# IEC selector-switch contact: 4 stable positions key selector normally closed-rotating in 2 ways

Canonical URL: https://eloragrid.ai/symbols/iec-selector-switch-contact-4-stable-positions-key-selector-normally-closed-rotating-in-2-ways
Publisher: Elora Grid
Updated: 2026-10-28
Lookup label: SS
Drawing use: Schematic
Reference families: IEC, Manufacturer

## Symbol convention

Convention: IEC
Form: 4 Stable Positions Key Selector Normally Closed-Rotating in 2 Ways
Autodesk IEC-60617 Symbol Preview: 4 Position Selector Switches, HSS12S50 / VSS12S50. This identifies the publisher's library context; exact IEC graphics and database identities are not asserted.

Selector-switch contact form: 4 Stable Positions Key Selector Normally Closed-Rotating in 2 Ways.

## In plain English

### What does IEC selector-switch contact: 4 stable positions key selector normally closed-rotating in 2 ways mean?

A rotary selector has discrete handle positions and one or more contact blocks driven by its mechanism. A contact shown as normally open or normally closed describes the stated reference position; it does not give the whole switching table across the remaining positions. This entry identifies the 4 stable positions key selector normally closed-rotating in 2 ways form in the publisher's IEC-context family.

### A simple example

For a local/off/remote selector, prepare a contact-versus-position chart alongside the schematic. The chart tells the installer which input is active at each handle setting, while spring-return, maintained and key-operated marks explain how the operator reaches or leaves that setting. The normally-closed designation starts with a conducting output or closed contact in the documented reference condition; operation changes that state. The selected key-selector form permits operating movement in both rotary directions; the position table must remain consistent in either approach direction.

### What the drawings help you do

A vendor neutral-position number must be read with that vendor form and the project legend. It does not automatically establish a key-removal position, a contact overlap or an off state. Those details need their own table or equipment reference.

### This particular reference

Selector-switch contact form: 4 Stable Positions Key Selector Normally Closed-Rotating in 2 Ways. This entry adds the 4 stable positions key selector normally closed-rotating in 2 ways detail to the broader selector-switch contact family. A vendor neutral-position number must be read with that vendor form and the project legend. It does not automatically establish a key-removal position, a contact overlap or an off state. Those details need their own table or equipment reference.

### Terms

- Normally open / normally closed: The contact state in the normal condition defined for the drawing.
- Signal: Electrical information passed between devices, rather than necessarily the main power supply.
- Rating: A value stating the conditions for which equipment is specified.

Concept diagram: Identify the device and form → Read the connections and state → Check the equipment reference
A guide to reading this reference. The original symbol illustration and its drawing notes appear below; these boxes are not a wiring diagram.

- [AutoCAD Electrical: Four-position selectors](https://help.autodesk.com/cloudhelp/2021/ENU/AutoCAD-Electrical/files/GUID-09243080-0BE8-4401-8E79-11156DF1CDDF.htm)


## What it represents

A rotary selector has discrete handle positions and one or more contact blocks driven by its mechanism. A contact shown as normally open or normally closed describes the stated reference position; it does not give the whole switching table across the remaining positions. This entry identifies the 4 stable positions key selector normally closed-rotating in 2 ways form in the publisher's IEC-context family.
For a local/off/remote selector, prepare a contact-versus-position chart alongside the schematic. The chart tells the installer which input is active at each handle setting, while spring-return, maintained and key-operated marks explain how the operator reaches or leaves that setting. The normally-closed designation starts with a conducting output or closed contact in the documented reference condition; operation changes that state. The selected key-selector form permits operating movement in both rotary directions; the position table must remain consistent in either approach direction.
A vendor neutral-position number must be read with that vendor form and the project legend. It does not automatically establish a key-removal position, a contact overlap or an off state. Those details need their own table or equipment reference.

## How to read it

- The normally-closed designation starts with a conducting output or closed contact in the documented reference condition; operation changes that state.
- The selected key-selector form permits operating movement in both rotary directions; the position table must remain consistent in either approach direction.
- A vendor neutral-position number must be read with that vendor form and the project legend. It does not automatically establish a key-removal position, a contact overlap or an off state. Those details need their own table or equipment reference.

## Information to show or reference

- Label every handle position and preserve its reference orientation.
- Cross-reference a contact-versus-position chart.
- State maintained positions, return directions and any key-removal conditions.

## Important distinction

This entry adds the 4 stable positions key selector normally closed-rotating in 2 ways detail to the broader selector-switch contact family. A vendor neutral-position number must be read with that vendor form and the project legend. It does not automatically establish a key-removal position, a contact overlap or an off state. Those details need their own table or equipment reference.

## Facts

- Drawing form: 4 Stable Positions Key Selector Normally Closed-Rotating in 2 Ways
- Public vendor block names: HSS12S50 / VSS12S50. Autodesk identifiers, not standards database IDs.
- Drawing purpose: selector-switch contact
- Graphic scope: Independently authored educational illustration; not certified standard geometry, a terminal pinout or a product footprint.

## Public references

- [AutoCAD Electrical: Four-position selectors](https://help.autodesk.com/cloudhelp/2021/ENU/AutoCAD-Electrical/files/GUID-09243080-0BE8-4401-8E79-11156DF1CDDF.htm) — Autodesk. Public 4 Position Selector Switches table explicitly lists HSS12S50 / VSS12S50 with this operating or connection form. Vendor graphics are linked, not copied.

## Graphic scope

Independent original educational concept illustration by Elora Grid. Not a certified standards graphic or manufacturer footprint. Unitless; not to scale. Original artwork licence: https://creativecommons.org/licenses/by/4.0/. Publisher material is linked only.