# ANSI/IEEE Phase-to-phase voltmeter selector form

Canonical URL: https://eloragrid.ai/symbols/ansi-phase-to-phase-voltmeter-selector
Publisher: Elora Grid
Updated: 2026-10-28
Lookup label: HSW1S90
Drawing use: Schematic
Reference families: IEEE / ANSI, Manufacturer

## Symbol convention

Convention: IEEE / ANSI
Form: 3 Voltage Phase Switch
Autodesk IEEE Symbol Preview: Miscellaneous Switches, block HSW1S90. Matching functional counterpart linked separately. Independently drawn educational geometry; not a certified IEEE glyph or database identifier.
Related representation: [Phase-to-phase voltmeter selector](https://eloragrid.ai/symbols/iec-phase-to-phase-voltmeter-selector)

IEEE-library form of phase-to-phase voltmeter selector: this representation identifies selection among phase-to-phase voltage measurement connections.

## In plain English

### What does ANSI/IEEE Phase-to-phase voltmeter selector form mean?

This reference locates phase-to-phase voltmeter selector in Autodesk's IEEE-oriented miscellaneous switches family. This representation identifies selection among phase-to-phase voltage measurement connections. The selector connects the meter to the documented line-to-line measurement pairs at its operating positions. It is a measurement interface, not the power switching device of the three-phase circuit. The public library uses HSW1S90 for its horizontal representation; this is a vendor block name, not an IEEE standards symbol number.

### A simple example

Read the operating mechanism and the contact reference state together. Cross-reference every associated contact to the same device and show which movement, signal or reset changes its condition; the symbol alone does not establish the complete switching sequence.

### What the drawings help you do

Provide the actual contact programme and measurement position labels. Identify any instrument-transformer secondary circuits that feed the selector. Document the selector position table and the meter connection. A measurement selector must not be mistaken for a three-phase power isolator. The linked functional counterpart explains the same operating role in its own drawing context; agreement of every detailed convention mark is not asserted.

### This particular reference

IEEE-library form of phase-to-phase voltmeter selector: this representation identifies selection among phase-to-phase voltage measurement connections. A measurement selector must not be mistaken for a three-phase power isolator.

### Terms

- Winding: A coil of conductor inside an electrical machine or transformer.
- Normally open / normally closed: The contact state in the normal condition defined for the drawing.
- Phase: One of the related AC waveforms in a power system.

Concept diagram: Identify the device and form → Read the connections and state → Check the equipment reference
A guide to reading this reference. The original symbol illustration and its drawing notes appear below; these boxes are not a wiring diagram.

- [Autodesk IEEE Symbol Preview — Miscellaneous Switches](https://help.autodesk.com/cloudhelp/2021/ENU/AutoCAD-Electrical/files/GUID-278F6C21-B1A6-4EA1-A535-E78D53BBD10D.htm)


## What it represents

This reference locates phase-to-phase voltmeter selector in Autodesk's IEEE-oriented miscellaneous switches family. This representation identifies selection among phase-to-phase voltage measurement connections. The selector connects the meter to the documented line-to-line measurement pairs at its operating positions. It is a measurement interface, not the power switching device of the three-phase circuit. The public library uses HSW1S90 for its horizontal representation; this is a vendor block name, not an IEEE standards symbol number.
Read the operating mechanism and the contact reference state together. Cross-reference every associated contact to the same device and show which movement, signal or reset changes its condition; the symbol alone does not establish the complete switching sequence.
Provide the actual contact programme and measurement position labels. Identify any instrument-transformer secondary circuits that feed the selector. Document the selector position table and the meter connection. A measurement selector must not be mistaken for a three-phase power isolator. The linked functional counterpart explains the same operating role in its own drawing context; agreement of every detailed convention mark is not asserted.

## How to read it

- Document the selector position table and the meter connection.
- A measurement selector must not be mistaken for a three-phase power isolator.

## Information to show or reference

- Identify the associated device, circuit or diagram boundary.
- Document the selector position table and the meter connection.
- Cross-reference the equipment data, terminal mapping or operating-state legend needed to interpret the form.

## Important distinction

A measurement selector must not be mistaken for a three-phase power isolator.

## Facts

- Convention evidence: Autodesk IEEE Symbol Preview: Miscellaneous Switches; published form: 3 Voltage Phase Switch.
- Public vendor block: HSW1S90. Vendor library token, not an IEEE symbol number.
- Information added: Document the selector position table and the meter connection.
- Preview: Independent educational concept; consult the publisher and applicable standard for the exact graphic
- Artwork scope: Original educational geometry. Exact standard graphics, product ratings and terminal pinouts are not certified.

## Public references

- [Autodesk IEEE Symbol Preview — Miscellaneous Switches](https://help.autodesk.com/cloudhelp/2021/ENU/AutoCAD-Electrical/files/GUID-278F6C21-B1A6-4EA1-A535-E78D53BBD10D.htm) — Autodesk. Public IEEE-oriented Miscellaneous Switches table explicitly lists HSW1S90 as 3 Voltage Phase Switch. This supports the vendor convention context, not reproduction of the publisher graphic.

## Graphic scope

Independent original educational concept illustration by Elora Grid. Not a certified standards graphic or manufacturer footprint. Unitless; not to scale. Original artwork licence: https://creativecommons.org/licenses/by/4.0/. Publisher material is linked only.