{"id":"weidmueller-article-2007420000","name":"UR20-3EM-230V-AC — Field bus, decentralized peripheral - function-/technology module / Function module (I/O)","manufacturer":"Weidmüller","category":"automation","description":"Weidmüller UR20-3EM-230V-AC — Field bus, decentralized peripheral - function-/technology module / Function module (I/O). Manufacturer CAD files for automation equipment selection and layout, identified by article 2007420000.","equipment":["automation","UR20-3EM-230V-AC — Field bus, decentralized peripheral - function-/technology module / Function module (I/O)"],"keywords":["Weidmüller","UR20-3EM-230V-AC — Field bus, decentralized peripheral - function-/technology module / Function module (I/O)","2007420000","automation","DWG","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"2007420000","sourceUrl":"https://eshop.weidmueller.com.cn/en/ur20-3em-230v-ac/p/2007420000/downloads#engineering-support","officialEvidenceUrl":"https://eshop.weidmueller.com.cn/en/ur20-3em-230v-ac/p/2007420000/downloads#engineering-support","sourcePublisher":"Weidmüller","formats":["DWG","DXF","STEP"],"availability":"direct","accessNote":"Manufacturer CAD files for the listed equipment reference. Open the original files in compatible CAD software.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"2007420000","sourceUrl":"https://eshop.weidmueller.com.cn/en/ur20-3em-230v-ac/p/2007420000/downloads#engineering-support"},{"label":"Manufacturer type","value":"UR20-3EM-230V-AC","sourceUrl":"https://eshop.weidmueller.com.cn/en/ur20-3em-230v-ac/p/2007420000/downloads#engineering-support"},{"label":"Available native formats","value":"DWG / DXF / STEP","sourceUrl":"https://eshop.weidmueller.com.cn/en/ur20-3em-230v-ac/p/2007420000/downloads#engineering-support"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-2938474129bf59f81288f03e-step","name":"2007420000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://assets.dam.weidmueller.com/assets/api/b0afbe4d-6d1b-422c-a9d3-f8fc2148b4db/original/2007420000.stp","availability":"direct","sha256":"2938474129bf59f81288f03e0402af31e13ee377a36806256c45c9fb98a7a393","bytes":4061391,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"2007420000.stp.zip","format":"ZIP","sha256":"6060ef6c1b4b437aea4b020088f77c44c0092b2a12a1dc6202a83d87981ae5be","bytes":652047,"includes":["2007420000.stp"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/b0afbe4d-6d1b-422c-a9d3-f8fc2148b4db/original/2007420000.stp","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2007420000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2007420000/native-2938474129bf59f81288f03e-step"},{"id":"native-b41bc39dcc56d14bedf83f34-zip","name":"2007420000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/ff5a3ce2-28ae-4004-99db-e5c16e00af66/original/2007420000_DXF.zip","availability":"direct","sha256":"b41bc39dcc56d14bedf83f34e86593ca9adc8e92ffbfb0b6bfa9c5c87ff380b4","bytes":70396,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"2007420000_DXF.zip","format":"ZIP","sha256":"b41bc39dcc56d14bedf83f34e86593ca9adc8e92ffbfb0b6bfa9c5c87ff380b4","bytes":70396,"includes":["2007420000_DXF.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/ff5a3ce2-28ae-4004-99db-e5c16e00af66/original/2007420000_DXF.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["2007420000_back.DXF","2007420000_bottom.DXF","2007420000_front.DXF","2007420000_left.DXF","2007420000_right.DXF","2007420000_top.DXF"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2007420000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2007420000/native-b41bc39dcc56d14bedf83f34-zip"},{"id":"native-98f5edf50f30f6d34ee1ba9c-zip","name":"2007420000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/09e7aaf6-5cba-4947-b2d4-6fd1b827e32a/original/2007420000_DWG.zip","availability":"direct","sha256":"98f5edf50f30f6d34ee1ba9c7de419d3d3243e41b5cef68759b3b7e6f5bbd5a8","bytes":93140,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"2007420000_DWG.zip","format":"ZIP","sha256":"98f5edf50f30f6d34ee1ba9c7de419d3d3243e41b5cef68759b3b7e6f5bbd5a8","bytes":93140,"includes":["2007420000_DWG.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/09e7aaf6-5cba-4947-b2d4-6fd1b827e32a/original/2007420000_DWG.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["2007420000_back.DWG","2007420000_bottom.DWG","2007420000_front.DWG","2007420000_left.DWG","2007420000_right.DWG","2007420000_top.DWG"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2007420000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2007420000/native-98f5edf50f30f6d34ee1ba9c-zip"}],"artifacts":[{"id":"native-2938474129bf59f81288f03e-step","name":"2007420000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/b0afbe4d-6d1b-422c-a9d3-f8fc2148b4db/original/2007420000.stp","sourceSha256":"2938474129bf59f81288f03e0402af31e13ee377a36806256c45c9fb98a7a393","artifactSha256":"6060ef6c1b4b437aea4b020088f77c44c0092b2a12a1dc6202a83d87981ae5be","bytes":652047,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2007420000/native-2938474129bf59f81288f03e-step","customerPrice":0},{"id":"native-b41bc39dcc56d14bedf83f34-zip","name":"2007420000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DXF"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/ff5a3ce2-28ae-4004-99db-e5c16e00af66/original/2007420000_DXF.zip","sourceSha256":"b41bc39dcc56d14bedf83f34e86593ca9adc8e92ffbfb0b6bfa9c5c87ff380b4","artifactSha256":"b41bc39dcc56d14bedf83f34e86593ca9adc8e92ffbfb0b6bfa9c5c87ff380b4","bytes":70396,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2007420000/native-b41bc39dcc56d14bedf83f34-zip","customerPrice":0},{"id":"native-98f5edf50f30f6d34ee1ba9c-zip","name":"2007420000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/09e7aaf6-5cba-4947-b2d4-6fd1b827e32a/original/2007420000_DWG.zip","sourceSha256":"98f5edf50f30f6d34ee1ba9c7de419d3d3243e41b5cef68759b3b7e6f5bbd5a8","artifactSha256":"98f5edf50f30f6d34ee1ba9c7de419d3d3243e41b5cef68759b3b7e6f5bbd5a8","bytes":93140,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2007420000/native-98f5edf50f30f6d34ee1ba9c-zip","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"UR20-3EM-230V-AC — Field bus, decentralized peripheral - function-/technology module / Function module (I/O)"},{"label":"Manufacturer","value":"Weidmüller"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"2007420000"},{"label":"Manufacturer reference","value":"2007420000"},{"label":"Manufacturer type","value":"UR20-3EM-230V-AC"},{"label":"Available native formats","value":"DWG / DXF / STEP"},{"label":"Listed file formats","value":"DWG, DXF, STEP"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"2 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 3 files / 25 MiB daily; registered free: 100 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/weidmueller-article-2007420000/native-b41bc39dcc56d14bedf83f34-zip?asset=23261f2eb990d52f88cc1cb7c36b65f2d174b2ffa819b5bb0019470a063e55c6","relatedReferences":[{"name":"PLC CPU module","url":"https://eloragrid.ai/objects/ga-plc-cpu-module"},{"name":"HMI touchscreen","url":"https://eloragrid.ai/objects/ga-hmi-touchscreen"}],"fileChoiceGuidance":["Start with 2007420000. The files above belong to Weidmüller's UR20-3EM-230V-AC — Field bus, decentralized peripheral - function-/technology module / Function module (I/O) resource; match any model or option suffix in the filename to your selected unit.","Available here: STEP, ZIP. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"An input/output assembly connects field devices to a controller. Inputs report measurements or status; outputs pass the controller's commands to equipment.","example":"In a switchroom, a remote I/O station can collect fan-status contacts and send ventilation-control commands without every signal returning to the main controller rack.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Field signals","Input and output assembly","Controller information and commands"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Weidmüller official source","url":"https://eshop.weidmueller.com.cn/en/ur20-3em-230v-ac/p/2007420000/downloads#engineering-support"}],"profileId":"plc-combined"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/weidmueller-article-2007420000"}