{"id":"weidmueller-article-2582530000","name":"AAP21 4 LI BL/OR — Feed-through terminal block / Feed-through terminal block, PUSH IN, 4 mm², 250 V, 32 A, Number of connections: 1","manufacturer":"Weidmüller","category":"wiring","description":"Weidmüller AAP21 4 LI BL/OR — Feed-through terminal block / Feed-through terminal block, PUSH IN, 4 mm², 250 V, 32 A, Number of connections: 1. Manufacturer CAD files for wiring equipment selection and layout, identified by article 2582530000.","equipment":["wiring","AAP21 4 LI BL/OR — Feed-through terminal block / Feed-through terminal block, PUSH IN, 4 mm², 250 V, 32 A, Number of connections: 1"],"keywords":["Weidmüller","AAP21 4 LI BL/OR — Feed-through terminal block / Feed-through terminal block, PUSH IN, 4 mm², 250 V, 32 A, Number of connections: 1","2582530000","wiring","DWG","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"2582530000","sourceUrl":"https://eshop.weidmueller.com.cn/en/aap21-4-li-blor/p/2582530000/downloads#engineering-support","officialEvidenceUrl":"https://eshop.weidmueller.com.cn/en/aap21-4-li-blor/p/2582530000/downloads#engineering-support","sourcePublisher":"Weidmüller","formats":["DWG","DXF","STEP"],"availability":"direct","accessNote":"Manufacturer CAD files for the listed equipment reference. Open the original files in compatible CAD software.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"2582530000","sourceUrl":"https://eshop.weidmueller.com.cn/en/aap21-4-li-blor/p/2582530000/downloads#engineering-support"},{"label":"Manufacturer type","value":"AAP21 4 LI BL/OR","sourceUrl":"https://eshop.weidmueller.com.cn/en/aap21-4-li-blor/p/2582530000/downloads#engineering-support"},{"label":"Available native formats","value":"DWG / DXF / STEP","sourceUrl":"https://eshop.weidmueller.com.cn/en/aap21-4-li-blor/p/2582530000/downloads#engineering-support"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-bb2296be63fb66dfcbff5d92-zip","name":"2582530000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/75852ee0-c590-40db-9350-a6a026a804dc/original/2582530000_DWG.zip","availability":"direct","sha256":"bb2296be63fb66dfcbff5d92b9bb6336ef05252ca6dc884edb4f7fcb0bf9056c","bytes":59787,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"2582530000_DWG.zip","format":"ZIP","sha256":"bb2296be63fb66dfcbff5d92b9bb6336ef05252ca6dc884edb4f7fcb0bf9056c","bytes":59787,"includes":["2582530000_DWG.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/75852ee0-c590-40db-9350-a6a026a804dc/original/2582530000_DWG.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["2582530000_back.DWG","2582530000_bottom.DWG","2582530000_front.DWG","2582530000_left.DWG","2582530000_right.DWG","2582530000_top.DWG"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2582530000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2582530000/native-bb2296be63fb66dfcbff5d92-zip"},{"id":"native-eb1ac6b49c9c8a4651985cc4-zip","name":"2582530000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/b71308ce-d8a4-45c5-be66-1356937d1391/original/2582530000_DXF.zip","availability":"direct","sha256":"eb1ac6b49c9c8a4651985cc489fda252e893cf200e55f8725a083700a97db295","bytes":49186,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"2582530000_DXF.zip","format":"ZIP","sha256":"eb1ac6b49c9c8a4651985cc489fda252e893cf200e55f8725a083700a97db295","bytes":49186,"includes":["2582530000_DXF.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/b71308ce-d8a4-45c5-be66-1356937d1391/original/2582530000_DXF.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["2582530000_back.DXF","2582530000_bottom.DXF","2582530000_front.DXF","2582530000_left.DXF","2582530000_right.DXF","2582530000_top.DXF"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2582530000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2582530000/native-eb1ac6b49c9c8a4651985cc4-zip"},{"id":"native-d711d407e6641b3f69d356b1-step","name":"2582530000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://assets.dam.weidmueller.com/assets/api/d08cc21a-f62e-4704-ad95-62118a79cef0/original/2582530000.stp","availability":"direct","sha256":"d711d407e6641b3f69d356b1f389e2758f04f1886baae44a6e36e5792f05f58b","bytes":1296713,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"2582530000.stp.zip","format":"ZIP","sha256":"640d06a7596bbf9f179efbab6b45bfa5164616eb120d63837a456c99d2f340b5","bytes":235997,"includes":["2582530000.stp"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/d08cc21a-f62e-4704-ad95-62118a79cef0/original/2582530000.stp","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2582530000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2582530000/native-d711d407e6641b3f69d356b1-step"}],"artifacts":[{"id":"native-bb2296be63fb66dfcbff5d92-zip","name":"2582530000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/75852ee0-c590-40db-9350-a6a026a804dc/original/2582530000_DWG.zip","sourceSha256":"bb2296be63fb66dfcbff5d92b9bb6336ef05252ca6dc884edb4f7fcb0bf9056c","artifactSha256":"bb2296be63fb66dfcbff5d92b9bb6336ef05252ca6dc884edb4f7fcb0bf9056c","bytes":59787,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2582530000/native-bb2296be63fb66dfcbff5d92-zip","customerPrice":0},{"id":"native-eb1ac6b49c9c8a4651985cc4-zip","name":"2582530000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DXF"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/b71308ce-d8a4-45c5-be66-1356937d1391/original/2582530000_DXF.zip","sourceSha256":"eb1ac6b49c9c8a4651985cc489fda252e893cf200e55f8725a083700a97db295","artifactSha256":"eb1ac6b49c9c8a4651985cc489fda252e893cf200e55f8725a083700a97db295","bytes":49186,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2582530000/native-eb1ac6b49c9c8a4651985cc4-zip","customerPrice":0},{"id":"native-d711d407e6641b3f69d356b1-step","name":"2582530000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/d08cc21a-f62e-4704-ad95-62118a79cef0/original/2582530000.stp","sourceSha256":"d711d407e6641b3f69d356b1f389e2758f04f1886baae44a6e36e5792f05f58b","artifactSha256":"640d06a7596bbf9f179efbab6b45bfa5164616eb120d63837a456c99d2f340b5","bytes":235997,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2582530000/native-d711d407e6641b3f69d356b1-step","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"AAP21 4 LI BL/OR — Feed-through terminal block / Feed-through terminal block, PUSH IN, 4 mm², 250 V, 32 A, Number of connections: 1"},{"label":"Manufacturer","value":"Weidmüller"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"2582530000"},{"label":"Manufacturer reference","value":"2582530000"},{"label":"Manufacturer type","value":"AAP21 4 LI BL/OR"},{"label":"Available native formats","value":"DWG / DXF / STEP"},{"label":"Listed file formats","value":"DWG, DXF, STEP"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"2 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 3 files / 25 MiB daily; registered free: 100 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/weidmueller-article-2582530000/native-bb2296be63fb66dfcbff5d92-zip?asset=7c35d24e5e76010af1435d785ce569c1d1bf48b77967f48311f4e9625f49ea4e","relatedReferences":[{"name":"Terminal strip assembly","url":"https://eloragrid.ai/objects/terminal-strip"},{"name":"Cable gland","url":"https://eloragrid.ai/objects/ga-cable-gland"}],"fileChoiceGuidance":["Start with 2582530000. The files above belong to Weidmüller's AAP21 4 LI BL/OR — Feed-through terminal block / Feed-through terminal block, PUSH IN, 4 mm², 250 V, 32 A, Number of connections: 1 resource; match any model or option suffix in the filename to your selected unit.","Available here: ZIP, STEP. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"A terminal provides an identified point for joining wires to equipment or to other wires. Terminal strips organise those connections so they can be wired and checked.","example":"In a substation relay panel, numbered terminals connect the switchyard cables to the protection and control equipment.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Field wiring","Identified terminal connections","Panel equipment"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Weidmüller official source","url":"https://eshop.weidmueller.com.cn/en/aap21-4-li-blor/p/2582530000/downloads#engineering-support"}],"profileId":"terminal"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/weidmueller-article-2582530000"}