# ANSI/IEEE Combined line and phase voltmeter selector form

Canonical URL: https://eloragrid.ai/symbols/ansi-combined-line-and-phase-voltmeter-selector
Publisher: Elora Grid
Updated: 2026-10-28
Lookup label: HSW1S92
Drawing use: Schematic
Reference families: IEEE / ANSI, Manufacturer

## Symbol convention

Convention: IEEE / ANSI
Form: 3 Voltage Phase-to-Phase and Phase-to-Neutral Switch
Autodesk IEEE Symbol Preview: Miscellaneous Switches, block HSW1S92. Matching functional counterpart linked separately. Independently drawn educational geometry; not a certified IEEE glyph or database identifier.
Related representation: [Combined line and phase voltmeter selector](https://eloragrid.ai/symbols/iec-combined-line-and-phase-voltmeter-selector)

IEEE-library form of combined line and phase voltmeter selector: this representation identifies a selector covering phase-to-phase and phase-to-neutral voltage measurements.

## In plain English

### What does ANSI/IEEE Combined line and phase voltmeter selector form mean?

This reference locates combined line and phase voltmeter selector in Autodesk's IEEE-oriented miscellaneous switches family. This representation identifies a selector covering phase-to-phase and phase-to-neutral voltage measurements. One selector covers both line-to-line and line-to-neutral measurements. The measurement function changes with position even though the meter and its physical terminals remain the same. The public library uses HSW1S92 for its horizontal representation; this is a vendor block name, not an IEEE standards symbol number.

### A simple example

Read the operating mechanism and the contact reference state together. Cross-reference every associated contact to the same device and show which movement, signal or reset changes its condition; the symbol alone does not establish the complete switching sequence.

### What the drawings help you do

List the selected conductor pair or phase/reference path for every position. Use the selected switch’s contact programme instead of inferring connections from the face labels alone. Provide a position table specifying each measurement path. The symbol cannot replace the actual switch contact programme. The linked functional counterpart explains the same operating role in its own drawing context; agreement of every detailed convention mark is not asserted.

### This particular reference

IEEE-library form of combined line and phase voltmeter selector: this representation identifies a selector covering phase-to-phase and phase-to-neutral voltage measurements. The symbol cannot replace the actual switch contact programme.

### Terms

- Normally open / normally closed: The contact state in the normal condition defined for the drawing.
- Phase: One of the related AC waveforms in a power system.
- Terminal: An identified point where a conductor connects.

Concept diagram: Identify the device and form → Read the connections and state → Check the equipment reference
A guide to reading this reference. The original symbol illustration and its drawing notes appear below; these boxes are not a wiring diagram.

- [Autodesk IEEE Symbol Preview — Miscellaneous Switches](https://help.autodesk.com/cloudhelp/2021/ENU/AutoCAD-Electrical/files/GUID-278F6C21-B1A6-4EA1-A535-E78D53BBD10D.htm)


## What it represents

This reference locates combined line and phase voltmeter selector in Autodesk's IEEE-oriented miscellaneous switches family. This representation identifies a selector covering phase-to-phase and phase-to-neutral voltage measurements. One selector covers both line-to-line and line-to-neutral measurements. The measurement function changes with position even though the meter and its physical terminals remain the same. The public library uses HSW1S92 for its horizontal representation; this is a vendor block name, not an IEEE standards symbol number.
Read the operating mechanism and the contact reference state together. Cross-reference every associated contact to the same device and show which movement, signal or reset changes its condition; the symbol alone does not establish the complete switching sequence.
List the selected conductor pair or phase/reference path for every position. Use the selected switch’s contact programme instead of inferring connections from the face labels alone. Provide a position table specifying each measurement path. The symbol cannot replace the actual switch contact programme. The linked functional counterpart explains the same operating role in its own drawing context; agreement of every detailed convention mark is not asserted.

## How to read it

- Provide a position table specifying each measurement path.
- The symbol cannot replace the actual switch contact programme.

## Information to show or reference

- Identify the associated device, circuit or diagram boundary.
- Provide a position table specifying each measurement path.
- Cross-reference the equipment data, terminal mapping or operating-state legend needed to interpret the form.

## Important distinction

The symbol cannot replace the actual switch contact programme.

## Facts

- Convention evidence: Autodesk IEEE Symbol Preview: Miscellaneous Switches; published form: 3 Voltage Phase-to-Phase and Phase-to-Neutral Switch.
- Public vendor block: HSW1S92. Vendor library token, not an IEEE symbol number.
- Information added: Provide a position table specifying each measurement path.
- Preview: Independent educational concept; consult the publisher and applicable standard for the exact graphic
- Artwork scope: Original educational geometry. Exact standard graphics, product ratings and terminal pinouts are not certified.

## Public references

- [Autodesk IEEE Symbol Preview — Miscellaneous Switches](https://help.autodesk.com/cloudhelp/2021/ENU/AutoCAD-Electrical/files/GUID-278F6C21-B1A6-4EA1-A535-E78D53BBD10D.htm) — Autodesk. Public IEEE-oriented Miscellaneous Switches table explicitly lists HSW1S92 as 3 Voltage Phase-to-Phase and Phase-to-Neutral Switch. This supports the vendor convention context, not reproduction of the publisher graphic.

## Graphic scope

Independent original educational concept illustration by Elora Grid. Not a certified standards graphic or manufacturer footprint. Unitless; not to scale. Original artwork licence: https://creativecommons.org/licenses/by/4.0/. Publisher material is linked only.
