{"schemaVersion":1,"slug":"cable-transition-bay-interface","name":"Cable-transition bay interface","kind":"symbol","abbreviation":"CBI","aliases":["Switchyard bay circuit arrangements","switchyards Switchyard bay circuit arrangements","switchyards","Switchyards","Overhead-line circuit","Cable circuit interface"],"category":"power-distribution","drawingTypes":["Schematic"],"referenceFamilies":["Manufacturer"],"summary":"Marks the electrical transition between the assigned overhead and cable circuit sections.","description":["Marks the electrical transition between the assigned overhead and cable circuit sections. A bay circuit arrangement groups the switching, measuring and protection interfaces associated with a specific network circuit. A line bay, transformer bay and reactor bay share some devices but connect different kinds of primary equipment.","In a switchyard single-line drawing, the bay arrangement helps the reader follow the circuit from its bus connection to the external line, transformer or compensation equipment and identify the measurement boundaries along the path. For this reference, the drawing identifies “Overhead-line circuit” at the input and “Cable circuit interface” at the output. Termination and sheath details are separate drawings.","Preserve the actual order of primary connections, isolation points and CT locations. These conceptual arrangements do not establish equipment clearances, terminal layouts or an approved switching sequence. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation."],"readingNotes":["Start at the named input: Overhead-line circuit. Identify its source device or document and the state represented on the drawing.","Follow the named output: Cable circuit interface. Cross-reference its destination and separate the command from confirmation that the equipment responded.","Termination and sheath details are separate drawings.","Preserve the actual order of primary connections, isolation points and CT locations. These conceptual arrangements do not establish equipment clearances, terminal layouts or an approved switching sequence."],"drawingChecklist":["Label the source and connection reference for overhead-line circuit.","Identify the destination and defined state of cable circuit interface.","Record the equipment or control-document revision supporting this functional block.","Check this application limit in the project design: Termination and sheath details are separate drawings."],"distinction":"Termination and sheath details are separate drawings. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.","facts":[{"label":"Representation","value":"Functional block"},{"label":"Installation focus","value":"Switchyards"},{"label":"Input / boundary","value":"Overhead-line circuit"},{"label":"Output / connection","value":"Cable circuit interface"},{"label":"Lookup label","value":"CBI is a library lookup label, not a standard device designation."}],"references":[{"sourceId":"pi26-bus-schemes","relevance":"Public technical context for switchyard bay circuit arrangements. Bay arrangements and coordinated breaker controls. The application text and educational graphic are independently authored; the publisher does not certify this representation."}],"related":["circuit-breaker","current-transformer","line-end-voltage-measurement-interface"],"artwork":"pi26-cable-transition-bay-interface","publishedOn":"2026-11-03","updatedOn":"2026-11-03","provenance":"independent-public-research","representation":{"type":"functional-block","focus":"switchyards","family":"yard-bays","input":"Overhead-line circuit","output":"Cable circuit interface"},"plainEnglish":{"title":"What this block does","introduction":"Marks the electrical transition between the assigned overhead and cable circuit sections.","example":"In a switchyard single-line drawing, the bay arrangement helps the reader follow the circuit from its bus connection to the external line, transformer or compensation equipment and identify the measurement boundaries along the path. For this reference, the drawing identifies “Overhead-line circuit” at the input and “Cable circuit interface” at the output. Termination and sheath details are separate drawings.","drawings":"Start at the named input: Overhead-line circuit. Identify its source device or document and the state represented on the drawing. Follow the named output: Cable circuit interface. Cross-reference its destination and separate the command from confirmation that the equipment responded.","terms":[{"name":"Input","meaning":"Overhead-line circuit"},{"name":"Output","meaning":"Cable circuit interface"},{"name":"Application reference","meaning":"An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections."}],"diagram":"flow","steps":["Overhead-line circuit","CBI","Cable circuit interface"],"caption":"A reading guide. The entry's original illustration and input/output facts describe this application.","sources":[{"label":"SEL-451 protection, automation and bay control","url":"https://selinc.com/products/451/"}],"profileId":"power-installation-yard-bays"},"url":"https://eloragrid.ai/symbols/cable-transition-bay-interface","illustration":{"url":"https://eloragrid.ai/tools/electrical-library/illustrations/cable-transition-bay-interface.svg","scope":"Original educational concept; not an official standard graphic or product footprint","license":"https://creativecommons.org/licenses/by/4.0/"},"sources":[{"id":"pi26-bus-schemes","publisher":"SEL","title":"SEL-451 protection, automation and bay control","url":"https://selinc.com/products/451/","scope":"Bus arrangements, breaker control and bay-level coordination.","type":"manufacturer","checkedOn":"2026-11-03","reuse":"link-only","relevance":"Public technical context for switchyard bay circuit arrangements. Bay arrangements and coordinated breaker controls. The application text and educational graphic are independently authored; the publisher does not certify this representation."}]}