/weidmueller-article-1716690000/native-494d08a217e72eb58b0fec6e-zip?asset=2cb5af29ed338ac5bcdec09612ded320fa60e7076730e59d622a7a7e61372080","relatedReferences":[{"name":"Transformer envelope","url":"https://eloragrid.ai/objects/transformer-envelope"},{"name":"Control transformer","url":"https://eloragrid.ai/objects/ga-control-transformer"}],"fileChoiceGuidance":["Start with 1716690000. The files above belong to Weidmüller's VT-TM 0/18 HF — Conductor/Cable marker / Cable coding system, Transparent, Conductor O.D.:1.3 - 2 mm, Polyethylene LD, -40...80 °C resource; match any model or option suffix in the filename to your selected unit.","Available here: STEP, ZIP. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"Conductors carry electrical power or signals between equipment. The drawing marks show which paths connect and which simply pass one another.","example":"In a substation control panel, the wiring diagram lets a technician trace a trip signal from a relay through terminals to the breaker circuit.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Source or sending device","Connected conductors","Receiving equipment"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Weidmüller official source","url":"https://eshop.weidmueller.com.cn/en/vt-tm-018-hf/p/1716690000/downloads#engineering-support"}],"profileId":"wire"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/weidmueller-article-1716690000"}