# ANSI/IEEE Cam-operated limit switch form

Canonical URL: https://eloragrid.ai/symbols/ansi-cam-operated-limit-switch
Publisher: Elora Grid
Updated: 2026-10-28
Lookup label: LS CAM
Drawing use: Schematic
Reference families: IEEE / ANSI, Manufacturer

## Symbol convention

Convention: IEEE / ANSI
Form: Limit Switch Normally Open - Cam Driven
Autodesk IEEE Symbol Preview: Limit Switches, block HLS11S13. Matching functional counterpart linked separately. Independently drawn educational geometry; not a certified IEEE glyph or database identifier.
Related representation: [Cam-operated limit switch](https://eloragrid.ai/symbols/cam-operated-limit-switch)

IEEE-library form of cam-operated limit switch: a cam-operated limit switch changes its electrical contact state when a defined cam profile reaches the actuator.

## In plain English

### What does ANSI/IEEE Cam-operated limit switch form mean?

This reference locates cam-operated limit switch in Autodesk's IEEE-oriented limit switches family. A cam-operated limit switch changes its electrical contact state when a defined cam profile reaches the operating mechanism. Its position function depends on the documented cam and mechanism relationship. The public library uses HLS11S13 for its horizontal representation; this is a vendor block name, not an IEEE standards symbol number.

### A simple example

Read the operating mechanism and the contact reference state together. Cross-reference every associated contact to the same device and show which movement, signal or reset changes its condition; the symbol alone does not establish the complete switching sequence.

### What the drawings help you do

Link the cam position to the electrical contact schedule. Cam operation is a mechanical input, not an electrically programmed timer. The linked functional counterpart explains the same operating role in its own drawing context; agreement of every detailed convention mark is not asserted.

### This particular reference

IEEE-library form of cam-operated limit switch: a cam-operated limit switch changes its electrical contact state when a defined cam profile reaches the operating mechanism. Cam operation is a mechanical input, not an electrically programmed timer.

### Terms

- Normally open / normally closed: The contact state in the normal condition defined for the drawing.
- Signal: Electrical information passed between devices, rather than necessarily the main power supply.
- Rating: A value stating the conditions for which equipment is specified.

Concept diagram: Identify the device and form → Read the connections and state → Check the equipment reference
A guide to reading this reference. The original symbol illustration and its drawing notes appear below; these boxes are not a wiring diagram.

- [Autodesk IEEE Symbol Preview — Limit Switches](https://help.autodesk.com/cloudhelp/2021/ENU/AutoCAD-Electrical/files/GUID-C0135D6B-F4A5-4954-85E0-5B188E5FF5C9.htm)


## What it represents

This reference locates cam-operated limit switch in Autodesk's IEEE-oriented limit switches family. A cam-operated limit switch changes its electrical contact state when a defined cam profile reaches the actuator. Its position function depends on the documented cam and mechanism relationship. The public library uses HLS11S13 for its horizontal representation; this is a vendor block name, not an IEEE standards symbol number.
Read the operating mechanism and the contact reference state together. Cross-reference every associated contact to the same device and show which movement, signal or reset changes its condition; the symbol alone does not establish the complete switching sequence.
Link the cam position to the electrical contact schedule. Cam actuation is a mechanical input, not an electrically programmed timer. The linked functional counterpart explains the same operating role in its own drawing context; agreement of every detailed convention mark is not asserted.

## How to read it

- Link the cam position to the electrical contact schedule.
- The preview is an original explanation of this function. Match the actual drawing convention to its legend and the selected equipment documentation.

## Information to show or reference

- Reference cam detail
- Identify operated contact
- State normal mechanism position

## Important distinction

Cam actuation is a mechanical input, not an electrically programmed timer.

## Facts

- Convention evidence: Autodesk IEEE Symbol Preview: Limit Switches; published form: Limit Switch Normally Open - Cam Driven.
- Public vendor block: HLS11S13. Vendor library token, not an IEEE symbol number.
- Drawing role: Actuated indication
- Identifier status: The short label is a functional lookup label, not an assigned IEC or IEEE symbol number. Any separately listed Autodesk code is a verified vendor block name.
- Artwork scope: Original educational geometry. Exact standard graphics, product ratings and terminal pinouts are not certified.

## Public references

- [Autodesk IEEE Symbol Preview — Limit Switches](https://help.autodesk.com/cloudhelp/2021/ENU/AutoCAD-Electrical/files/GUID-C0135D6B-F4A5-4954-85E0-5B188E5FF5C9.htm) — Autodesk. Public IEEE-oriented Limit Switches table explicitly lists HLS11S13 as Limit Switch Normally Open - Cam Driven. This supports the vendor convention context, not reproduction of the publisher graphic.

## Graphic scope

Independent original educational concept illustration by Elora Grid. Not a certified standards graphic or manufacturer footprint. Unitless; not to scale. Original artwork licence: https://creativecommons.org/licenses/by/4.0/. Publisher material is linked only.