{"id":"weidmueller-article-2983610000","name":"VPU AC I 4 R 300/12.5 LH — Lightning current arrester power engineering AC (type 1) / Surge arrester, Type I, TN-C-S, TN-S, AC, 230 V","manufacturer":"Weidmüller","category":"transformers","description":"Weidmüller VPU AC I 4 R 300/12.5 LH — Lightning current arrester power engineering AC (type 1) / Surge arrester, Type I, TN-C-S, TN-S, AC, 230 V. Manufacturer CAD files for transformers equipment selection and layout, identified by article 2983610000.","equipment":["transformers","VPU AC I 4 R 300/12.5 LH — Lightning current arrester power engineering AC (type 1) / Surge arrester, Type I, TN-C-S, TN-S, AC, 230 V"],"keywords":["Weidmüller","VPU AC I 4 R 300/12.5 LH — Lightning current arrester power engineering AC (type 1) / Surge arrester, Type I, TN-C-S, TN-S, AC, 230 V","2983610000","transformers","DWG","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"2983610000","sourceUrl":"https://eshop.weidmueller.com.cn/en/vpu-ac-i-4-r-30012-5-lh/p/2983610000/downloads#engineering-support","officialEvidenceUrl":"https://eshop.weidmueller.com.cn/en/vpu-ac-i-4-r-30012-5-lh/p/2983610000/downloads#engineering-support","sourcePublisher":"Weidmüller","formats":["DWG","DXF","STEP"],"availability":"direct","accessNote":"Manufacturer CAD files for the listed equipment reference. Open the original files in compatible CAD software.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"2983610000","sourceUrl":"https://eshop.weidmueller.com.cn/en/vpu-ac-i-4-r-30012-5-lh/p/2983610000/downloads#engineering-support"},{"label":"Manufacturer type","value":"VPU AC I 4 R 300/12.5 LH","sourceUrl":"https://eshop.weidmueller.com.cn/en/vpu-ac-i-4-r-30012-5-lh/p/2983610000/downloads#engineering-support"},{"label":"Available native formats","value":"DWG / DXF / STEP","sourceUrl":"https://eshop.weidmueller.com.cn/en/vpu-ac-i-4-r-30012-5-lh/p/2983610000/downloads#engineering-support"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-7e833e8f90160db120948f0a-step","name":"2983610000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://assets.dam.weidmueller.com/assets/api/cfbb900d-826e-4a7d-aaa1-1fe46076a8dc/original/2983610000.stp","availability":"direct","sha256":"7e833e8f90160db120948f0a66b923dd46280df98aa663bdba320d3a968e2fe2","bytes":1111294,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"2983610000.stp.zip","format":"ZIP","sha256":"f69a4fc6ff48f3ab6abb3bf23edb4084d128000800af30b78670c10fa4577426","bytes":183732,"includes":["2983610000.stp"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/cfbb900d-826e-4a7d-aaa1-1fe46076a8dc/original/2983610000.stp","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2983610000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2983610000/native-7e833e8f90160db120948f0a-step"},{"id":"native-c15df411ad998bd67282e0a7-zip","name":"2983610000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/5cd316e9-c927-4ded-841d-3ece15b19054/original/2983610000_DXF.zip","availability":"direct","sha256":"c15df411ad998bd67282e0a7a4f9dc42163d551376d3f4cb58d6360cc2c945b5","bytes":62991,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"2983610000_DXF.zip","format":"ZIP","sha256":"c15df411ad998bd67282e0a7a4f9dc42163d551376d3f4cb58d6360cc2c945b5","bytes":62991,"includes":["2983610000_DXF.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/5cd316e9-c927-4ded-841d-3ece15b19054/original/2983610000_DXF.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["2983610000_back.DXF","2983610000_bottom.DXF","2983610000_front.DXF","2983610000_left.DXF","2983610000_right.DXF","2983610000_top.DXF"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2983610000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2983610000/native-c15df411ad998bd67282e0a7-zip"},{"id":"native-41af0c2d40dc9e8d3ee46197-zip","name":"2983610000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/06c99f07-3977-419d-b2d6-61d0cf6b3919/original/2983610000_DWG.zip","availability":"direct","sha256":"41af0c2d40dc9e8d3ee46197998ec9e4563afa347c1fba93946d2b5269d7e1f6","bytes":70096,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"2983610000_DWG.zip","format":"ZIP","sha256":"41af0c2d40dc9e8d3ee46197998ec9e4563afa347c1fba93946d2b5269d7e1f6","bytes":70096,"includes":["2983610000_DWG.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/06c99f07-3977-419d-b2d6-61d0cf6b3919/original/2983610000_DWG.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["2983610000_back.DWG","2983610000_bottom.DWG","2983610000_front.DWG","2983610000_left.DWG","2983610000_right.DWG","2983610000_top.DWG"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-2983610000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-2983610000/native-41af0c2d40dc9e8d3ee46197-zip"}],"artifacts":[{"id":"native-7e833e8f90160db120948f0a-step","name":"2983610000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/cfbb900d-826e-4a7d-aaa1-1fe46076a8dc/original/2983610000.stp","sourceSha256":"7e833e8f90160db120948f0a66b923dd46280df98aa663bdba320d3a968e2fe2","artifactSha256":"f69a4fc6ff48f3ab6abb3bf23edb4084d128000800af30b78670c10fa4577426","bytes":183732,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2983610000/native-7e833e8f90160db120948f0a-step","customerPrice":0},{"id":"native-c15df411ad998bd67282e0a7-zip","name":"2983610000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DXF"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/5cd316e9-c927-4ded-841d-3ece15b19054/original/2983610000_DXF.zip","sourceSha256":"c15df411ad998bd67282e0a7a4f9dc42163d551376d3f4cb58d6360cc2c945b5","artifactSha256":"c15df411ad998bd67282e0a7a4f9dc42163d551376d3f4cb58d6360cc2c945b5","bytes":62991,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2983610000/native-c15df411ad998bd67282e0a7-zip","customerPrice":0},{"id":"native-41af0c2d40dc9e8d3ee46197-zip","name":"2983610000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/06c99f07-3977-419d-b2d6-61d0cf6b3919/original/2983610000_DWG.zip","sourceSha256":"41af0c2d40dc9e8d3ee46197998ec9e4563afa347c1fba93946d2b5269d7e1f6","artifactSha256":"41af0c2d40dc9e8d3ee46197998ec9e4563afa347c1fba93946d2b5269d7e1f6","bytes":70096,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-2983610000/native-41af0c2d40dc9e8d3ee46197-zip","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"VPU AC I 4 R 300/12.5 LH — Lightning current arrester power engineering AC (type 1) / Surge arrester, Type I, TN-C-S, TN-S, AC, 230 V"},{"label":"Manufacturer","value":"Weidmüller"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"2983610000"},{"label":"Manufacturer reference","value":"2983610000"},{"label":"Manufacturer type","value":"VPU AC I 4 R 300/12.5 LH"},{"label":"Available native formats","value":"DWG / DXF / STEP"},{"label":"Listed file formats","value":"DWG, DXF, STEP"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"2 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 50 files / 512 MiB daily; registered free: 1,000 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/weidmueller-article-2983610000/native-c15df411ad998bd67282e0a7-zip?asset=59b971c629c8202624c910cfdb8ced464c6b9685da584f80faf5edd1eeabdb66","relatedReferences":[{"name":"Transformer envelope","url":"https://eloragrid.ai/objects/transformer-envelope"},{"name":"Control transformer","url":"https://eloragrid.ai/objects/ga-control-transformer"}],"fileChoiceGuidance":["Start with 2983610000. The files above belong to Weidmüller's VPU AC I 4 R 300/12.5 LH — Lightning current arrester power engineering AC (type 1) / Surge arrester, Type I, TN-C-S, TN-S, AC, 230 V resource; match any model or option suffix in the filename to your selected unit.","Available here: STEP, ZIP. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"A surge protective device limits brief voltage spikes by providing a path for surge current under its designed conditions.","example":"At a substation cable interface, it can help limit a transient voltage reaching connected equipment.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Brief voltage spike","Surge protection responds","Voltage is limited"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Weidmüller official source","url":"https://eshop.weidmueller.com.cn/en/vpu-ac-i-4-r-30012-5-lh/p/2983610000/downloads#engineering-support"}],"profileId":"surge"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/weidmueller-article-2983610000"}