{"schemaVersion":1,"slug":"directional-comparison-blocking-interface","name":"Directional-comparison blocking interface","kind":"symbol","abbreviation":"DBI","aliases":["Substation protection scheme interfaces","substations Substation protection scheme interfaces","substations","Substations","Local direction and block signal","Blocked or enabled trip path"],"category":"measurement-protection","drawingTypes":["Schematic"],"referenceFamilies":["Manufacturer"],"summary":"Uses the assigned remote blocking information with the local directional protection decision.","description":["Uses the assigned remote blocking information with the local directional protection decision. A protection scheme combines measurements, decision elements and communication or trip outputs to protect a defined part of the network. A function number names a job; the scheme interface shows how that job connects to other equipment.","In a substation feeder bay, local current and voltage measurements may combine with a remote-end signal before the protection issues the assigned trip request. Backup actions use their own defined initiations and supervision. For this reference, the drawing identifies “Local direction and block signal” at the input and “Blocked or enabled trip path” at the output. Communication loss behavior must be defined.","Keep each protected zone, initiating quantity, blocking signal and trip destination distinct. Settings, communication performance and coordination require the approved protection study and selected relay documentation. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation."],"readingNotes":["Start at the named input: Local direction and block signal. Identify its source device or document and the state represented on the drawing.","Follow the named output: Blocked or enabled trip path. Cross-reference its destination and separate the command from confirmation that the equipment responded.","Communication loss behavior must be defined.","Keep each protected zone, initiating quantity, blocking signal and trip destination distinct. Settings, communication performance and coordination require the approved protection study and selected relay documentation."],"drawingChecklist":["Label the source and connection reference for local direction and block signal.","Identify the destination and defined state of blocked or enabled trip path.","Record the equipment or control-document revision supporting this functional block.","Check this application limit in the project design: Communication loss behavior must be defined."],"distinction":"Communication loss behavior must be defined. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.","facts":[{"label":"Representation","value":"Functional block"},{"label":"Installation focus","value":"Substations"},{"label":"Input / boundary","value":"Local direction and block signal"},{"label":"Output / connection","value":"Blocked or enabled trip path"},{"label":"Lookup label","value":"DBI is a library lookup label, not a standard device designation."}],"references":[{"sourceId":"pub-function-sel-line","relevance":"Public technical context for substation protection scheme interfaces. Line protection, breaker failure, communications and protection coordination. The application text and educational graphic are independently authored; the publisher does not certify this representation."}],"related":["50bf-circuit-breaker-failure-protection","87b-busbar-differential-protection","direct-transfer-trip-receive-interface"],"artwork":"pi26-directional-comparison-blocking-interface","publishedOn":"2026-11-03","updatedOn":"2026-11-03","provenance":"independent-public-research","representation":{"type":"functional-block","focus":"substations","family":"protection-schemes","input":"Local direction and block signal","output":"Blocked or enabled trip path"},"plainEnglish":{"title":"What this block does","introduction":"Uses the assigned remote blocking information with the local directional protection decision.","example":"In a substation feeder bay, local current and voltage measurements may combine with a remote-end signal before the protection issues the assigned trip request. Backup actions use their own defined initiations and supervision. For this reference, the drawing identifies “Local direction and block signal” at the input and “Blocked or enabled trip path” at the output. Communication loss behavior must be defined.","drawings":"Start at the named input: Local direction and block signal. Identify its source device or document and the state represented on the drawing. Follow the named output: Blocked or enabled trip path. Cross-reference its destination and separate the command from confirmation that the equipment responded.","terms":[{"name":"Input","meaning":"Local direction and block signal"},{"name":"Output","meaning":"Blocked or enabled trip path"},{"name":"Application reference","meaning":"An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections."}],"diagram":"flow","steps":["Local direction and block signal","DBI","Blocked or enabled trip path"],"caption":"A reading guide. The entry's original illustration and input/output facts describe this application.","sources":[{"label":"SEL-411L line differential protection overview","url":"https://selinc.com/products/411l/"}],"profileId":"power-installation-protection-schemes"},"url":"https://eloragrid.ai/symbols/directional-comparison-blocking-interface","illustration":{"url":"https://eloragrid.ai/tools/electrical-library/illustrations/directional-comparison-blocking-interface.svg","scope":"Original educational concept; not an official standard graphic or product footprint","license":"https://creativecommons.org/licenses/by/4.0/"},"sources":[{"id":"pub-function-sel-line","title":"SEL-411L line differential protection overview","publisher":"Schweitzer Engineering Laboratories","url":"https://selinc.com/products/411l/","type":"manufacturer","scope":"Public explanation of communication-assisted line current differential protection and the associated terminal measurements. Product diagrams and technical papers remain on the publisher site.","checkedOn":"2026-10-13","reuse":"link-only","relevance":"Public technical context for substation protection scheme interfaces. Line protection, breaker failure, communications and protection coordination. The application text and educational graphic are independently authored; the publisher does not certify this representation."}]}