{"id":"weidmueller-article-2656670000","name":"TGD ELM-4 CL2 — Electronic load monitoring / Electronic load monitoring, Electronic fuse, 4 A, 24 V DC","manufacturer":"Weidmüller","category":"switchgear","description":"Weidmüller TGD ELM-4 CL2 — Electronic load monitoring / Electronic load monitoring, Electronic fuse, 4 A, 24 V DC. Manufacturer CAD files for switchgear equipment selection and layout, identified by article 2656670000.","equipment":["switchgear","TGD ELM-4 CL2 — Electronic load monitoring / Electronic load monitoring, Electronic fuse, 4 A, 24 V DC"],"keywords":["Weidmüller","TGD ELM-4 CL2 — Electronic load monitoring / Electronic load monitoring, Electronic fuse, 4 A, 24 V DC","2656670000","switchgear","DWG","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"2656670000","sourceUrl":"https://eshop.weidmueller.com.cn/en/tgd-elm-4-cl2/p/2656670000/downloads#engineering-support","officialEvidenceUrl":"https://eshop.weidmueller.com.cn/en/tgd-elm-4-cl2/p/2656670000/downloads#engineering-support","sourcePublisher":"Weidmüller","formats":["DWG","DXF","STEP"],"availability":"direct","accessNote":"Manufacturer CAD files for the listed equipment reference. Open the original files in compatible CAD software.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"2656670000","sourceUrl":"https://eshop.weidmueller.com.cn/en/tgd-elm-4-cl2/p/2656670000/downloads#engineering-support"},{"label":"Manufacturer type","value":"TGD ELM-4 CL2","sourceUrl":"https://eshop.weidmueller.com.cn/en/tgd-elm-4-cl2/p/2656670000/downloads#engineering-support"},{"label":"Available native formats","value":"DWG / DXF / STEP","sourceUrl":"https://eshop.weidmueller.com.cn/en/tgd-elm-4-cl2/p/2656670000/downloads#engineering-support"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-448dac8dd7acdd3eee09c617-step","name":"2624980000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://assets.dam.weidmueller.com/assets/api/9823c58a-1efe-4c8c-818c-c9aa97efbe37/original/2624980000.stp","availability":"direct","sha256":"448dac8dd7acdd3eee09c6171956abfdc39e29c5504d0a9df87ade3552e563c9","bytes":2075896,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"2624980000.stp.zip","format":"ZIP","sha256":"75d0b0e8234533a44c188185ff2f652791a811b06e27b03e2b5993efa66119c7","bytes":342924,"includes":["2624980000.stp"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/9823c58a-1efe-4c8c-818c-c9aa97efbe37/original/2624980000.stp","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2656670000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2656670000/native-448dac8dd7acdd3eee09c617-step"},{"id":"native-27b1609e44e935fef6add334-zip","name":"2656670000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/aa87d793-fe53-4ba9-bb5f-740f8b94c651/original/2656670000_DWG.zip","availability":"direct","sha256":"27b1609e44e935fef6add334ee0c58bc457003d56c42b4443427a9afbf46e21d","bytes":145354,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"2656670000_DWG.zip","format":"ZIP","sha256":"27b1609e44e935fef6add334ee0c58bc457003d56c42b4443427a9afbf46e21d","bytes":145354,"includes":["2656670000_DWG.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/aa87d793-fe53-4ba9-bb5f-740f8b94c651/original/2656670000_DWG.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["2656670000_back.DWG","2656670000_bottom.DWG","2656670000_front.DWG","2656670000_left.DWG","2656670000_right.DWG","2656670000_top.DWG"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2656670000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2656670000/native-27b1609e44e935fef6add334-zip"},{"id":"native-2c61fcfa436617a63ce3d0af-zip","name":"2656670000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/cf799353-01cf-41fd-a8b4-261ae271be4e/original/2656670000_DXF.zip","availability":"direct","sha256":"2c61fcfa436617a63ce3d0afe3487bed12f6b5bc74d6cfeee46104740bcfe5be","bytes":117579,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"2656670000_DXF.zip","format":"ZIP","sha256":"2c61fcfa436617a63ce3d0afe3487bed12f6b5bc74d6cfeee46104740bcfe5be","bytes":117579,"includes":["2656670000_DXF.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/cf799353-01cf-41fd-a8b4-261ae271be4e/original/2656670000_DXF.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["2656670000_back.DXF","2656670000_bottom.DXF","2656670000_front.DXF","2656670000_left.DXF","2656670000_right.DXF","2656670000_top.DXF"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2656670000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2656670000/native-2c61fcfa436617a63ce3d0af-zip"}],"artifacts":[{"id":"native-448dac8dd7acdd3eee09c617-step","name":"2624980000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/9823c58a-1efe-4c8c-818c-c9aa97efbe37/original/2624980000.stp","sourceSha256":"448dac8dd7acdd3eee09c6171956abfdc39e29c5504d0a9df87ade3552e563c9","artifactSha256":"75d0b0e8234533a44c188185ff2f652791a811b06e27b03e2b5993efa66119c7","bytes":342924,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2656670000/native-448dac8dd7acdd3eee09c617-step","customerPrice":0},{"id":"native-27b1609e44e935fef6add334-zip","name":"2656670000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/aa87d793-fe53-4ba9-bb5f-740f8b94c651/original/2656670000_DWG.zip","sourceSha256":"27b1609e44e935fef6add334ee0c58bc457003d56c42b4443427a9afbf46e21d","artifactSha256":"27b1609e44e935fef6add334ee0c58bc457003d56c42b4443427a9afbf46e21d","bytes":145354,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2656670000/native-27b1609e44e935fef6add334-zip","customerPrice":0},{"id":"native-2c61fcfa436617a63ce3d0af-zip","name":"2656670000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DXF"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/cf799353-01cf-41fd-a8b4-261ae271be4e/original/2656670000_DXF.zip","sourceSha256":"2c61fcfa436617a63ce3d0afe3487bed12f6b5bc74d6cfeee46104740bcfe5be","artifactSha256":"2c61fcfa436617a63ce3d0afe3487bed12f6b5bc74d6cfeee46104740bcfe5be","bytes":117579,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2656670000/native-2c61fcfa436617a63ce3d0af-zip","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"TGD ELM-4 CL2 — Electronic load monitoring / Electronic load monitoring, Electronic fuse, 4 A, 24 V DC"},{"label":"Manufacturer","value":"Weidmüller"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"2656670000"},{"label":"Manufacturer reference","value":"2656670000"},{"label":"Manufacturer type","value":"TGD ELM-4 CL2"},{"label":"Available native formats","value":"DWG / DXF / STEP"},{"label":"Listed file formats","value":"DWG, DXF, STEP"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"2 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 50 files / 512 MiB daily; registered free: 1,000 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/weidmueller-article-2656670000/native-27b1609e44e935fef6add334-zip?asset=cc5285be3840d9347fb5836a6cd8819ba09aeb1c07d8991ed6785f3d3a09dd54","relatedReferences":[{"name":"Switchgear panel","url":"https://eloragrid.ai/objects/switchgear-panel"},{"name":"Switchboard","url":"https://eloragrid.ai/objects/switchboard"},{"name":"Ring main unit","url":"https://eloragrid.ai/objects/ring-main-unit"}],"fileChoiceGuidance":["Start with 2656670000. The files above belong to Weidmüller's TGD ELM-4 CL2 — Electronic load monitoring / Electronic load monitoring, Electronic fuse, 4 A, 24 V DC resource; match any model or option suffix in the filename to your selected unit.","Available here: STEP, ZIP. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"A fuse contains a small element that melts and breaks the circuit when excessive current meets its operating characteristic.","example":"In a substation control panel, a fuse can protect a branch supplying an auxiliary device.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Current passes through fuse","Element responds to excessive current","Circuit opens"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Weidmüller official source","url":"https://eshop.weidmueller.com.cn/en/tgd-elm-4-cl2/p/2656670000/downloads#engineering-support"}],"profileId":"fuse"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/weidmueller-article-2656670000"}