{"schemaVersion":1,"slug":"essential-service-feeder-trip-indication","name":"Essential-service feeder trip indication","kind":"symbol","abbreviation":"EFTI","aliases":["Switchroom auxiliary AC distribution","switchrooms Switchroom auxiliary AC distribution","switchrooms","Switchrooms","Branch protective-device status","Essential feeder fault alarm"],"category":"installation-communications","drawingTypes":["Schematic"],"referenceFamilies":["Manufacturer"],"summary":"Identifies an operated protective device on the assigned essential service branch.","description":["Identifies an operated protective device on the assigned essential service branch. An auxiliary AC distribution diagram identifies the supplies serving room services and control-support equipment. Essential, backed-up and ordinary circuits can have different source paths and operating priorities.","In a switchroom, the lighting, service sockets, charger input and room cooling may be fed from different auxiliary branches. A source change must preserve the identities of loads that require continuity. For this reference, the drawing identifies “Branch protective-device status” at the input and “Essential feeder fault alarm” at the output. Alarm naming must identify the actual branch.","Label source, branch protection and load purpose. The arrangement does not establish conductor sizes, protection settings or installation compliance; it links the operating role to the selected equipment schedule. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation."],"readingNotes":["Start at the named input: Branch protective-device status. Identify its source device or document and the state represented on the drawing.","Follow the named output: Essential feeder fault alarm. Cross-reference its destination and separate the command from confirmation that the equipment responded.","Alarm naming must identify the actual branch.","Label source, branch protection and load purpose. The arrangement does not establish conductor sizes, protection settings or installation compliance; it links the operating role to the selected equipment schedule."],"drawingChecklist":["Label the source and connection reference for branch protective-device status.","Identify the destination and defined state of essential feeder fault alarm.","Record the equipment or control-document revision supporting this functional block.","Check this application limit in the project design: Alarm naming must identify the actual branch."],"distinction":"Alarm naming must identify the actual branch. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.","facts":[{"label":"Representation","value":"Functional block"},{"label":"Installation focus","value":"Switchrooms"},{"label":"Input / boundary","value":"Branch protective-device status"},{"label":"Output / connection","value":"Essential feeder fault alarm"},{"label":"Lookup label","value":"EFTI is a library lookup label, not a standard device designation."}],"references":[{"sourceId":"pi26-station-power","relevance":"Public technical context for switchroom auxiliary ac distribution. Independent AC and DC sources for station auxiliary power. The application text and educational graphic are independently authored; the publisher does not certify this representation."}],"related":["ga-panel-service-outlet","ac-uninterruptible-power-supply","auxiliary-board-load-shedding-input"],"artwork":"pi26-essential-service-feeder-trip-indication","publishedOn":"2026-11-03","updatedOn":"2026-11-03","provenance":"independent-public-research","representation":{"type":"functional-block","focus":"switchrooms","family":"room-ac","input":"Branch protective-device status","output":"Essential feeder fault alarm"},"plainEnglish":{"title":"What this block does","introduction":"Identifies an operated protective device on the assigned essential service branch.","example":"In a switchroom, the lighting, service sockets, charger input and room cooling may be fed from different auxiliary branches. A source change must preserve the identities of loads that require continuity. For this reference, the drawing identifies “Branch protective-device status” at the input and “Essential feeder fault alarm” at the output. Alarm naming must identify the actual branch.","drawings":"Start at the named input: Branch protective-device status. Identify its source device or document and the state represented on the drawing. Follow the named output: Essential feeder fault alarm. Cross-reference its destination and separate the command from confirmation that the equipment responded.","terms":[{"name":"Input","meaning":"Branch protective-device status"},{"name":"Output","meaning":"Essential feeder fault alarm"},{"name":"Application reference","meaning":"An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections."}],"diagram":"flow","steps":["Branch protective-device status","EFTI","Essential feeder fault alarm"],"caption":"A reading guide. The entry's original illustration and input/output facts describe this application.","sources":[{"label":"SEL-RPM redundant power module","url":"https://selinc.com/products/RPM/"}],"profileId":"power-installation-room-ac"},"url":"https://eloragrid.ai/symbols/essential-service-feeder-trip-indication","illustration":{"url":"https://eloragrid.ai/tools/electrical-library/illustrations/essential-service-feeder-trip-indication.svg","scope":"Original educational concept; not an official standard graphic or product footprint","license":"https://creativecommons.org/licenses/by/4.0/"},"sources":[{"id":"pi26-station-power","publisher":"SEL","title":"SEL-RPM redundant power module","url":"https://selinc.com/products/RPM/","scope":"Independent AC and DC sources for station auxiliary power.","type":"manufacturer","checkedOn":"2026-11-03","reuse":"link-only","relevance":"Public technical context for switchroom auxiliary ac distribution. Independent AC and DC sources for station auxiliary power. The application text and educational graphic are independently authored; the publisher does not certify this representation."}]}