{"schemaVersion":1,"slug":"broken-delta-residual-input-interface","name":"Broken-delta residual input interface","kind":"symbol","abbreviation":"BRII","aliases":["Voltage-transformer secondary arrangements","substations Voltage-transformer secondary arrangements","substations","Substations","Broken-delta secondary output","Residual relay voltage"],"category":"measurement-protection","drawingTypes":["Schematic"],"referenceFamilies":["Manufacturer"],"summary":"Carries the documented broken-delta winding output to the selected residual-voltage input.","description":["Carries the documented broken-delta winding output to the selected residual-voltage input. A voltage-transformer secondary arrangement connects a defined primary voltage measurement to protection, metering or control inputs. Winding identity, fuse protection and the voltage reference must remain visible across the drawing.","In a substation bay, one voltage circuit can feed protection while a separately identified winding supplies metering. A voltage-selection circuit must make clear which bus or line measurement is being used. For this reference, the drawing identifies “Broken-delta secondary output” at the input and “Residual relay voltage” at the output. The source winding connection must be identified.","Show the primary measurement point, secondary connection, protective devices and relay reference. A missing measurement can resemble a real system disturbance unless the voltage-circuit health is supervised appropriately. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation."],"readingNotes":["Start at the named input: Broken-delta secondary output. Identify its source device or document and the state represented on the drawing.","Follow the named output: Residual relay voltage. Cross-reference its destination and separate the command from confirmation that the equipment responded.","The source winding connection must be identified.","Show the primary measurement point, secondary connection, protective devices and relay reference. A missing measurement can resemble a real system disturbance unless the voltage-circuit health is supervised appropriately."],"drawingChecklist":["Label the source and connection reference for broken-delta secondary output.","Identify the destination and defined state of residual relay voltage.","Record the equipment or control-document revision supporting this functional block.","Check this application limit in the project design: The source winding connection must be identified."],"distinction":"The source winding connection must be identified. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.","facts":[{"label":"Representation","value":"Functional block"},{"label":"Installation focus","value":"Substations"},{"label":"Input / boundary","value":"Broken-delta secondary output"},{"label":"Output / connection","value":"Residual relay voltage"},{"label":"Lookup label","value":"BRII is a library lookup label, not a standard device designation."}],"references":[{"sourceId":"instrument-transformers","relevance":"Public technical context for voltage-transformer secondary arrangements. Current and voltage measurement transformers and their secondary interfaces. The application text and educational graphic are independently authored; the publisher does not certify this representation."}],"related":["voltage-transformer","potential-test-switch","capacitive-vt-carrier-coupling-boundary"],"artwork":"pi26-broken-delta-residual-input-interface","publishedOn":"2026-11-03","updatedOn":"2026-11-03","provenance":"independent-public-research","representation":{"type":"functional-block","focus":"substations","family":"vt-secondary","input":"Broken-delta secondary output","output":"Residual relay voltage"},"plainEnglish":{"title":"What this block does","introduction":"Carries the documented broken-delta winding output to the selected residual-voltage input.","example":"In a substation bay, one voltage circuit can feed protection while a separately identified winding supplies metering. A voltage-selection circuit must make clear which bus or line measurement is being used. For this reference, the drawing identifies “Broken-delta secondary output” at the input and “Residual relay voltage” at the output. The source winding connection must be identified.","drawings":"Start at the named input: Broken-delta secondary output. Identify its source device or document and the state represented on the drawing. Follow the named output: Residual relay voltage. Cross-reference its destination and separate the command from confirmation that the equipment responded.","terms":[{"name":"Input","meaning":"Broken-delta secondary output"},{"name":"Output","meaning":"Residual relay voltage"},{"name":"Application reference","meaning":"An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections."}],"diagram":"flow","steps":["Broken-delta secondary output","BRII","Residual relay voltage"],"caption":"A reading guide. The entry's original illustration and input/output facts describe this application.","sources":[{"label":"Indoor current and voltage transformers","url":"https://www.abb.com/gb/en/areas/electrification/medium-voltage/grid-components/core-components/indoor-instrument-transformers"}],"profileId":"power-installation-vt-secondary"},"url":"https://eloragrid.ai/symbols/broken-delta-residual-input-interface","illustration":{"url":"https://eloragrid.ai/tools/electrical-library/illustrations/broken-delta-residual-input-interface.svg","scope":"Original educational concept; not an official standard graphic or product footprint","license":"https://creativecommons.org/licenses/by/4.0/"},"sources":[{"id":"instrument-transformers","title":"Indoor current and voltage transformers","publisher":"ABB","url":"https://www.abb.com/gb/en/areas/electrification/medium-voltage/grid-components/core-components/indoor-instrument-transformers","type":"manufacturer","scope":"Public current- and voltage-transformer product families. Ratings, terminals and dimensions depend on the model.","checkedOn":"2026-10-13","reuse":"link-only","relevance":"Public technical context for voltage-transformer secondary arrangements. Current and voltage measurement transformers and their secondary interfaces. The application text and educational graphic are independently authored; the publisher does not certify this representation."}]}