{"id":"weidmueller-article-2736830000","name":"A2T 2.5 3C N-FT — Feed-through terminal block / Multi-tier modular terminal, 2.5 mm², 800 V, 22 A, Number of levels: 2, dark beige, orange","manufacturer":"Weidmüller","category":"wiring","description":"Weidmüller A2T 2.5 3C N-FT — Feed-through terminal block / Multi-tier modular terminal, 2.5 mm², 800 V, 22 A, Number of levels: 2, dark beige, orange. Manufacturer CAD files for wiring equipment selection and layout, identified by article 2736830000.","equipment":["wiring","A2T 2.5 3C N-FT — Feed-through terminal block / Multi-tier modular terminal, 2.5 mm², 800 V, 22 A, Number of levels: 2, dark beige, orange"],"keywords":["Weidmüller","A2T 2.5 3C N-FT — Feed-through terminal block / Multi-tier modular terminal, 2.5 mm², 800 V, 22 A, Number of levels: 2, dark beige, orange","2736830000","wiring","DWG","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"2736830000","sourceUrl":"https://eshop.weidmueller.com.cn/en/a2t-2-5-3c-n-ft/p/2736830000/downloads#engineering-support","officialEvidenceUrl":"https://eshop.weidmueller.com.cn/en/a2t-2-5-3c-n-ft/p/2736830000/downloads#engineering-support","sourcePublisher":"Weidmüller","formats":["DWG","DXF","STEP"],"availability":"direct","accessNote":"Manufacturer CAD files for the listed equipment reference. Open the original files in compatible CAD software.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"2736830000","sourceUrl":"https://eshop.weidmueller.com.cn/en/a2t-2-5-3c-n-ft/p/2736830000/downloads#engineering-support"},{"label":"Manufacturer type","value":"A2T 2.5 3C N-FT","sourceUrl":"https://eshop.weidmueller.com.cn/en/a2t-2-5-3c-n-ft/p/2736830000/downloads#engineering-support"},{"label":"Available native formats","value":"DWG / DXF / STEP","sourceUrl":"https://eshop.weidmueller.com.cn/en/a2t-2-5-3c-n-ft/p/2736830000/downloads#engineering-support"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-d9ef01e90cb6fcf38ec05183-step","name":"2736830000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://assets.dam.weidmueller.com/assets/api/da885061-09bb-4907-8542-e1dacc55063a/original/2736830000.stp","availability":"direct","sha256":"d9ef01e90cb6fcf38ec0518371d5551124426b09675888e378d4c0bd0cad9481","bytes":1393667,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"2736830000.stp.zip","format":"ZIP","sha256":"152fbb1e255ed409aeb0efefcede1f44a9600756ffeceeccacd821b8de46f42d","bytes":237274,"includes":["2736830000.stp"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/da885061-09bb-4907-8542-e1dacc55063a/original/2736830000.stp","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2736830000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2736830000/native-d9ef01e90cb6fcf38ec05183-step"},{"id":"native-32677962c94b96cef326d99e-zip","name":"2736830000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/0424e9d6-edea-4f70-9ca7-aecc84e5b618/original/2736830000_DXF.zip","availability":"direct","sha256":"32677962c94b96cef326d99e52458dc97383e735d40ac85fee09d4b876a53ece","bytes":76903,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"2736830000_DXF.zip","format":"ZIP","sha256":"32677962c94b96cef326d99e52458dc97383e735d40ac85fee09d4b876a53ece","bytes":76903,"includes":["2736830000_DXF.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/0424e9d6-edea-4f70-9ca7-aecc84e5b618/original/2736830000_DXF.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["2736830000_back.DXF","2736830000_bottom.DXF","2736830000_front.DXF","2736830000_left.DXF","2736830000_right.DXF","2736830000_top.DXF"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2736830000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2736830000/native-32677962c94b96cef326d99e-zip"},{"id":"native-3606715f4c766d65033dbb8c-zip","name":"2736830000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/62480735-aa97-4be3-a6c9-03d5fa98b1c7/original/2736830000_DWG.zip","availability":"direct","sha256":"3606715f4c766d65033dbb8cc5b1383dc2102b86e927421382604d3468469176","bytes":86059,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"2736830000_DWG.zip","format":"ZIP","sha256":"3606715f4c766d65033dbb8cc5b1383dc2102b86e927421382604d3468469176","bytes":86059,"includes":["2736830000_DWG.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/62480735-aa97-4be3-a6c9-03d5fa98b1c7/original/2736830000_DWG.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["2736830000_back.DWG","2736830000_bottom.DWG","2736830000_front.DWG","2736830000_left.DWG","2736830000_right.DWG","2736830000_top.DWG"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2736830000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2736830000/native-3606715f4c766d65033dbb8c-zip"}],"artifacts":[{"id":"native-d9ef01e90cb6fcf38ec05183-step","name":"2736830000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/da885061-09bb-4907-8542-e1dacc55063a/original/2736830000.stp","sourceSha256":"d9ef01e90cb6fcf38ec0518371d5551124426b09675888e378d4c0bd0cad9481","artifactSha256":"152fbb1e255ed409aeb0efefcede1f44a9600756ffeceeccacd821b8de46f42d","bytes":237274,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2736830000/native-d9ef01e90cb6fcf38ec05183-step","customerPrice":0},{"id":"native-32677962c94b96cef326d99e-zip","name":"2736830000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DXF"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/0424e9d6-edea-4f70-9ca7-aecc84e5b618/original/2736830000_DXF.zip","sourceSha256":"32677962c94b96cef326d99e52458dc97383e735d40ac85fee09d4b876a53ece","artifactSha256":"32677962c94b96cef326d99e52458dc97383e735d40ac85fee09d4b876a53ece","bytes":76903,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2736830000/native-32677962c94b96cef326d99e-zip","customerPrice":0},{"id":"native-3606715f4c766d65033dbb8c-zip","name":"2736830000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/62480735-aa97-4be3-a6c9-03d5fa98b1c7/original/2736830000_DWG.zip","sourceSha256":"3606715f4c766d65033dbb8cc5b1383dc2102b86e927421382604d3468469176","artifactSha256":"3606715f4c766d65033dbb8cc5b1383dc2102b86e927421382604d3468469176","bytes":86059,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2736830000/native-3606715f4c766d65033dbb8c-zip","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"A2T 2.5 3C N-FT — Feed-through terminal block / Multi-tier modular terminal, 2.5 mm², 800 V, 22 A, Number of levels: 2, dark beige, orange"},{"label":"Manufacturer","value":"Weidmüller"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"2736830000"},{"label":"Manufacturer reference","value":"2736830000"},{"label":"Manufacturer type","value":"A2T 2.5 3C N-FT"},{"label":"Available native formats","value":"DWG / DXF / STEP"},{"label":"Listed file formats","value":"DWG, DXF, STEP"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"2 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 3 files / 25 MiB daily; registered free: 100 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/weidmueller-article-2736830000/native-32677962c94b96cef326d99e-zip?asset=0771eb89cfb8c93e28761fe80262a15c9707ca7b5a6108d7b3e768438e5acd7d","relatedReferences":[{"name":"Terminal strip assembly","url":"https://eloragrid.ai/objects/terminal-strip"},{"name":"Cable gland","url":"https://eloragrid.ai/objects/ga-cable-gland"}],"fileChoiceGuidance":["Start with 2736830000. The files above belong to Weidmüller's A2T 2.5 3C N-FT — Feed-through terminal block / Multi-tier modular terminal, 2.5 mm², 800 V, 22 A, Number of levels: 2, dark beige, orange resource; match any model or option suffix in the filename to your selected unit.","Available here: STEP, ZIP. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"A terminal provides an identified point for joining wires to equipment or to other wires. Terminal strips organise those connections so they can be wired and checked.","example":"In a substation relay panel, numbered terminals connect the switchyard cables to the protection and control equipment.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Field wiring","Identified terminal connections","Panel equipment"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Weidmüller official source","url":"https://eshop.weidmueller.com.cn/en/a2t-2-5-3c-n-ft/p/2736830000/downloads#engineering-support"}],"profileId":"terminal"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/weidmueller-article-2736830000"}