# Emergency-lighting common-failure interface

Canonical URL: https://eloragrid.ai/symbols/emergency-lighting-common-failure-interface
Publisher: Elora Grid
Updated: 2026-11-03
Lookup label: ECI
Drawing use: Schematic
Reference families: Manufacturer

Representation: Functional block
Installation focus: switchrooms
Input: Lighting monitoring fault
Output: Room lighting-failure alarm

Receives the defined failure indication from the assigned emergency-lighting monitoring system.

## In plain English

### What this block does

Receives the defined failure indication from the assigned emergency-lighting monitoring system.

### A simple example

In a switchroom, a normal lighting branch may be switched locally while the specified emergency luminaires remain connected to their own backed-up or integral supply. For this reference, the drawing identifies “Lighting monitoring fault” at the input and “Room lighting-failure alarm” at the output. The monitored scope must identify the affected fittings.

### What the drawings help you do

Start at the named input: Lighting monitoring fault. Identify its source device or document and the state represented on the drawing. Follow the named output: Room lighting-failure alarm. Cross-reference its destination and separate the command from confirmation that the equipment responded.

### Terms

- Input: Lighting monitoring fault
- Output: Room lighting-failure alarm
- Application reference: An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections.

Concept diagram: Lighting monitoring fault → ECI → Room lighting-failure alarm
A reading guide. The entry's original illustration and input/output facts describe this application.

- [Indoor substation: lighting, fire and auxiliary services](https://www.electrical-installation.org/enwiki/Indoor_substation)


## What it represents

Receives the defined failure indication from the assigned emergency-lighting monitoring system. Lighting and access interfaces coordinate the electrical-room service circuits and their supervision. Normal lighting, emergency illumination and access indication have different power sources and purposes.
In a switchroom, a normal lighting branch may be switched locally while the specified emergency luminaires remain connected to their own backed-up or integral supply. For this reference, the drawing identifies “Lighting monitoring fault” at the input and “Room lighting-failure alarm” at the output. The monitored scope must identify the affected fittings.
Identify the lighting supply type, controlled circuit and the meaning of any test or failure output. A drawing symbol does not establish illumination levels, emergency duration or an approved egress arrangement. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation.

## How to read it

- Start at the named input: Lighting monitoring fault. Identify its source device or document and the state represented on the drawing.
- Follow the named output: Room lighting-failure alarm. Cross-reference its destination and separate the command from confirmation that the equipment responded.
- The monitored scope must identify the affected fittings.
- Identify the lighting supply type, controlled circuit and the meaning of any test or failure output. A drawing symbol does not establish illumination levels, emergency duration or an approved egress arrangement.

## Information to show or reference

- Label the source and connection reference for lighting monitoring fault.
- Identify the destination and defined state of room lighting-failure alarm.
- Record the equipment or control-document revision supporting this functional block.
- Check this application limit in the project design: The monitored scope must identify the affected fittings.

## Important distinction

The monitored scope must identify the affected fittings. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.

## Facts

- Representation: Functional block
- Installation focus: Switchrooms
- Input / boundary: Lighting monitoring fault
- Output / connection: Room lighting-failure alarm
- Lookup label: ECI is a library lookup label, not a standard device designation.

## Public references

- [Indoor substation: lighting, fire and auxiliary services](https://www.electrical-installation.org/enwiki/Indoor_substation) — Schneider Electric. Public technical context for switchroom lighting and access interfaces. Lighting, emergency lighting, fire provisions and substation auxiliary services. Original cause-and-effect examples require project design. The application text and educational graphic are independently authored; the publisher does not certify this representation.