{"schemaVersion":1,"slug":"ga-fp-mp-10-60f98a014986","name":"Hensel FP_MP_10 enclosure mounting subpanel","kind":"object","abbreviation":"FP_MP_10","aliases":["Hensel FP_MP_10 enclosure mounting subpanel GA","FP_MP_10 general arrangement","FP_MP_10 equipment layout"],"category":"equipment-layouts","drawingTypes":["GA"],"referenceFamilies":["Manufacturer"],"summary":"FP_MP_10 enclosure mounting subpanel arrangement: mounting, interface and service-space coordination.","description":["FP_MP_10 is the drawing identifier for enclosure mounting subpanel in Hensel's ENYSTAR enclosure and distribution-system STEP collection. A mounting subpanel supports selected equipment inside an enclosure. Its usable mounting area, fixing interfaces and removal route are separate from the external enclosure outline.","For example, in a control cabinet with a removable equipment mounting plate, use the FP_MP_10 reference to coordinate enclosure mounting points, equipment fixing and plate removal. Show the neighbouring equipment and the connection route so the installer can understand the intended arrangement.","Use the reviewed native drawing identified as ENYSTAR_Montageplatten/FP_MP_10.stp for the exact physical details. Locate the named file in its original manufacturer archive. Manufacturer drawing previews are shown only when an exact approved source is available. Any illustrative 3D view is a separate concept and is not to scale; use the selected manufacturer documents for dimensions, ratings and installation details."],"readingNotes":["Keep enclosure mounting points, equipment fixing and plate removal visible in the layout.","This reference concerns the named FP_MP_10 drawing and its enclosure mounting subpanel role. A drawing in the same collection is not automatic evidence of compatible terminals, mounts or electrical performance."],"drawingChecklist":["Match FP_MP_10, the native drawing identity and the project equipment schedule.","Confirm the exact compatible enclosure and the selected plate arrangement.","Coordinate enclosure mounting points, equipment fixing and plate removal with neighbouring equipment.","Confirm the current manufacturer installation instructions, selected revision and any required mounting or clearance details."],"distinction":"This reference concerns the named FP_MP_10 drawing and its enclosure mounting subpanel role. A drawing in the same collection is not automatic evidence of compatible terminals, mounts or electrical performance.","facts":[{"label":"Manufacturer source","value":"Hensel"},{"label":"Native drawing identity","value":"FP_MP_10"},{"label":"Reviewed equipment role","value":"enclosure mounting subpanel"},{"label":"CAD scope","value":"ENYSTAR enclosure and distribution-system STEP"},{"label":"Preview scope","value":"Source-matched manufacturer drawings where available; illustrative 3D is separate and not to scale"}],"references":[{"sourceId":"double-ga-europe-hensel-enystar","relevance":"Official source collection and exact native drawing identity, with the equipment role checked against native content or the narrowly defined source family."}],"related":["mounting-plate","ga-equipment-maintenance-envelope"],"artwork":"concept-ga-fp-mp-10-60f98a014986","publishedOn":"2026-10-29","updatedOn":"2026-10-29","provenance":"independent-public-research","plainEnglish":{"title":"What it does","introduction":"FP_MP_10 is the drawing identifier for enclosure mounting subpanel in Hensel's ENYSTAR enclosure and distribution-system STEP collection. A mounting subpanel supports selected equipment inside an enclosure. Its usable mounting area, fixing interfaces and removal route are separate from the external enclosure outline.","example":"For example, in a microgrid installation with a control cabinet with a removable equipment mounting plate, use the FP_MP_10 reference to coordinate enclosure mounting points, equipment fixing and plate removal. Show the neighbouring equipment and the connection route so the installer can understand the intended arrangement.","drawings":"Use the reviewed native drawing identified as ENYSTAR_Montageplatten/FP_MP_10.stp for the exact physical details. Locate the named file in its original manufacturer archive. Manufacturer drawing previews are shown only when an exact approved source is available. Any illustrative 3D view is a separate concept and is not to scale; use the selected manufacturer documents for dimensions, ratings and installation details.","checklist":["Match FP_MP_10, the native drawing identity and the project equipment schedule.","Confirm the exact compatible enclosure and the selected plate arrangement.","Coordinate enclosure mounting points, equipment fixing and plate removal with neighbouring equipment.","Confirm the current manufacturer installation instructions, selected revision and any required mounting or clearance details."],"terms":[{"name":"Drawing identity","meaning":"The named manufacturer drawing used to identify the intended physical configuration."},{"name":"Interface","meaning":"The place where this part mounts, connects or meets another selected part."},{"name":"Service space","meaning":"The area needed to reach, disconnect or remove the selected equipment as instructed."}],"diagram":"flow","steps":["Identify FP_MP_10","Coordinate enclosure mounting subpanel","Confirm the selected installation"],"caption":"A practical coordination sequence for this named equipment reference. It is not an electrical connection diagram.","sources":[{"label":"Hensel ENYSTAR enclosure and distribution-system STEP official CAD source","url":"https://www.hensel-electric.de/de-de/service/downloads/digitale-produktdaten/3d-step.php"}],"profileId":"reviewed-electrical-equipment-20261029"},"url":"https://eloragrid.ai/objects/ga-fp-mp-10-60f98a014986","illustration":{"url":"https://eloragrid.ai/tools/electrical-library/equipment-preview/ga-fp-mp-10-60f98a014986","scope":"Equipment preview: manufacturer drawing where available, otherwise a 3D thumbnail. Original object icon exports are removed."},"drawings":[],"sources":[{"id":"double-ga-europe-hensel-enystar","title":"Hensel ENYSTAR enclosure and distribution-system STEP official CAD source","publisher":"Hensel","url":"https://www.hensel-electric.de/de-de/service/downloads/digitale-produktdaten/3d-step.php","type":"manufacturer","scope":"Published source collection, exact native identities and physical component roles. No source geometry is reproduced in the educational artwork.","checkedOn":"2026-10-29","reuse":"link-only","relevance":"Official source collection and exact native drawing identity, with the equipment role checked against native content or the narrowly defined source family."}]}