{"id":"weidmueller-article-1990070000","name":"UR20-2AI-SG-24-DIAG — Field bus, decentralized peripheral - analogue I/O module / Analogue input module (I/O)","manufacturer":"Weidmüller","category":"automation","description":"Weidmüller UR20-2AI-SG-24-DIAG — Field bus, decentralized peripheral - analogue I/O module / Analogue input module (I/O). Manufacturer CAD files for automation equipment selection and layout, identified by article 1990070000.","equipment":["automation","UR20-2AI-SG-24-DIAG — Field bus, decentralized peripheral - analogue I/O module / Analogue input module (I/O)"],"keywords":["Weidmüller","UR20-2AI-SG-24-DIAG — Field bus, decentralized peripheral - analogue I/O module / Analogue input module (I/O)","1990070000","automation","DWG","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"1990070000","sourceUrl":"https://eshop.weidmueller.com.cn/en/ur20-2ai-sg-24-diag/p/1990070000/downloads#engineering-support","officialEvidenceUrl":"https://eshop.weidmueller.com.cn/en/ur20-2ai-sg-24-diag/p/1990070000/downloads#engineering-support","sourcePublisher":"Weidmüller","formats":["DWG","DXF","STEP"],"availability":"direct","accessNote":"Manufacturer CAD files for the listed equipment reference. Open the original files in compatible CAD software.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"1990070000","sourceUrl":"https://eshop.weidmueller.com.cn/en/ur20-2ai-sg-24-diag/p/1990070000/downloads#engineering-support"},{"label":"Manufacturer type","value":"UR20-2AI-SG-24-DIAG","sourceUrl":"https://eshop.weidmueller.com.cn/en/ur20-2ai-sg-24-diag/p/1990070000/downloads#engineering-support"},{"label":"Available native formats","value":"DWG / DXF / STEP","sourceUrl":"https://eshop.weidmueller.com.cn/en/ur20-2ai-sg-24-diag/p/1990070000/downloads#engineering-support"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-92eb2fb33b145d6d774ccdb5-step","name":"1990070000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://assets.dam.weidmueller.com/assets/api/f9e1c501-5a55-482c-8639-5f1d7fe4a213/original/1990070000.stp","availability":"direct","sha256":"92eb2fb33b145d6d774ccdb5685c9b8ba7f97197965099c7527f32b7ea61229e","bytes":1093367,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"1990070000.stp.zip","format":"ZIP","sha256":"df0938ea2249c5084835618d48fe43bacf146b055a3d59c9eb8383e15731cb81","bytes":176646,"includes":["1990070000.stp"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/f9e1c501-5a55-482c-8639-5f1d7fe4a213/original/1990070000.stp","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1990070000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1990070000/native-92eb2fb33b145d6d774ccdb5-step"},{"id":"native-1457b55d64fe4b66b3c9c09e-zip","name":"1990070000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/564ad71c-5e4f-4afa-b2ee-6bfbbf097bf4/original/1990070000_DWG.zip","availability":"direct","sha256":"1457b55d64fe4b66b3c9c09ec7fd728b8e5aa8aa2e22765a0b4b7c3cf720e20b","bytes":61529,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"1990070000_DWG.zip","format":"ZIP","sha256":"1457b55d64fe4b66b3c9c09ec7fd728b8e5aa8aa2e22765a0b4b7c3cf720e20b","bytes":61529,"includes":["1990070000_DWG.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/564ad71c-5e4f-4afa-b2ee-6bfbbf097bf4/original/1990070000_DWG.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["1990070000_back.DWG","1990070000_bottom.DWG","1990070000_front.DWG","1990070000_left.DWG","1990070000_right.DWG","1990070000_top.DWG"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1990070000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1990070000/native-1457b55d64fe4b66b3c9c09e-zip"},{"id":"native-3cf83aa3303c1952665d605f-zip","name":"1990070000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/aaf5fa6c-3c05-4555-8d3e-db460e12c40e/original/1990070000_DXF.zip","availability":"direct","sha256":"3cf83aa3303c1952665d605f1f6bcd36155cae0b1abadbf5438369501e853539","bytes":40592,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"1990070000_DXF.zip","format":"ZIP","sha256":"3cf83aa3303c1952665d605f1f6bcd36155cae0b1abadbf5438369501e853539","bytes":40592,"includes":["1990070000_DXF.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/aaf5fa6c-3c05-4555-8d3e-db460e12c40e/original/1990070000_DXF.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["1990070000_back.DXF","1990070000_bottom.DXF","1990070000_front.DXF","1990070000_left.DXF","1990070000_right.DXF","1990070000_top.DXF"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1990070000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1990070000/native-3cf83aa3303c1952665d605f-zip"}],"artifacts":[{"id":"native-92eb2fb33b145d6d774ccdb5-step","name":"1990070000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/f9e1c501-5a55-482c-8639-5f1d7fe4a213/original/1990070000.stp","sourceSha256":"92eb2fb33b145d6d774ccdb5685c9b8ba7f97197965099c7527f32b7ea61229e","artifactSha256":"df0938ea2249c5084835618d48fe43bacf146b055a3d59c9eb8383e15731cb81","bytes":176646,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1990070000/native-92eb2fb33b145d6d774ccdb5-step","customerPrice":0},{"id":"native-1457b55d64fe4b66b3c9c09e-zip","name":"1990070000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/564ad71c-5e4f-4afa-b2ee-6bfbbf097bf4/original/1990070000_DWG.zip","sourceSha256":"1457b55d64fe4b66b3c9c09ec7fd728b8e5aa8aa2e22765a0b4b7c3cf720e20b","artifactSha256":"1457b55d64fe4b66b3c9c09ec7fd728b8e5aa8aa2e22765a0b4b7c3cf720e20b","bytes":61529,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1990070000/native-1457b55d64fe4b66b3c9c09e-zip","customerPrice":0},{"id":"native-3cf83aa3303c1952665d605f-zip","name":"1990070000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DXF"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/aaf5fa6c-3c05-4555-8d3e-db460e12c40e/original/1990070000_DXF.zip","sourceSha256":"3cf83aa3303c1952665d605f1f6bcd36155cae0b1abadbf5438369501e853539","artifactSha256":"3cf83aa3303c1952665d605f1f6bcd36155cae0b1abadbf5438369501e853539","bytes":40592,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1990070000/native-3cf83aa3303c1952665d605f-zip","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"UR20-2AI-SG-24-DIAG — Field bus, decentralized peripheral - analogue I/O module / Analogue input module (I/O)"},{"label":"Manufacturer","value":"Weidmüller"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"1990070000"},{"label":"Manufacturer reference","value":"1990070000"},{"label":"Manufacturer type","value":"UR20-2AI-SG-24-DIAG"},{"label":"Available native formats","value":"DWG / DXF / STEP"},{"label":"Listed file formats","value":"DWG, DXF, STEP"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"2 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 50 files / 512 MiB daily; registered free: up to 60 individual files/formats per 24 hours from first admission, subject to 1 GiB/UTC day and shared 10 GiB/day or lower delivery safeguards; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/weidmueller-article-1990070000/native-1457b55d64fe4b66b3c9c09e-zip?asset=99b5143c374f9ceeba8ecc4d0530c9f9ffab88a3b654548b9744470155ece5a5","relatedReferences":[{"name":"PLC CPU module","url":"https://eloragrid.ai/objects/ga-plc-cpu-module"},{"name":"HMI touchscreen","url":"https://eloragrid.ai/objects/ga-hmi-touchscreen"}],"fileChoiceGuidance":["Start with 1990070000. The files above belong to Weidmüller's UR20-2AI-SG-24-DIAG — Field bus, decentralized peripheral - analogue I/O module / Analogue input module (I/O) resource; match any model or option suffix in the filename to your selected unit.","Available here: STEP, ZIP. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"An input/output assembly connects field devices to a controller. Inputs report measurements or status; outputs pass the controller's commands to equipment.","example":"In a switchroom, a remote I/O station can collect fan-status contacts and send ventilation-control commands without every signal returning to the main controller rack.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Field signals","Input and output assembly","Controller information and commands"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Weidmüller official source","url":"https://eshop.weidmueller.com.cn/en/ur20-2ai-sg-24-diag/p/1990070000/downloads#engineering-support"}],"profileId":"plc-combined"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/weidmueller-article-1990070000"}