{"id":"weidmueller-article-2489680000","name":"ACT20P-CI-CO-P — Input isolator / Signal converter/insulator, Signal converter/isolator, HART®, Input: 0(4)-20 mA, Output: 0(4)-20 mA","manufacturer":"Weidmüller","category":"transformers","description":"Weidmüller ACT20P-CI-CO-P — Input isolator / Signal converter/insulator, Signal converter/isolator, HART®, Input: 0(4)-20 mA, Output: 0(4)-20 mA. Manufacturer CAD files for transformers equipment selection and layout, identified by article 2489680000.","equipment":["transformers","ACT20P-CI-CO-P — Input isolator / Signal converter/insulator, Signal converter/isolator, HART®, Input: 0(4)-20 mA, Output: 0(4)-20 mA"],"keywords":["Weidmüller","ACT20P-CI-CO-P — Input isolator / Signal converter/insulator, Signal converter/isolator, HART®, Input: 0(4)-20 mA, Output: 0(4)-20 mA","2489680000","transformers","DWG","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"2489680000","sourceUrl":"https://eshop.weidmueller.com.cn/en/act20p-ci-co-p/p/2489680000/downloads#engineering-support","officialEvidenceUrl":"https://eshop.weidmueller.com.cn/en/act20p-ci-co-p/p/2489680000/downloads#engineering-support","sourcePublisher":"Weidmüller","formats":["DWG","DXF","STEP"],"availability":"direct","accessNote":"Manufacturer CAD files for the listed equipment reference. Open the original files in compatible CAD software.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"2489680000","sourceUrl":"https://eshop.weidmueller.com.cn/en/act20p-ci-co-p/p/2489680000/downloads#engineering-support"},{"label":"Manufacturer type","value":"ACT20P-CI-CO-P","sourceUrl":"https://eshop.weidmueller.com.cn/en/act20p-ci-co-p/p/2489680000/downloads#engineering-support"},{"label":"Available native formats","value":"DWG / DXF / STEP","sourceUrl":"https://eshop.weidmueller.com.cn/en/act20p-ci-co-p/p/2489680000/downloads#engineering-support"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-61e3e45b5e237fe12ccbf455-zip","name":"2489680000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/2665c58d-0503-47f3-86ac-6d997fd7ca5f/original/2489680000_DWG.zip","availability":"direct","sha256":"61e3e45b5e237fe12ccbf455fc641f253acafc1e776ed9e4ed1befd7da601925","bytes":146318,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"2489680000_DWG.zip","format":"ZIP","sha256":"61e3e45b5e237fe12ccbf455fc641f253acafc1e776ed9e4ed1befd7da601925","bytes":146318,"includes":["2489680000_DWG.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/2665c58d-0503-47f3-86ac-6d997fd7ca5f/original/2489680000_DWG.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["2489680000_back.DWG","2489680000_bottom.DWG","2489680000_front.DWG","2489680000_left.DWG","2489680000_right.DWG","2489680000_top.DWG"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2489680000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2489680000/native-61e3e45b5e237fe12ccbf455-zip"},{"id":"native-505a5d60d1df3c0e5067d561-zip","name":"2489680000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/ba181313-05b8-4405-9399-a915dcb8a1ee/original/2489680000_DXF.zip","availability":"direct","sha256":"505a5d60d1df3c0e5067d56136bd9567c4f218d4dbf73e2afffe2b62ae512328","bytes":110570,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"2489680000_DXF.zip","format":"ZIP","sha256":"505a5d60d1df3c0e5067d56136bd9567c4f218d4dbf73e2afffe2b62ae512328","bytes":110570,"includes":["2489680000_DXF.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/ba181313-05b8-4405-9399-a915dcb8a1ee/original/2489680000_DXF.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["2489680000_back.DXF","2489680000_bottom.DXF","2489680000_front.DXF","2489680000_left.DXF","2489680000_right.DXF","2489680000_top.DXF"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2489680000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2489680000/native-505a5d60d1df3c0e5067d561-zip"},{"id":"native-b45f43f4c0baa829f5397d72-step","name":"2489680000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://assets.dam.weidmueller.com/assets/api/600bf589-948d-4221-a0b7-33ed59d93578/original/2489680000.stp","availability":"direct","sha256":"b45f43f4c0baa829f5397d725d6745a19f850dca90bb2cde931361125069d682","bytes":3253244,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"2489680000.stp.zip","format":"ZIP","sha256":"9a87cd9c130b16c780a6556995f62eaa5e4067100a98b38d0b09bb60f7479b51","bytes":530006,"includes":["2489680000.stp"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/600bf589-948d-4221-a0b7-33ed59d93578/original/2489680000.stp","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2489680000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2489680000/native-b45f43f4c0baa829f5397d72-step"}],"artifacts":[{"id":"native-61e3e45b5e237fe12ccbf455-zip","name":"2489680000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/2665c58d-0503-47f3-86ac-6d997fd7ca5f/original/2489680000_DWG.zip","sourceSha256":"61e3e45b5e237fe12ccbf455fc641f253acafc1e776ed9e4ed1befd7da601925","artifactSha256":"61e3e45b5e237fe12ccbf455fc641f253acafc1e776ed9e4ed1befd7da601925","bytes":146318,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2489680000/native-61e3e45b5e237fe12ccbf455-zip","customerPrice":0},{"id":"native-505a5d60d1df3c0e5067d561-zip","name":"2489680000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DXF"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/ba181313-05b8-4405-9399-a915dcb8a1ee/original/2489680000_DXF.zip","sourceSha256":"505a5d60d1df3c0e5067d56136bd9567c4f218d4dbf73e2afffe2b62ae512328","artifactSha256":"505a5d60d1df3c0e5067d56136bd9567c4f218d4dbf73e2afffe2b62ae512328","bytes":110570,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2489680000/native-505a5d60d1df3c0e5067d561-zip","customerPrice":0},{"id":"native-b45f43f4c0baa829f5397d72-step","name":"2489680000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/600bf589-948d-4221-a0b7-33ed59d93578/original/2489680000.stp","sourceSha256":"b45f43f4c0baa829f5397d725d6745a19f850dca90bb2cde931361125069d682","artifactSha256":"9a87cd9c130b16c780a6556995f62eaa5e4067100a98b38d0b09bb60f7479b51","bytes":530006,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2489680000/native-b45f43f4c0baa829f5397d72-step","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"ACT20P-CI-CO-P — Input isolator / Signal converter/insulator, Signal converter/isolator, HART®, Input: 0(4)-20 mA, Output: 0(4)-20 mA"},{"label":"Manufacturer","value":"Weidmüller"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"2489680000"},{"label":"Manufacturer reference","value":"2489680000"},{"label":"Manufacturer type","value":"ACT20P-CI-CO-P"},{"label":"Available native formats","value":"DWG / DXF / STEP"},{"label":"Listed file formats","value":"DWG, DXF, STEP"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"2 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 3 files / 25 MiB daily; registered free: 100 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/weidmueller-article-2489680000/native-61e3e45b5e237fe12ccbf455-zip?asset=bc19791528b594b8c606a0c5b8b4fd2f5e71bc9aa267bc4acbf3709a55cf2f0d","relatedReferences":[{"name":"Transformer envelope","url":"https://eloragrid.ai/objects/transformer-envelope"},{"name":"Control transformer","url":"https://eloragrid.ai/objects/ga-control-transformer"}],"fileChoiceGuidance":["Start with 2489680000. The files above belong to Weidmüller's ACT20P-CI-CO-P — Input isolator / Signal converter/insulator, Signal converter/isolator, HART®, Input: 0(4)-20 mA, Output: 0(4)-20 mA resource; match any model or option suffix in the filename to your selected unit.","Available here: ZIP, STEP. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"A transformer transfers electrical energy between coils of wire, commonly to change an AC supply from one voltage to another.","example":"In a microgrid substation, a transformer can connect a lower-voltage generator or inverter system to a higher-voltage distribution network.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["AC supply","Transformer","Supply at the required voltage"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Weidmüller official source","url":"https://eshop.weidmueller.com.cn/en/act20p-ci-co-p/p/2489680000/downloads#engineering-support"}],"profileId":"transformer"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/weidmueller-article-2489680000"}