{"id":"weidmueller-article-2502320000","name":"ALO 16 BL — Feed-through terminal block / Supply terminal, PUSH IN, blue, 16 mm², 76 A, 800 V, Number of connections: 2, Number of levels: 1, TS 35, V-0, Wemid","manufacturer":"Weidmüller","category":"wiring","description":"Weidmüller ALO 16 BL — Feed-through terminal block / Supply terminal, PUSH IN, blue, 16 mm², 76 A, 800 V, Number of connections: 2, Number of levels: 1, TS 35, V-0, Wemid. Manufacturer CAD files for wiring equipment selection and layout, identified by article 2502320000.","equipment":["wiring","ALO 16 BL — Feed-through terminal block / Supply terminal, PUSH IN, blue, 16 mm², 76 A, 800 V, Number of connections: 2, Number of levels: 1, TS 35, V-0, Wemid"],"keywords":["Weidmüller","ALO 16 BL — Feed-through terminal block / Supply terminal, PUSH IN, blue, 16 mm², 76 A, 800 V, Number of connections: 2, Number of levels: 1, TS 35, V-0, Wemid","2502320000","wiring","DWG","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"2502320000","sourceUrl":"https://eshop.weidmueller.com.cn/en/alo-16-bl/p/2502320000/downloads#engineering-support","officialEvidenceUrl":"https://eshop.weidmueller.com.cn/en/alo-16-bl/p/2502320000/downloads#engineering-support","sourcePublisher":"Weidmüller","formats":["DWG","DXF","STEP"],"availability":"direct","accessNote":"Manufacturer CAD files for the listed equipment reference. Open the original files in compatible CAD software.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"2502320000","sourceUrl":"https://eshop.weidmueller.com.cn/en/alo-16-bl/p/2502320000/downloads#engineering-support"},{"label":"Manufacturer type","value":"ALO 16 BL","sourceUrl":"https://eshop.weidmueller.com.cn/en/alo-16-bl/p/2502320000/downloads#engineering-support"},{"label":"Available native formats","value":"DWG / DXF / STEP","sourceUrl":"https://eshop.weidmueller.com.cn/en/alo-16-bl/p/2502320000/downloads#engineering-support"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-4eca6b465e8e1ef4816ed348-step","name":"2502320000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://assets.dam.weidmueller.com/assets/api/61daaa9e-d354-4d11-9321-3dc6f8c4e61a/original/2502320000.stp","availability":"direct","sha256":"4eca6b465e8e1ef4816ed348abbcbda75e55f66814f40894f8aef22e032600b6","bytes":707009,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"2502320000.stp.zip","format":"ZIP","sha256":"84d22940b1d73f5a49f1808443119030db551b4c6e35fdffce7708cdb73b7f26","bytes":124587,"includes":["2502320000.stp"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/61daaa9e-d354-4d11-9321-3dc6f8c4e61a/original/2502320000.stp","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2502320000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2502320000/native-4eca6b465e8e1ef4816ed348-step"},{"id":"native-2d51684c0a10d450ce2ddb9c-zip","name":"2502320000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/c431ed1c-41f2-41a5-8de7-03a4d6b6c5fc/original/2502320000_DXF.zip","availability":"direct","sha256":"2d51684c0a10d450ce2ddb9cc2b0cfc769857b9a817c9447d1de51a9bc323e96","bytes":48000,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"2502320000_DXF.zip","format":"ZIP","sha256":"2d51684c0a10d450ce2ddb9cc2b0cfc769857b9a817c9447d1de51a9bc323e96","bytes":48000,"includes":["2502320000_DXF.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/c431ed1c-41f2-41a5-8de7-03a4d6b6c5fc/original/2502320000_DXF.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["2502320000_back.DXF","2502320000_bottom.DXF","2502320000_front.DXF","2502320000_left.DXF","2502320000_right.DXF","2502320000_top.DXF"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2502320000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2502320000/native-2d51684c0a10d450ce2ddb9c-zip"},{"id":"native-4e5ae822d426d3cdc1ce8e6d-zip","name":"2502320000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/402f2ae7-f11d-4a38-9614-46414077fc02/original/2502320000_DWG.zip","availability":"direct","sha256":"4e5ae822d426d3cdc1ce8e6d0bea69bdf7d46089223fbefe76fe9177098a35b0","bytes":71958,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"2502320000_DWG.zip","format":"ZIP","sha256":"4e5ae822d426d3cdc1ce8e6d0bea69bdf7d46089223fbefe76fe9177098a35b0","bytes":71958,"includes":["2502320000_DWG.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/402f2ae7-f11d-4a38-9614-46414077fc02/original/2502320000_DWG.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["2502320000_back.DWG","2502320000_bottom.DWG","2502320000_front.DWG","2502320000_left.DWG","2502320000_right.DWG","2502320000_top.DWG"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2502320000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2502320000/native-4e5ae822d426d3cdc1ce8e6d-zip"}],"artifacts":[{"id":"native-4eca6b465e8e1ef4816ed348-step","name":"2502320000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/61daaa9e-d354-4d11-9321-3dc6f8c4e61a/original/2502320000.stp","sourceSha256":"4eca6b465e8e1ef4816ed348abbcbda75e55f66814f40894f8aef22e032600b6","artifactSha256":"84d22940b1d73f5a49f1808443119030db551b4c6e35fdffce7708cdb73b7f26","bytes":124587,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2502320000/native-4eca6b465e8e1ef4816ed348-step","customerPrice":0},{"id":"native-2d51684c0a10d450ce2ddb9c-zip","name":"2502320000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DXF"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/c431ed1c-41f2-41a5-8de7-03a4d6b6c5fc/original/2502320000_DXF.zip","sourceSha256":"2d51684c0a10d450ce2ddb9cc2b0cfc769857b9a817c9447d1de51a9bc323e96","artifactSha256":"2d51684c0a10d450ce2ddb9cc2b0cfc769857b9a817c9447d1de51a9bc323e96","bytes":48000,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2502320000/native-2d51684c0a10d450ce2ddb9c-zip","customerPrice":0},{"id":"native-4e5ae822d426d3cdc1ce8e6d-zip","name":"2502320000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/402f2ae7-f11d-4a38-9614-46414077fc02/original/2502320000_DWG.zip","sourceSha256":"4e5ae822d426d3cdc1ce8e6d0bea69bdf7d46089223fbefe76fe9177098a35b0","artifactSha256":"4e5ae822d426d3cdc1ce8e6d0bea69bdf7d46089223fbefe76fe9177098a35b0","bytes":71958,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2502320000/native-4e5ae822d426d3cdc1ce8e6d-zip","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"ALO 16 BL — Feed-through terminal block / Supply terminal, PUSH IN, blue, 16 mm², 76 A, 800 V, Number of connections: 2, Number of levels: 1, TS 35, V-0, Wemid"},{"label":"Manufacturer","value":"Weidmüller"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"2502320000"},{"label":"Manufacturer reference","value":"2502320000"},{"label":"Manufacturer type","value":"ALO 16 BL"},{"label":"Available native formats","value":"DWG / DXF / STEP"},{"label":"Listed file formats","value":"DWG, DXF, STEP"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"2 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 50 files / 512 MiB daily; registered free: 1,000 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/weidmueller-article-2502320000/native-2d51684c0a10d450ce2ddb9c-zip?asset=97bf7ef2c38ec9aed6cdcf6a29a56dbc9ba423fff167ae1ee9aad2b2d975a9ad","relatedReferences":[{"name":"Terminal strip assembly","url":"https://eloragrid.ai/objects/terminal-strip"},{"name":"Cable gland","url":"https://eloragrid.ai/objects/ga-cable-gland"}],"fileChoiceGuidance":["Start with 2502320000. The files above belong to Weidmüller's ALO 16 BL — Feed-through terminal block / Supply terminal, PUSH IN, blue, 16 mm², 76 A, 800 V, Number of connections: 2, Number of levels: 1, TS 35, V-0, Wemid resource; match any model or option suffix in the filename to your selected unit.","Available here: STEP, ZIP. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"A terminal provides an identified point for joining wires to equipment or to other wires. Terminal strips organise those connections so they can be wired and checked.","example":"In a substation relay panel, numbered terminals connect the switchyard cables to the protection and control equipment.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Field wiring","Identified terminal connections","Panel equipment"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Weidmüller official source","url":"https://eshop.weidmueller.com.cn/en/alo-16-bl/p/2502320000/downloads#engineering-support"}],"profileId":"terminal"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/weidmueller-article-2502320000"}