# Charging-motor supply-loss alarm

Canonical URL: https://eloragrid.ai/symbols/charging-motor-supply-loss-alarm
Publisher: Elora Grid
Updated: 2026-11-03
Lookup label: CSA
Drawing use: Schematic
Reference families: Manufacturer

Representation: Functional block
Installation focus: switchgear
Input: Motor-supply supervision
Output: Charging supply alarm

Reports loss of the electrical supply serving the charging motor.

## In plain English

### What this block does

Reports loss of the electrical supply serving the charging motor.

### A simple example

In a switchgear panel, a charging motor replenishes the mechanism after an operation. Supervisory contacts let the controller report an incomplete charge or repeated charging demand before an operator requests another operation. For this reference, the drawing identifies “Motor-supply supervision” at the input and “Charging supply alarm” at the output. Trip supply may remain available independently.

### What the drawings help you do

Start at the named input: Motor-supply supervision. Identify its source device or document and the state represented on the drawing. Follow the named output: Charging supply alarm. Cross-reference its destination and separate the command from confirmation that the equipment responded.

### Terms

- Input: Motor-supply supervision
- Output: Charging supply alarm
- Application reference: An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections.

Concept diagram: Motor-supply supervision → CSA → Charging supply alarm
A reading guide. The entry's original illustration and input/output facts describe this application.

- [Masterclad medium-voltage switchgear: circuit-breaker section interlocks](https://productinfo.se.com/masterclad_mv_switchgear_ib/6055-30-masterclad-15kv-mv-switchgear-ib/English/6055-30%20Masterclad%20MV%20Switchgear%20Indoor%20%28bookmap%29_DD00646805.xml/%24/Section6-CircuitBreakerSectionInter-58DD6EC7)


## What it represents

Reports loss of the electrical supply serving the charging motor. A stored-energy breaker mechanism has charging, release, indication and supervision functions. Motor supply, stored spring energy and the ability to complete an opening operation are separate drawing concerns.
In a switchgear panel, a charging motor replenishes the mechanism after an operation. Supervisory contacts let the controller report an incomplete charge or repeated charging demand before an operator requests another operation. For this reference, the drawing identifies “Motor-supply supervision” at the input and “Charging supply alarm” at the output. Trip supply may remain available independently.
Show the individual contacts and the relevant motor or release circuit. Supply voltage, charging time, operating duty and permissible alarms must follow the chosen mechanism documentation. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation.

## How to read it

- Start at the named input: Motor-supply supervision. Identify its source device or document and the state represented on the drawing.
- Follow the named output: Charging supply alarm. Cross-reference its destination and separate the command from confirmation that the equipment responded.
- Trip supply may remain available independently.
- Show the individual contacts and the relevant motor or release circuit. Supply voltage, charging time, operating duty and permissible alarms must follow the chosen mechanism documentation.

## Information to show or reference

- Label the source and connection reference for motor-supply supervision.
- Identify the destination and defined state of charging supply alarm.
- Record the equipment or control-document revision supporting this functional block.
- Check this application limit in the project design: Trip supply may remain available independently.

## Important distinction

Trip supply may remain available independently. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.

## Facts

- Representation: Functional block
- Installation focus: Switchgear
- Input / boundary: Motor-supply supervision
- Output / connection: Charging supply alarm
- Lookup label: CSA is a library lookup label, not a standard device designation.

## Public references

- [Masterclad medium-voltage switchgear: circuit-breaker section interlocks](https://productinfo.se.com/masterclad_mv_switchgear_ib/6055-30-masterclad-15kv-mv-switchgear-ib/English/6055-30%20Masterclad%20MV%20Switchgear%20Indoor%20%28bookmap%29_DD00646805.xml/%24/Section6-CircuitBreakerSectionInter-58DD6EC7) — Schneider Electric. Public technical context for stored-energy mechanism supervision. Breaker control, mechanism, position contacts, racking interlocks and test interfaces. The application text and educational graphic are independently authored; the publisher does not certify this representation.

## Graphic scope

Independent original educational concept illustration by Elora Grid. Not a certified standards graphic or manufacturer footprint. Unitless; not to scale. Original artwork licence: https://creativecommons.org/licenses/by/4.0/. Publisher material is linked only.