{"id":"weidmueller-article-2591180000","name":"VPU AC II 1 N-PE 305/65 — Surge arrester power engineering AC (type 2) / Surge voltage arrester  (power supply systems) Surge protection, Type II, Type III, Low voltage network: TT nur für N-PE, AC, 230 V","manufacturer":"Weidmüller","category":"power-supplies","description":"Weidmüller VPU AC II 1 N-PE 305/65 — Surge arrester power engineering AC (type 2) / Surge voltage arrester  (power supply systems) Surge protection, Type II, Type III, Low voltage network: TT nur für N-PE, AC, 230 V. Manufacturer CAD files for power supplies equipment selection and layout, identified by article 2591180000.","equipment":["power supplies","VPU AC II 1 N-PE 305/65 — Surge arrester power engineering AC (type 2) / Surge voltage arrester  (power supply systems) Surge protection, Type II, Type III, Low voltage network: TT nur für N-PE, AC, 230 V"],"keywords":["Weidmüller","VPU AC II 1 N-PE 305/65 — Surge arrester power engineering AC (type 2) / Surge voltage arrester  (power supply systems) Surge protection, Type II, Type III, Low voltage network: TT nur für N-PE, AC, 230 V","2591180000","power supplies","DWG","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"2591180000","sourceUrl":"https://eshop.weidmueller.com.cn/en/vpu-ac-ii-1-n-pe-30565/p/2591180000/downloads#engineering-support","officialEvidenceUrl":"https://eshop.weidmueller.com.cn/en/vpu-ac-ii-1-n-pe-30565/p/2591180000/downloads#engineering-support","sourcePublisher":"Weidmüller","formats":["DWG","DXF","STEP"],"availability":"direct","accessNote":"Manufacturer CAD files for the listed equipment reference. Open the original files in compatible CAD software.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"2591180000","sourceUrl":"https://eshop.weidmueller.com.cn/en/vpu-ac-ii-1-n-pe-30565/p/2591180000/downloads#engineering-support"},{"label":"Manufacturer type","value":"VPU AC II 1 N-PE 305/65","sourceUrl":"https://eshop.weidmueller.com.cn/en/vpu-ac-ii-1-n-pe-30565/p/2591180000/downloads#engineering-support"},{"label":"Available native formats","value":"DWG / DXF / STEP","sourceUrl":"https://eshop.weidmueller.com.cn/en/vpu-ac-ii-1-n-pe-30565/p/2591180000/downloads#engineering-support"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-038ed28c99d3bfd6387958bb-step","name":"2591180000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://assets.dam.weidmueller.com/assets/api/b5027ee0-29d4-4712-9fbc-b35072a8a059/original/2591180000.stp","availability":"direct","sha256":"038ed28c99d3bfd6387958bb73f6dbca614da36cec8b0d746f3cd4f08afa9b2b","bytes":593642,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"2591180000.stp.zip","format":"ZIP","sha256":"e786e943e67b0ba3182e4b0c3d3e5a1b418d7838e38ceccbc737651c5ae35fe3","bytes":105996,"includes":["2591180000.stp"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/b5027ee0-29d4-4712-9fbc-b35072a8a059/original/2591180000.stp","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2591180000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2591180000/native-038ed28c99d3bfd6387958bb-step"},{"id":"native-f5fa9ec5a8db8682d6c33d74-zip","name":"2591180000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/a48ffc03-e481-4d13-85a9-23ac6dd726d0/original/2591180000_DXF.zip","availability":"direct","sha256":"f5fa9ec5a8db8682d6c33d741def8db9f1c9a4da578f5fb4ecf921d4ad835a04","bytes":36151,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"2591180000_DXF.zip","format":"ZIP","sha256":"f5fa9ec5a8db8682d6c33d741def8db9f1c9a4da578f5fb4ecf921d4ad835a04","bytes":36151,"includes":["2591180000_DXF.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/a48ffc03-e481-4d13-85a9-23ac6dd726d0/original/2591180000_DXF.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["2591180000_back.DXF","2591180000_bottom.DXF","2591180000_front.DXF","2591180000_left.DXF","2591180000_right.DXF","2591180000_top.DXF"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2591180000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2591180000/native-f5fa9ec5a8db8682d6c33d74-zip"},{"id":"native-e2b3d26dd61351f4e21372bc-zip","name":"2591180000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/d8ca5f6e-b9b0-4305-9284-b205e9abb7dc/original/2591180000_DWG.zip","availability":"direct","sha256":"e2b3d26dd61351f4e21372bcf37740c1212ad0008b9bd2e450884b9ae7e6bab0","bytes":58552,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"2591180000_DWG.zip","format":"ZIP","sha256":"e2b3d26dd61351f4e21372bcf37740c1212ad0008b9bd2e450884b9ae7e6bab0","bytes":58552,"includes":["2591180000_DWG.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/d8ca5f6e-b9b0-4305-9284-b205e9abb7dc/original/2591180000_DWG.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["2591180000_back.DWG","2591180000_bottom.DWG","2591180000_front.DWG","2591180000_left.DWG","2591180000_right.DWG","2591180000_top.DWG"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2591180000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2591180000/native-e2b3d26dd61351f4e21372bc-zip"}],"artifacts":[{"id":"native-038ed28c99d3bfd6387958bb-step","name":"2591180000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/b5027ee0-29d4-4712-9fbc-b35072a8a059/original/2591180000.stp","sourceSha256":"038ed28c99d3bfd6387958bb73f6dbca614da36cec8b0d746f3cd4f08afa9b2b","artifactSha256":"e786e943e67b0ba3182e4b0c3d3e5a1b418d7838e38ceccbc737651c5ae35fe3","bytes":105996,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2591180000/native-038ed28c99d3bfd6387958bb-step","customerPrice":0},{"id":"native-f5fa9ec5a8db8682d6c33d74-zip","name":"2591180000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DXF"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/a48ffc03-e481-4d13-85a9-23ac6dd726d0/original/2591180000_DXF.zip","sourceSha256":"f5fa9ec5a8db8682d6c33d741def8db9f1c9a4da578f5fb4ecf921d4ad835a04","artifactSha256":"f5fa9ec5a8db8682d6c33d741def8db9f1c9a4da578f5fb4ecf921d4ad835a04","bytes":36151,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2591180000/native-f5fa9ec5a8db8682d6c33d74-zip","customerPrice":0},{"id":"native-e2b3d26dd61351f4e21372bc-zip","name":"2591180000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/d8ca5f6e-b9b0-4305-9284-b205e9abb7dc/original/2591180000_DWG.zip","sourceSha256":"e2b3d26dd61351f4e21372bcf37740c1212ad0008b9bd2e450884b9ae7e6bab0","artifactSha256":"e2b3d26dd61351f4e21372bcf37740c1212ad0008b9bd2e450884b9ae7e6bab0","bytes":58552,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2591180000/native-e2b3d26dd61351f4e21372bc-zip","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"VPU AC II 1 N-PE 305/65 — Surge arrester power engineering AC (type 2) / Surge voltage arrester  (power supply systems) Surge protection, Type II, Type III, Low voltage network: TT nur für N-PE, AC, 230 V"},{"label":"Manufacturer","value":"Weidmüller"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"2591180000"},{"label":"Manufacturer reference","value":"2591180000"},{"label":"Manufacturer type","value":"VPU AC II 1 N-PE 305/65"},{"label":"Available native formats","value":"DWG / DXF / STEP"},{"label":"Listed file formats","value":"DWG, DXF, STEP"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"2 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 50 files / 512 MiB daily; registered free: up to 60 individual files/formats per 24 hours from first admission, subject to 1 GiB/UTC day and shared 10 GiB/day or lower delivery safeguards; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/weidmueller-article-2591180000/native-f5fa9ec5a8db8682d6c33d74-zip?asset=d214696c70c8bd03211d80864fca341f477695eb5db2c4b5ad7b974f23026689","relatedReferences":[{"name":"DIN-rail AC/DC power supply","url":"https://eloragrid.ai/objects/ga-din-rail-ac-dc-power-supply"},{"name":"AC UPS cabinet","url":"https://eloragrid.ai/objects/ga-ac-ups-cabinet"}],"fileChoiceGuidance":["Start with 2591180000. The files above belong to Weidmüller's VPU AC II 1 N-PE 305/65 — Surge arrester power engineering AC (type 2) / Surge voltage arrester  (power supply systems) Surge protection, Type II, Type III, Low voltage network: TT nur für N-PE, AC, 230 V resource; match any model or option suffix in the filename to your selected unit.","Available here: STEP, ZIP. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"A surge protective device limits brief voltage spikes by providing a path for surge current under its designed conditions.","example":"At a substation cable interface, it can help limit a transient voltage reaching connected equipment.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Brief voltage spike","Surge protection responds","Voltage is limited"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Weidmüller official source","url":"https://eshop.weidmueller.com.cn/en/vpu-ac-ii-1-n-pe-30565/p/2591180000/downloads#engineering-support"}],"profileId":"surge"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/weidmueller-article-2591180000"}