{"id":"weidmueller-article-2530520000","name":"VPU PV I+II 3 1000 E — Combination arrester power engineering DC (Type 1+2) / Surge voltage arrester  (power supply systems) Surge protection I / II, Type I + II, I, II, DC","manufacturer":"Weidmüller","category":"power-supplies","description":"Weidmüller VPU PV I+II 3 1000 E — Combination arrester power engineering DC (Type 1+2) / Surge voltage arrester  (power supply systems) Surge protection I / II, Type I + II, I, II, DC. Manufacturer CAD files for power supplies equipment selection and layout, identified by article 2530520000.","equipment":["power supplies","VPU PV I+II 3 1000 E — Combination arrester power engineering DC (Type 1+2) / Surge voltage arrester  (power supply systems) Surge protection I / II, Type I + II, I, II, DC"],"keywords":["Weidmüller","VPU PV I+II 3 1000 E — Combination arrester power engineering DC (Type 1+2) / Surge voltage arrester  (power supply systems) Surge protection I / II, Type I + II, I, II, DC","2530520000","power supplies","DWG","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"2530520000","sourceUrl":"https://eshop.weidmueller.com.cn/en/vpu-pv-iii-3-1000-e/p/2530520000/downloads#engineering-support","officialEvidenceUrl":"https://eshop.weidmueller.com.cn/en/vpu-pv-iii-3-1000-e/p/2530520000/downloads#engineering-support","sourcePublisher":"Weidmüller","formats":["DWG","DXF","STEP"],"availability":"direct","accessNote":"Manufacturer CAD files for the listed equipment reference. Open the original files in compatible CAD software.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"2530520000","sourceUrl":"https://eshop.weidmueller.com.cn/en/vpu-pv-iii-3-1000-e/p/2530520000/downloads#engineering-support"},{"label":"Manufacturer type","value":"VPU PV I+II 3 1000 E","sourceUrl":"https://eshop.weidmueller.com.cn/en/vpu-pv-iii-3-1000-e/p/2530520000/downloads#engineering-support"},{"label":"Available native formats","value":"DWG / DXF / STEP","sourceUrl":"https://eshop.weidmueller.com.cn/en/vpu-pv-iii-3-1000-e/p/2530520000/downloads#engineering-support"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-3cc92adcba6e540173af4c7d-zip","name":"2530520000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/5efee62e-cae3-467a-a6a3-3b359b11cbc6/original/2530520000_DWG.zip","availability":"direct","sha256":"3cc92adcba6e540173af4c7d79847efc8e68a124ec9ac94f8d32f6d5a91c1513","bytes":52981,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"2530520000_DWG.zip","format":"ZIP","sha256":"3cc92adcba6e540173af4c7d79847efc8e68a124ec9ac94f8d32f6d5a91c1513","bytes":52981,"includes":["2530520000_DWG.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/5efee62e-cae3-467a-a6a3-3b359b11cbc6/original/2530520000_DWG.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["2530520000_back.DWG","2530520000_bottom.DWG","2530520000_front.DWG","2530520000_left.DWG","2530520000_right.DWG","2530520000_top.DWG"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2530520000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2530520000/native-3cc92adcba6e540173af4c7d-zip"},{"id":"native-0a62f741e00eb7b9e8fab072-zip","name":"2530520000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/6119d783-208e-4af7-80fd-b5e90b450aba/original/2530520000_DXF.zip","availability":"direct","sha256":"0a62f741e00eb7b9e8fab072d4802e507ea4cf74e90b9b6e6c792e1cc984bce0","bytes":46302,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"2530520000_DXF.zip","format":"ZIP","sha256":"0a62f741e00eb7b9e8fab072d4802e507ea4cf74e90b9b6e6c792e1cc984bce0","bytes":46302,"includes":["2530520000_DXF.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/6119d783-208e-4af7-80fd-b5e90b450aba/original/2530520000_DXF.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["2530520000_back.DXF","2530520000_bottom.DXF","2530520000_front.DXF","2530520000_left.DXF","2530520000_right.DXF","2530520000_top.DXF"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2530520000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2530520000/native-0a62f741e00eb7b9e8fab072-zip"},{"id":"native-a86c6d895f355b98f3e5dd01-step","name":"2530640000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://assets.dam.weidmueller.com/assets/api/c2741aa5-32f0-41a2-a957-84d85bc441d0/original/2530640000.stp","availability":"direct","sha256":"a86c6d895f355b98f3e5dd0135867b68f1438a78f5202697fbe877179ca89984","bytes":1374256,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"2530640000.stp.zip","format":"ZIP","sha256":"16c088914cbc2c2fea411d75599dde3c2ae5691f45af483bc8ad42c9b76da22f","bytes":223612,"includes":["2530640000.stp"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/c2741aa5-32f0-41a2-a957-84d85bc441d0/original/2530640000.stp","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2530520000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2530520000/native-a86c6d895f355b98f3e5dd01-step"}],"artifacts":[{"id":"native-3cc92adcba6e540173af4c7d-zip","name":"2530520000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/5efee62e-cae3-467a-a6a3-3b359b11cbc6/original/2530520000_DWG.zip","sourceSha256":"3cc92adcba6e540173af4c7d79847efc8e68a124ec9ac94f8d32f6d5a91c1513","artifactSha256":"3cc92adcba6e540173af4c7d79847efc8e68a124ec9ac94f8d32f6d5a91c1513","bytes":52981,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2530520000/native-3cc92adcba6e540173af4c7d-zip","customerPrice":0},{"id":"native-0a62f741e00eb7b9e8fab072-zip","name":"2530520000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DXF"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/6119d783-208e-4af7-80fd-b5e90b450aba/original/2530520000_DXF.zip","sourceSha256":"0a62f741e00eb7b9e8fab072d4802e507ea4cf74e90b9b6e6c792e1cc984bce0","artifactSha256":"0a62f741e00eb7b9e8fab072d4802e507ea4cf74e90b9b6e6c792e1cc984bce0","bytes":46302,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2530520000/native-0a62f741e00eb7b9e8fab072-zip","customerPrice":0},{"id":"native-a86c6d895f355b98f3e5dd01-step","name":"2530640000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/c2741aa5-32f0-41a2-a957-84d85bc441d0/original/2530640000.stp","sourceSha256":"a86c6d895f355b98f3e5dd0135867b68f1438a78f5202697fbe877179ca89984","artifactSha256":"16c088914cbc2c2fea411d75599dde3c2ae5691f45af483bc8ad42c9b76da22f","bytes":223612,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2530520000/native-a86c6d895f355b98f3e5dd01-step","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"VPU PV I+II 3 1000 E — Combination arrester power engineering DC (Type 1+2) / Surge voltage arrester  (power supply systems) Surge protection I / II, Type I + II, I, II, DC"},{"label":"Manufacturer","value":"Weidmüller"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"2530520000"},{"label":"Manufacturer reference","value":"2530520000"},{"label":"Manufacturer type","value":"VPU PV I+II 3 1000 E"},{"label":"Available native formats","value":"DWG / DXF / STEP"},{"label":"Listed file formats","value":"DWG, DXF, STEP"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"2 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 50 files / 512 MiB daily; registered free: 1,000 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/weidmueller-article-2530520000/native-3cc92adcba6e540173af4c7d-zip?asset=5b479228e15d92f0f754b2c1bb31618c164f0a3bfda2828d8fda8c4fa69c807b","relatedReferences":[{"name":"DIN-rail AC/DC power supply","url":"https://eloragrid.ai/objects/ga-din-rail-ac-dc-power-supply"},{"name":"AC UPS cabinet","url":"https://eloragrid.ai/objects/ga-ac-ups-cabinet"}],"fileChoiceGuidance":["Start with 2530520000. The files above belong to Weidmüller's VPU PV I+II 3 1000 E — Combination arrester power engineering DC (Type 1+2) / Surge voltage arrester  (power supply systems) Surge protection I / II, Type I + II, I, II, DC resource; match any model or option suffix in the filename to your selected unit.","Available here: ZIP, STEP. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"A surge protective device limits brief voltage spikes by providing a path for surge current under its designed conditions.","example":"At a substation cable interface, it can help limit a transient voltage reaching connected equipment.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Brief voltage spike","Surge protection responds","Voltage is limited"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Weidmüller official source","url":"https://eshop.weidmueller.com.cn/en/vpu-pv-iii-3-1000-e/p/2530520000/downloads#engineering-support"}],"profileId":"surge"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/weidmueller-article-2530520000"}