{"id":"weidmueller-article-2153570000","name":"TRS 120VUC 1CO AGSNO — Standard all-or-nothing relay / Relay module, 120 V UC ±10 %, Green LED, 1 CO contact (AgSnO) , 250 V AC, 6 A, Screw connection","manufacturer":"Weidmüller","category":"protection","description":"Weidmüller TRS 120VUC 1CO AGSNO — Standard all-or-nothing relay / Relay module, 120 V UC ±10 %, Green LED, 1 CO contact (AgSnO) , 250 V AC, 6 A, Screw connection. Manufacturer CAD files for protection equipment selection and layout, identified by article 2153570000.","equipment":["protection","TRS 120VUC 1CO AGSNO — Standard all-or-nothing relay / Relay module, 120 V UC ±10 %, Green LED, 1 CO contact (AgSnO) , 250 V AC, 6 A, Screw connection"],"keywords":["Weidmüller","TRS 120VUC 1CO AGSNO — Standard all-or-nothing relay / Relay module, 120 V UC ±10 %, Green LED, 1 CO contact (AgSnO) , 250 V AC, 6 A, Screw connection","2153570000","protection","DWG","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"2153570000","sourceUrl":"https://eshop.weidmueller.com.cn/en/trs-120vuc-1co-agsno/p/2153570000/downloads#engineering-support","officialEvidenceUrl":"https://eshop.weidmueller.com.cn/en/trs-120vuc-1co-agsno/p/2153570000/downloads#engineering-support","sourcePublisher":"Weidmüller","formats":["DWG","DXF","STEP"],"availability":"direct","accessNote":"Manufacturer CAD files for the listed equipment reference. Open the original files in compatible CAD software.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"2153570000","sourceUrl":"https://eshop.weidmueller.com.cn/en/trs-120vuc-1co-agsno/p/2153570000/downloads#engineering-support"},{"label":"Manufacturer type","value":"TRS 120VUC 1CO AGSNO","sourceUrl":"https://eshop.weidmueller.com.cn/en/trs-120vuc-1co-agsno/p/2153570000/downloads#engineering-support"},{"label":"Available native formats","value":"DWG / DXF / STEP","sourceUrl":"https://eshop.weidmueller.com.cn/en/trs-120vuc-1co-agsno/p/2153570000/downloads#engineering-support"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-6eb9f7160da38cb973d37b18-step","name":"2153570000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://assets.dam.weidmueller.com/assets/api/0ba487f4-6101-4164-a285-986fca400ffe/original/2153570000.stp","availability":"direct","sha256":"6eb9f7160da38cb973d37b18bd00c5425d7673c0dfa8638dd418b4fb873f1777","bytes":976945,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"2153570000.stp.zip","format":"ZIP","sha256":"a48a06c2f1799ff38c4839c9f57865f81e9cb3009a9604c2a7976f57e14b0a58","bytes":172452,"includes":["2153570000.stp"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/0ba487f4-6101-4164-a285-986fca400ffe/original/2153570000.stp","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2153570000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2153570000/native-6eb9f7160da38cb973d37b18-step"},{"id":"native-9eca8a60a3d1a19607b0835e-zip","name":"2153570000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/080e6d88-7c0d-455b-b59b-668111f3afbb/original/2153570000_DWG.zip","availability":"direct","sha256":"9eca8a60a3d1a19607b0835ef3b1aaf5bb270d926783a64b1e9072a57d36c1b3","bytes":125789,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"2153570000_DWG.zip","format":"ZIP","sha256":"9eca8a60a3d1a19607b0835ef3b1aaf5bb270d926783a64b1e9072a57d36c1b3","bytes":125789,"includes":["2153570000_DWG.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/080e6d88-7c0d-455b-b59b-668111f3afbb/original/2153570000_DWG.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["2153570000_back.DWG","2153570000_bottom.DWG","2153570000_front.DWG","2153570000_left.DWG","2153570000_right.DWG","2153570000_top.DWG"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2153570000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2153570000/native-9eca8a60a3d1a19607b0835e-zip"},{"id":"native-3a172eefee712db676fd0703-zip","name":"2153570000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/b42842d5-1a39-4959-b0d7-167f3af97fac/original/2153570000_DXF.zip","availability":"direct","sha256":"3a172eefee712db676fd0703b0cbdff643085068f0ce5c69d3e5db340afd1fc1","bytes":101047,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"2153570000_DXF.zip","format":"ZIP","sha256":"3a172eefee712db676fd0703b0cbdff643085068f0ce5c69d3e5db340afd1fc1","bytes":101047,"includes":["2153570000_DXF.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/b42842d5-1a39-4959-b0d7-167f3af97fac/original/2153570000_DXF.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["2153570000_back.DXF","2153570000_bottom.DXF","2153570000_front.DXF","2153570000_left.DXF","2153570000_right.DXF","2153570000_top.DXF"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2153570000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2153570000/native-3a172eefee712db676fd0703-zip"}],"artifacts":[{"id":"native-6eb9f7160da38cb973d37b18-step","name":"2153570000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/0ba487f4-6101-4164-a285-986fca400ffe/original/2153570000.stp","sourceSha256":"6eb9f7160da38cb973d37b18bd00c5425d7673c0dfa8638dd418b4fb873f1777","artifactSha256":"a48a06c2f1799ff38c4839c9f57865f81e9cb3009a9604c2a7976f57e14b0a58","bytes":172452,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2153570000/native-6eb9f7160da38cb973d37b18-step","customerPrice":0},{"id":"native-9eca8a60a3d1a19607b0835e-zip","name":"2153570000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/080e6d88-7c0d-455b-b59b-668111f3afbb/original/2153570000_DWG.zip","sourceSha256":"9eca8a60a3d1a19607b0835ef3b1aaf5bb270d926783a64b1e9072a57d36c1b3","artifactSha256":"9eca8a60a3d1a19607b0835ef3b1aaf5bb270d926783a64b1e9072a57d36c1b3","bytes":125789,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2153570000/native-9eca8a60a3d1a19607b0835e-zip","customerPrice":0},{"id":"native-3a172eefee712db676fd0703-zip","name":"2153570000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DXF"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/b42842d5-1a39-4959-b0d7-167f3af97fac/original/2153570000_DXF.zip","sourceSha256":"3a172eefee712db676fd0703b0cbdff643085068f0ce5c69d3e5db340afd1fc1","artifactSha256":"3a172eefee712db676fd0703b0cbdff643085068f0ce5c69d3e5db340afd1fc1","bytes":101047,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2153570000/native-3a172eefee712db676fd0703-zip","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"TRS 120VUC 1CO AGSNO — Standard all-or-nothing relay / Relay module, 120 V UC ±10 %, Green LED, 1 CO contact (AgSnO) , 250 V AC, 6 A, Screw connection"},{"label":"Manufacturer","value":"Weidmüller"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"2153570000"},{"label":"Manufacturer reference","value":"2153570000"},{"label":"Manufacturer type","value":"TRS 120VUC 1CO AGSNO"},{"label":"Available native formats","value":"DWG / DXF / STEP"},{"label":"Listed file formats","value":"DWG, DXF, STEP"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"2 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 50 files / 512 MiB daily; registered free: 1,000 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/weidmueller-article-2153570000/native-9eca8a60a3d1a19607b0835e-zip?asset=1aa90f8f221b04239b148f3bfff148fb20056197fe294515f1e9846827425c5a","relatedReferences":[{"name":"Protection relay IED","url":"https://eloragrid.ai/objects/ga-protection-relay-ied"},{"name":"Power quality meter","url":"https://eloragrid.ai/objects/ga-power-quality-meter"}],"fileChoiceGuidance":["Start with 2153570000. The files above belong to Weidmüller's TRS 120VUC 1CO AGSNO — Standard all-or-nothing relay / Relay module, 120 V UC ±10 %, Green LED, 1 CO contact (AgSnO) , 250 V AC, 6 A, Screw connection resource; match any model or option suffix in the filename to your selected unit.","Available here: STEP, ZIP. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"An LED produces light when operated with the appropriate electrical current. It is commonly used to indicate an electronic device's state.","example":"On a switchgear control module, an LED can show that an input is active or that the module has power.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Electrical indication signal","LED","Visible indication"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Weidmüller official source","url":"https://eshop.weidmueller.com.cn/en/trs-120vuc-1co-agsno/p/2153570000/downloads#engineering-support"}],"profileId":"led"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/weidmueller-article-2153570000"}