{"id":"weidmueller-article-1992260000","name":"AIO21 1.5 SI — Sensor/actor terminal block / Initiator/actuator terminal, PUSH IN, 1.5 mm², 250 V, 13.5 A, Number of connections: 4, dark beige","manufacturer":"Weidmüller","category":"wiring","description":"Weidmüller AIO21 1.5 SI — Sensor/actor terminal block / Initiator/actuator terminal, PUSH IN, 1.5 mm², 250 V, 13.5 A, Number of connections: 4, dark beige. Manufacturer CAD files for wiring equipment selection and layout, identified by article 1992260000.","equipment":["wiring","AIO21 1.5 SI — Sensor/actor terminal block / Initiator/actuator terminal, PUSH IN, 1.5 mm², 250 V, 13.5 A, Number of connections: 4, dark beige"],"keywords":["Weidmüller","AIO21 1.5 SI — Sensor/actor terminal block / Initiator/actuator terminal, PUSH IN, 1.5 mm², 250 V, 13.5 A, Number of connections: 4, dark beige","1992260000","wiring","DWG","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"1992260000","sourceUrl":"https://eshop.weidmueller.com.cn/en/aio21-1-5-si/p/1992260000/downloads#engineering-support","officialEvidenceUrl":"https://eshop.weidmueller.com.cn/en/aio21-1-5-si/p/1992260000/downloads#engineering-support","sourcePublisher":"Weidmüller","formats":["DWG","DXF","STEP"],"availability":"direct","accessNote":"Manufacturer CAD files for the listed equipment reference. Open the original files in compatible CAD software.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"1992260000","sourceUrl":"https://eshop.weidmueller.com.cn/en/aio21-1-5-si/p/1992260000/downloads#engineering-support"},{"label":"Manufacturer type","value":"AIO21 1.5 SI","sourceUrl":"https://eshop.weidmueller.com.cn/en/aio21-1-5-si/p/1992260000/downloads#engineering-support"},{"label":"Available native formats","value":"DWG / DXF / STEP","sourceUrl":"https://eshop.weidmueller.com.cn/en/aio21-1-5-si/p/1992260000/downloads#engineering-support"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-6cac12e6620994006900339d-step","name":"1992260000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://assets.dam.weidmueller.com/assets/api/8eeaf1f6-70e8-41db-8853-96b2f19692c8/original/1992260000.stp","availability":"direct","sha256":"6cac12e6620994006900339d3d5ec11d34c1dd655f090eb733d10c898c369f2d","bytes":1184125,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"1992260000.stp.zip","format":"ZIP","sha256":"40d49f9124ad83a65bbdf6ea264714db3f37c8be594177a6325fc9db57b69477","bytes":203049,"includes":["1992260000.stp"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/8eeaf1f6-70e8-41db-8853-96b2f19692c8/original/1992260000.stp","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1992260000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1992260000/native-6cac12e6620994006900339d-step"},{"id":"native-e75433eda7f8764fcfe9bd73-zip","name":"1992260000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/61aa3e52-912f-47d9-8142-3978a540c91f/original/1992260000_DXF.zip","availability":"direct","sha256":"e75433eda7f8764fcfe9bd73701eba2750755af99e92e1590a149231a9b581b6","bytes":95383,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"1992260000_DXF.zip","format":"ZIP","sha256":"e75433eda7f8764fcfe9bd73701eba2750755af99e92e1590a149231a9b581b6","bytes":95383,"includes":["1992260000_DXF.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/61aa3e52-912f-47d9-8142-3978a540c91f/original/1992260000_DXF.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["1992260000_back.DXF","1992260000_bottom.DXF","1992260000_front.DXF","1992260000_left.DXF","1992260000_right.DXF","1992260000_top.DXF"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1992260000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1992260000/native-e75433eda7f8764fcfe9bd73-zip"},{"id":"native-2ba0ce74a9fc54f684d71449-zip","name":"1992260000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/80fd449f-da6e-452b-9cdd-8abc6d24afcb/original/1992260000_DWG.zip","availability":"direct","sha256":"2ba0ce74a9fc54f684d71449df6e48425293e0523265ef9614f98d05c72cf740","bytes":105412,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"1992260000_DWG.zip","format":"ZIP","sha256":"2ba0ce74a9fc54f684d71449df6e48425293e0523265ef9614f98d05c72cf740","bytes":105412,"includes":["1992260000_DWG.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/80fd449f-da6e-452b-9cdd-8abc6d24afcb/original/1992260000_DWG.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["1992260000_back.DWG","1992260000_bottom.DWG","1992260000_front.DWG","1992260000_left.DWG","1992260000_right.DWG","1992260000_top.DWG"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1992260000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1992260000/native-2ba0ce74a9fc54f684d71449-zip"}],"artifacts":[{"id":"native-6cac12e6620994006900339d-step","name":"1992260000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/8eeaf1f6-70e8-41db-8853-96b2f19692c8/original/1992260000.stp","sourceSha256":"6cac12e6620994006900339d3d5ec11d34c1dd655f090eb733d10c898c369f2d","artifactSha256":"40d49f9124ad83a65bbdf6ea264714db3f37c8be594177a6325fc9db57b69477","bytes":203049,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1992260000/native-6cac12e6620994006900339d-step","customerPrice":0},{"id":"native-e75433eda7f8764fcfe9bd73-zip","name":"1992260000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DXF"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/61aa3e52-912f-47d9-8142-3978a540c91f/original/1992260000_DXF.zip","sourceSha256":"e75433eda7f8764fcfe9bd73701eba2750755af99e92e1590a149231a9b581b6","artifactSha256":"e75433eda7f8764fcfe9bd73701eba2750755af99e92e1590a149231a9b581b6","bytes":95383,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1992260000/native-e75433eda7f8764fcfe9bd73-zip","customerPrice":0},{"id":"native-2ba0ce74a9fc54f684d71449-zip","name":"1992260000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/80fd449f-da6e-452b-9cdd-8abc6d24afcb/original/1992260000_DWG.zip","sourceSha256":"2ba0ce74a9fc54f684d71449df6e48425293e0523265ef9614f98d05c72cf740","artifactSha256":"2ba0ce74a9fc54f684d71449df6e48425293e0523265ef9614f98d05c72cf740","bytes":105412,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1992260000/native-2ba0ce74a9fc54f684d71449-zip","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"AIO21 1.5 SI — Sensor/actor terminal block / Initiator/actuator terminal, PUSH IN, 1.5 mm², 250 V, 13.5 A, Number of connections: 4, dark beige"},{"label":"Manufacturer","value":"Weidmüller"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"1992260000"},{"label":"Manufacturer reference","value":"1992260000"},{"label":"Manufacturer type","value":"AIO21 1.5 SI"},{"label":"Available native formats","value":"DWG / DXF / STEP"},{"label":"Listed file formats","value":"DWG, DXF, STEP"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"2 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 50 files / 512 MiB daily; registered free: 1,000 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/weidmueller-article-1992260000/native-e75433eda7f8764fcfe9bd73-zip?asset=877e76de63cb8010c9a674d2747e6797b04e587cbae1a3906728a00e3382311f","relatedReferences":[{"name":"Terminal strip assembly","url":"https://eloragrid.ai/objects/terminal-strip"},{"name":"Cable gland","url":"https://eloragrid.ai/objects/ga-cable-gland"}],"fileChoiceGuidance":["Start with 1992260000. The files above belong to Weidmüller's AIO21 1.5 SI — Sensor/actor terminal block / Initiator/actuator terminal, PUSH IN, 1.5 mm², 250 V, 13.5 A, Number of connections: 4, dark beige resource; match any model or option suffix in the filename to your selected unit.","Available here: STEP, ZIP. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"A terminal provides an identified point for joining wires to equipment or to other wires. Terminal strips organise those connections so they can be wired and checked.","example":"In a substation relay panel, numbered terminals connect the switchyard cables to the protection and control equipment.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Field wiring","Identified terminal connections","Panel equipment"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Weidmüller official source","url":"https://eshop.weidmueller.com.cn/en/aio21-1-5-si/p/1992260000/downloads#engineering-support"}],"profileId":"terminal"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/weidmueller-article-1992260000"}