{"id":"weidmueller-article-9526990000","name":"KLIPPON K71 EX — Ex metal housing / Ex metal housing, 280 x 230 x 111 mm, untreated, Flange plate: No, M6 torx stainless steel screws with slot","manufacturer":"Weidmüller","category":"enclosures","description":"Weidmüller KLIPPON K71 EX — Ex metal housing / Ex metal housing, 280 x 230 x 111 mm, untreated, Flange plate: No, M6 torx stainless steel screws with slot. Manufacturer CAD files for enclosures equipment selection and layout, identified by article 9526990000.","equipment":["enclosures","KLIPPON K71 EX — Ex metal housing / Ex metal housing, 280 x 230 x 111 mm, untreated, Flange plate: No, M6 torx stainless steel screws with slot"],"keywords":["Weidmüller","KLIPPON K71 EX — Ex metal housing / Ex metal housing, 280 x 230 x 111 mm, untreated, Flange plate: No, M6 torx stainless steel screws with slot","9526990000","enclosures","DWG","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"9526990000","sourceUrl":"https://eshop.weidmueller.com.cn/en/klippon-k71-ex/p/9526990000/downloads#engineering-support","officialEvidenceUrl":"https://eshop.weidmueller.com.cn/en/klippon-k71-ex/p/9526990000/downloads#engineering-support","sourcePublisher":"Weidmüller","formats":["DWG","DXF","STEP"],"availability":"direct","accessNote":"Manufacturer CAD files for the listed equipment reference. Open the original files in compatible CAD software.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"9526990000","sourceUrl":"https://eshop.weidmueller.com.cn/en/klippon-k71-ex/p/9526990000/downloads#engineering-support"},{"label":"Manufacturer type","value":"KLIPPON K71 EX","sourceUrl":"https://eshop.weidmueller.com.cn/en/klippon-k71-ex/p/9526990000/downloads#engineering-support"},{"label":"Available native formats","value":"DWG / DXF / STEP","sourceUrl":"https://eshop.weidmueller.com.cn/en/klippon-k71-ex/p/9526990000/downloads#engineering-support"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-7b3f780712c060e065501dcf-step","name":"9526990000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://assets.dam.weidmueller.com/assets/api/2dd2e73f-0797-425e-9379-6ba14699e0b8/original/9526990000.stp","availability":"direct","sha256":"7b3f780712c060e065501dcffb54c2450281c253eaa1bdd79a2cf1d59e557976","bytes":1991023,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"9526990000.stp.zip","format":"ZIP","sha256":"0913f2d03743036405d115ac87ab44a50c7c796ad544d5ee44dd5a2808c5cafb","bytes":339012,"includes":["9526990000.stp"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/2dd2e73f-0797-425e-9379-6ba14699e0b8/original/9526990000.stp","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-9526990000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-9526990000/native-7b3f780712c060e065501dcf-step"},{"id":"native-e0d07d0a87446961e2f7349e-zip","name":"9526990000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/d57f2d38-2b75-483a-b538-ecede2a6ddf3/original/9526990000_DXF.zip","availability":"direct","sha256":"e0d07d0a87446961e2f7349e0047f85edca7ea2a0b9a26b3266ab9b7ab9e95fc","bytes":58843,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"9526990000_DXF.zip","format":"ZIP","sha256":"e0d07d0a87446961e2f7349e0047f85edca7ea2a0b9a26b3266ab9b7ab9e95fc","bytes":58843,"includes":["9526990000_DXF.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/d57f2d38-2b75-483a-b538-ecede2a6ddf3/original/9526990000_DXF.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["9526990000_back.DXF","9526990000_bottom.DXF","9526990000_front.DXF","9526990000_left.DXF","9526990000_right.DXF","9526990000_top.DXF"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-9526990000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-9526990000/native-e0d07d0a87446961e2f7349e-zip"},{"id":"native-df70ce6f314c90dcaf947f4f-zip","name":"9526990000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/b47a0954-935c-4561-8c68-429a5e15623e/original/9526990000_DWG.zip","availability":"direct","sha256":"df70ce6f314c90dcaf947f4f95abf34b0f78b91f33d20b66066bf16fbb334f56","bytes":74141,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"9526990000_DWG.zip","format":"ZIP","sha256":"df70ce6f314c90dcaf947f4f95abf34b0f78b91f33d20b66066bf16fbb334f56","bytes":74141,"includes":["9526990000_DWG.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/b47a0954-935c-4561-8c68-429a5e15623e/original/9526990000_DWG.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["9526990000_back.DWG","9526990000_bottom.DWG","9526990000_front.DWG","9526990000_left.DWG","9526990000_right.DWG","9526990000_top.DWG"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-9526990000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-9526990000/native-df70ce6f314c90dcaf947f4f-zip"}],"artifacts":[{"id":"native-7b3f780712c060e065501dcf-step","name":"9526990000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/2dd2e73f-0797-425e-9379-6ba14699e0b8/original/9526990000.stp","sourceSha256":"7b3f780712c060e065501dcffb54c2450281c253eaa1bdd79a2cf1d59e557976","artifactSha256":"0913f2d03743036405d115ac87ab44a50c7c796ad544d5ee44dd5a2808c5cafb","bytes":339012,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-9526990000/native-7b3f780712c060e065501dcf-step","customerPrice":0},{"id":"native-e0d07d0a87446961e2f7349e-zip","name":"9526990000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DXF"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/d57f2d38-2b75-483a-b538-ecede2a6ddf3/original/9526990000_DXF.zip","sourceSha256":"e0d07d0a87446961e2f7349e0047f85edca7ea2a0b9a26b3266ab9b7ab9e95fc","artifactSha256":"e0d07d0a87446961e2f7349e0047f85edca7ea2a0b9a26b3266ab9b7ab9e95fc","bytes":58843,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-9526990000/native-e0d07d0a87446961e2f7349e-zip","customerPrice":0},{"id":"native-df70ce6f314c90dcaf947f4f-zip","name":"9526990000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/b47a0954-935c-4561-8c68-429a5e15623e/original/9526990000_DWG.zip","sourceSha256":"df70ce6f314c90dcaf947f4f95abf34b0f78b91f33d20b66066bf16fbb334f56","artifactSha256":"df70ce6f314c90dcaf947f4f95abf34b0f78b91f33d20b66066bf16fbb334f56","bytes":74141,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-9526990000/native-df70ce6f314c90dcaf947f4f-zip","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"KLIPPON K71 EX — Ex metal housing / Ex metal housing, 280 x 230 x 111 mm, untreated, Flange plate: No, M6 torx stainless steel screws with slot"},{"label":"Manufacturer","value":"Weidmüller"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"9526990000"},{"label":"Manufacturer reference","value":"9526990000"},{"label":"Manufacturer type","value":"KLIPPON K71 EX"},{"label":"Available native formats","value":"DWG / DXF / STEP"},{"label":"Listed file formats","value":"DWG, DXF, STEP"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"2 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 50 files / 512 MiB daily; registered free: up to 60 individual files/formats per 24 hours from first admission, subject to 1 GiB/UTC day and shared 10 GiB/day or lower delivery safeguards; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/weidmueller-article-9526990000/native-e0d07d0a87446961e2f7349e-zip?asset=c6aa378755f59e1a664931e549bcf1175b64937b4f58dceaa0b26338d8ec2864","relatedReferences":[{"name":"Wall-mounted junction enclosure","url":"https://eloragrid.ai/objects/ga-wall-mounted-junction-enclosure"},{"name":"Floor-standing enclosure","url":"https://eloragrid.ai/objects/ga-floor-standing-enclosure"},{"name":"Mounting plate","url":"https://eloragrid.ai/objects/mounting-plate"}],"fileChoiceGuidance":["Start with 9526990000. The files above belong to Weidmüller's KLIPPON K71 EX — Ex metal housing / Ex metal housing, 280 x 230 x 111 mm, untreated, Flange plate: No, M6 torx stainless steel screws with slot resource; match any model or option suffix in the filename to your selected unit.","Available here: STEP, ZIP. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"An enclosure houses equipment and its connections. Its construction provides the environmental and access protection specified for that enclosure.","example":"In a substation marshalling cabinet, the enclosure houses terminals and interfaces between switchyard cables and control-building wiring.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Equipment and wiring","Selected enclosure","Protected and accessible assembly"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Weidmüller official source","url":"https://eshop.weidmueller.com.cn/en/klippon-k71-ex/p/9526990000/downloads#engineering-support"}],"profileId":"enclosure"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/weidmueller-article-9526990000"}