{"id":"weidmueller-article-2807420000","name":"VPU AC II F 4 R 300/40 — Surge arrester power engineering AC (type 2) / Surge voltage arrester  (power supply systems) Surge protection, with remote contact, Type II, Type III, Low voltage network: TN-C-S, AC, 230 V","manufacturer":"Weidmüller","category":"power-supplies","description":"Weidmüller VPU AC II F 4 R 300/40 — Surge arrester power engineering AC (type 2) / Surge voltage arrester  (power supply systems) Surge protection, with remote contact, Type II, Type III, Low voltage network: TN-C-S, AC, 230 V. Manufacturer CAD files for power supplies equipment selection and layout, identified by article 2807420000.","equipment":["power supplies","VPU AC II F 4 R 300/40 — Surge arrester power engineering AC (type 2) / Surge voltage arrester  (power supply systems) Surge protection, with remote contact, Type II, Type III, Low voltage network: TN-C-S, AC, 230 V"],"keywords":["Weidmüller","VPU AC II F 4 R 300/40 — Surge arrester power engineering AC (type 2) / Surge voltage arrester  (power supply systems) Surge protection, with remote contact, Type II, Type III, Low voltage network: TN-C-S, AC, 230 V","2807420000","power supplies","DWG","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"2807420000","sourceUrl":"https://eshop.weidmueller.com.cn/en/vpu-ac-ii-f-4-r-30040/p/2807420000/downloads#engineering-support","officialEvidenceUrl":"https://eshop.weidmueller.com.cn/en/vpu-ac-ii-f-4-r-30040/p/2807420000/downloads#engineering-support","sourcePublisher":"Weidmüller","formats":["DWG","DXF","STEP"],"availability":"direct","accessNote":"Manufacturer CAD files for the listed equipment reference. Open the original files in compatible CAD software.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"2807420000","sourceUrl":"https://eshop.weidmueller.com.cn/en/vpu-ac-ii-f-4-r-30040/p/2807420000/downloads#engineering-support"},{"label":"Manufacturer type","value":"VPU AC II F 4 R 300/40","sourceUrl":"https://eshop.weidmueller.com.cn/en/vpu-ac-ii-f-4-r-30040/p/2807420000/downloads#engineering-support"},{"label":"Available native formats","value":"DWG / DXF / STEP","sourceUrl":"https://eshop.weidmueller.com.cn/en/vpu-ac-ii-f-4-r-30040/p/2807420000/downloads#engineering-support"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-2aed71dc5dc0a1fb3f9f5033-zip","name":"2807420000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/4cd73eef-1aff-4ba0-a2e8-4c85ff5e0e58/original/2807420000_DXF.zip","availability":"direct","sha256":"2aed71dc5dc0a1fb3f9f5033614d85fa016d6fda58022d5391edc5330a975133","bytes":58967,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"2807420000_DXF.zip","format":"ZIP","sha256":"2aed71dc5dc0a1fb3f9f5033614d85fa016d6fda58022d5391edc5330a975133","bytes":58967,"includes":["2807420000_DXF.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/4cd73eef-1aff-4ba0-a2e8-4c85ff5e0e58/original/2807420000_DXF.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["2807420000_back.DXF","2807420000_bottom.DXF","2807420000_front.DXF","2807420000_left.DXF","2807420000_right.DXF","2807420000_top.DXF"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2807420000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2807420000/native-2aed71dc5dc0a1fb3f9f5033-zip"},{"id":"native-3ac166e88d639aabc7c18c62-zip","name":"2807420000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/ab3645d6-1657-431a-b213-ccc3d915e964/original/2807420000_DWG.zip","availability":"direct","sha256":"3ac166e88d639aabc7c18c62643b38a31c8b142edf854bc86450f47665fea9c8","bytes":66813,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"2807420000_DWG.zip","format":"ZIP","sha256":"3ac166e88d639aabc7c18c62643b38a31c8b142edf854bc86450f47665fea9c8","bytes":66813,"includes":["2807420000_DWG.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/ab3645d6-1657-431a-b213-ccc3d915e964/original/2807420000_DWG.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["2807420000_back.DWG","2807420000_bottom.DWG","2807420000_front.DWG","2807420000_left.DWG","2807420000_right.DWG","2807420000_top.DWG"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2807420000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2807420000/native-3ac166e88d639aabc7c18c62-zip"},{"id":"native-f2ee49543727e4b806effadf-step","name":"2591280000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://assets.dam.weidmueller.com/assets/api/6a5c1fbf-9b89-4c10-a3bc-2eddbc2cc0d1/original/2591280000.stp","availability":"direct","sha256":"f2ee49543727e4b806effadfb0434029de7fb39fe51240ed30c4400d9ddb0e2d","bytes":2102264,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"2591280000.stp.zip","format":"ZIP","sha256":"85ce96e8e17dd99fb923fcc600580676f115988d269df24989033ae23b94b0c6","bytes":333349,"includes":["2591280000.stp"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/6a5c1fbf-9b89-4c10-a3bc-2eddbc2cc0d1/original/2591280000.stp","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2807420000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2807420000/native-f2ee49543727e4b806effadf-step"}],"artifacts":[{"id":"native-2aed71dc5dc0a1fb3f9f5033-zip","name":"2807420000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DXF"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/4cd73eef-1aff-4ba0-a2e8-4c85ff5e0e58/original/2807420000_DXF.zip","sourceSha256":"2aed71dc5dc0a1fb3f9f5033614d85fa016d6fda58022d5391edc5330a975133","artifactSha256":"2aed71dc5dc0a1fb3f9f5033614d85fa016d6fda58022d5391edc5330a975133","bytes":58967,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2807420000/native-2aed71dc5dc0a1fb3f9f5033-zip","customerPrice":0},{"id":"native-3ac166e88d639aabc7c18c62-zip","name":"2807420000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/ab3645d6-1657-431a-b213-ccc3d915e964/original/2807420000_DWG.zip","sourceSha256":"3ac166e88d639aabc7c18c62643b38a31c8b142edf854bc86450f47665fea9c8","artifactSha256":"3ac166e88d639aabc7c18c62643b38a31c8b142edf854bc86450f47665fea9c8","bytes":66813,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2807420000/native-3ac166e88d639aabc7c18c62-zip","customerPrice":0},{"id":"native-f2ee49543727e4b806effadf-step","name":"2591280000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/6a5c1fbf-9b89-4c10-a3bc-2eddbc2cc0d1/original/2591280000.stp","sourceSha256":"f2ee49543727e4b806effadfb0434029de7fb39fe51240ed30c4400d9ddb0e2d","artifactSha256":"85ce96e8e17dd99fb923fcc600580676f115988d269df24989033ae23b94b0c6","bytes":333349,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2807420000/native-f2ee49543727e4b806effadf-step","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"VPU AC II F 4 R 300/40 — Surge arrester power engineering AC (type 2) / Surge voltage arrester  (power supply systems) Surge protection, with remote contact, Type II, Type III, Low voltage network: TN-C-S, AC, 230 V"},{"label":"Manufacturer","value":"Weidmüller"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"2807420000"},{"label":"Manufacturer reference","value":"2807420000"},{"label":"Manufacturer type","value":"VPU AC II F 4 R 300/40"},{"label":"Available native formats","value":"DWG / DXF / STEP"},{"label":"Listed file formats","value":"DWG, DXF, STEP"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"2 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 3 files / 25 MiB daily; registered free: 100 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/weidmueller-article-2807420000/native-2aed71dc5dc0a1fb3f9f5033-zip?asset=f4dd817c249d9080ed13bf9ed53729d2c0f88abf12a624a516c87c8f33ceb6e8","relatedReferences":[{"name":"DIN-rail AC/DC power supply","url":"https://eloragrid.ai/objects/ga-din-rail-ac-dc-power-supply"},{"name":"AC UPS cabinet","url":"https://eloragrid.ai/objects/ga-ac-ups-cabinet"}],"fileChoiceGuidance":["Start with 2807420000. The files above belong to Weidmüller's VPU AC II F 4 R 300/40 — Surge arrester power engineering AC (type 2) / Surge voltage arrester  (power supply systems) Surge protection, with remote contact, Type II, Type III, Low voltage network: TN-C-S, AC, 230 V resource; match any model or option suffix in the filename to your selected unit.","Available here: ZIP, STEP. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"A surge protective device limits brief voltage spikes by providing a path for surge current under its designed conditions.","example":"At a substation cable interface, it can help limit a transient voltage reaching connected equipment.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Brief voltage spike","Surge protection responds","Voltage is limited"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Weidmüller official source","url":"https://eshop.weidmueller.com.cn/en/vpu-ac-ii-f-4-r-30040/p/2807420000/downloads#engineering-support"}],"profileId":"surge"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/weidmueller-article-2807420000"}