{"id":"weidmueller-article-2638070000","name":"VPU AC I 3+1 R 275/25 LCF MB — Lightning current arrester power engineering AC (type 1) / Surge voltage arrester  (power supply systems) Surge protection, Leakage-current-free, with remote contact, Type I + II, Low voltage network: TN-C-S, TN-S, TT, IT with N, IT without N, I, II, III, IV, 3-phase 230/400 V, 230 V","manufacturer":"Weidmüller","category":"power-supplies","description":"Weidmüller VPU AC I 3+1 R 275/25 LCF MB — Lightning current arrester power engineering AC (type 1) / Surge voltage arrester  (power supply systems) Surge protection, Leakage-current-free, with remote contact, Type I + II, Low voltage network: TN-C-S, TN-S, TT, IT with N, IT without N, I, II, III, IV, 3-phase 230/400 V, 230 V. Manufacturer CAD files for power supplies equipment selection and layout, identified by article 2638070000.","equipment":["power supplies","VPU AC I 3+1 R 275/25 LCF MB — Lightning current arrester power engineering AC (type 1) / Surge voltage arrester  (power supply systems) Surge protection, Leakage-current-free, with remote contact, Type I + II, Low voltage network: TN-C-S, TN-S, TT, IT with N, IT without N, I, II, III, IV, 3-phase 230/400 V, 230 V"],"keywords":["Weidmüller","VPU AC I 3+1 R 275/25 LCF MB — Lightning current arrester power engineering AC (type 1) / Surge voltage arrester  (power supply systems) Surge protection, Leakage-current-free, with remote contact, Type I + II, Low voltage network: TN-C-S, TN-S, TT, IT with N, IT without N, I, II, III, IV, 3-phase 230/400 V, 230 V","2638070000","power supplies","DWG","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"2638070000","sourceUrl":"https://eshop.weidmueller.com.cn/en/vpu-ac-i-31-r-27525-lcf-mb/p/2638070000/downloads#engineering-support","officialEvidenceUrl":"https://eshop.weidmueller.com.cn/en/vpu-ac-i-31-r-27525-lcf-mb/p/2638070000/downloads#engineering-support","sourcePublisher":"Weidmüller","formats":["DWG","DXF","STEP"],"availability":"direct","accessNote":"Manufacturer CAD files for the listed equipment reference. Open the original files in compatible CAD software.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"2638070000","sourceUrl":"https://eshop.weidmueller.com.cn/en/vpu-ac-i-31-r-27525-lcf-mb/p/2638070000/downloads#engineering-support"},{"label":"Manufacturer type","value":"VPU AC I 3+1 R 275/25 LCF MB","sourceUrl":"https://eshop.weidmueller.com.cn/en/vpu-ac-i-31-r-27525-lcf-mb/p/2638070000/downloads#engineering-support"},{"label":"Available native formats","value":"DWG / DXF / STEP","sourceUrl":"https://eshop.weidmueller.com.cn/en/vpu-ac-i-31-r-27525-lcf-mb/p/2638070000/downloads#engineering-support"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-41d0f58f5651bab01ed1cf53-zip","name":"2638070000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/b510b1f7-e882-4d8c-9462-9e900b434883/original/2638070000_DWG.zip","availability":"direct","sha256":"41d0f58f5651bab01ed1cf537a306115b71db617387c6fc13f38efd0e7eaaae9","bytes":56173,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"2638070000_DWG.zip","format":"ZIP","sha256":"41d0f58f5651bab01ed1cf537a306115b71db617387c6fc13f38efd0e7eaaae9","bytes":56173,"includes":["2638070000_DWG.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/b510b1f7-e882-4d8c-9462-9e900b434883/original/2638070000_DWG.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["2638070000_back.DWG","2638070000_bottom.DWG","2638070000_front.DWG","2638070000_left.DWG","2638070000_right.DWG","2638070000_top.DWG"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2638070000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2638070000/native-41d0f58f5651bab01ed1cf53-zip"},{"id":"native-5196117716e5f49da4491987-step","name":"2638070000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://assets.dam.weidmueller.com/assets/api/b1ee4ac9-86fc-46a6-aaa7-6d918b90303f/original/2638070000.stp","availability":"direct","sha256":"5196117716e5f49da4491987608542aa9b533955f5eed8633bcb075e58e9e3c2","bytes":1007255,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"2638070000.stp.zip","format":"ZIP","sha256":"702949c7002a81bda0d6b44b01087c6010e7489b24d960e9daa092a3a3d9aeea","bytes":162386,"includes":["2638070000.stp"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/b1ee4ac9-86fc-46a6-aaa7-6d918b90303f/original/2638070000.stp","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2638070000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2638070000/native-5196117716e5f49da4491987-step"},{"id":"native-6f1f6372b357f1a16dd9b231-zip","name":"2638070000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/9ac17a84-2824-43e0-97b8-53152811a9d0/original/2638070000_DXF.zip","availability":"direct","sha256":"6f1f6372b357f1a16dd9b231482ebadae4cdebe9170aaa9e609a242e36ce3947","bytes":50207,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"2638070000_DXF.zip","format":"ZIP","sha256":"6f1f6372b357f1a16dd9b231482ebadae4cdebe9170aaa9e609a242e36ce3947","bytes":50207,"includes":["2638070000_DXF.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/9ac17a84-2824-43e0-97b8-53152811a9d0/original/2638070000_DXF.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["2638070000_back.DXF","2638070000_bottom.DXF","2638070000_front.DXF","2638070000_left.DXF","2638070000_right.DXF","2638070000_top.DXF"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2638070000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2638070000/native-6f1f6372b357f1a16dd9b231-zip"}],"artifacts":[{"id":"native-41d0f58f5651bab01ed1cf53-zip","name":"2638070000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/b510b1f7-e882-4d8c-9462-9e900b434883/original/2638070000_DWG.zip","sourceSha256":"41d0f58f5651bab01ed1cf537a306115b71db617387c6fc13f38efd0e7eaaae9","artifactSha256":"41d0f58f5651bab01ed1cf537a306115b71db617387c6fc13f38efd0e7eaaae9","bytes":56173,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2638070000/native-41d0f58f5651bab01ed1cf53-zip","customerPrice":0},{"id":"native-5196117716e5f49da4491987-step","name":"2638070000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/b1ee4ac9-86fc-46a6-aaa7-6d918b90303f/original/2638070000.stp","sourceSha256":"5196117716e5f49da4491987608542aa9b533955f5eed8633bcb075e58e9e3c2","artifactSha256":"702949c7002a81bda0d6b44b01087c6010e7489b24d960e9daa092a3a3d9aeea","bytes":162386,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2638070000/native-5196117716e5f49da4491987-step","customerPrice":0},{"id":"native-6f1f6372b357f1a16dd9b231-zip","name":"2638070000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DXF"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/9ac17a84-2824-43e0-97b8-53152811a9d0/original/2638070000_DXF.zip","sourceSha256":"6f1f6372b357f1a16dd9b231482ebadae4cdebe9170aaa9e609a242e36ce3947","artifactSha256":"6f1f6372b357f1a16dd9b231482ebadae4cdebe9170aaa9e609a242e36ce3947","bytes":50207,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2638070000/native-6f1f6372b357f1a16dd9b231-zip","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"VPU AC I 3+1 R 275/25 LCF MB — Lightning current arrester power engineering AC (type 1) / Surge voltage arrester  (power supply systems) Surge protection, Leakage-current-free, with remote contact, Type I + II, Low voltage network: TN-C-S, TN-S, TT, IT with N, IT without N, I, II, III, IV, 3-phase 230/400 V, 230 V"},{"label":"Manufacturer","value":"Weidmüller"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"2638070000"},{"label":"Manufacturer reference","value":"2638070000"},{"label":"Manufacturer type","value":"VPU AC I 3+1 R 275/25 LCF MB"},{"label":"Available native formats","value":"DWG / DXF / STEP"},{"label":"Listed file formats","value":"DWG, DXF, STEP"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"2 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 50 files / 512 MiB daily; registered free: 1,000 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/weidmueller-article-2638070000/native-41d0f58f5651bab01ed1cf53-zip?asset=b0bbdb740ba1bce247490d6be889ec06088b77ee01bf04211e34a7f361420ebe","relatedReferences":[{"name":"DIN-rail AC/DC power supply","url":"https://eloragrid.ai/objects/ga-din-rail-ac-dc-power-supply"},{"name":"AC UPS cabinet","url":"https://eloragrid.ai/objects/ga-ac-ups-cabinet"}],"fileChoiceGuidance":["Start with 2638070000. The files above belong to Weidmüller's VPU AC I 3+1 R 275/25 LCF MB — Lightning current arrester power engineering AC (type 1) / Surge voltage arrester  (power supply systems) Surge protection, Leakage-current-free, with remote contact, Type I + II, Low voltage network: TN-C-S, TN-S, TT, IT with N, IT without N, I, II, III, IV, 3-phase 230/400 V, 230 V resource; match any model or option suffix in the filename to your selected unit.","Available here: ZIP, STEP. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"A surge protective device limits brief voltage spikes by providing a path for surge current under its designed conditions.","example":"At a substation cable interface, it can help limit a transient voltage reaching connected equipment.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Brief voltage spike","Surge protection responds","Voltage is limited"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Weidmüller official source","url":"https://eshop.weidmueller.com.cn/en/vpu-ac-i-31-r-27525-lcf-mb/p/2638070000/downloads#engineering-support"}],"profileId":"surge"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/weidmueller-article-2638070000"}