# Microgrid active-power ramp limiter

Canonical URL: https://eloragrid.ai/symbols/microgrid-active-power-ramp-limiter
Publisher: Elora Grid
Updated: 2026-11-03
Lookup label: MARL
Drawing use: Schematic
Reference families: Manufacturer

Representation: Functional block
Installation focus: microgrids
Input: Requested power target
Output: Rate-limited target

Constrains the rate of change of the assigned dispatch target according to its configured limits.

## In plain English

### What this block does

Constrains the rate of change of the assigned dispatch target according to its configured limits.

### A simple example

In a microgrid with solar generation, a battery and generators, the controller can allocate an import/export target among the available resources while reserving the power needed for operating disturbances. For this reference, the drawing identifies “Requested power target” at the input and “Rate-limited target” at the output. Actual resource response can differ from the target.

### What the drawings help you do

Start at the named input: Requested power target. Identify its source device or document and the state represented on the drawing. Follow the named output: Rate-limited target. Cross-reference its destination and separate the command from confirmation that the equipment responded.

### Terms

- Input: Requested power target
- Output: Rate-limited target
- Application reference: An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections.

Concept diagram: Requested power target → MARL → Rate-limited target
A reading guide. The entry's original illustration and input/output facts describe this application.

- [Microgrid control systems](https://selinc.com/services/microgrids-power-management/microgrid-control-systems/)


## What it represents

Constrains the rate of change of the assigned dispatch target according to its configured limits. Active-power dispatch allocates the electrical work performed by the microgrid resources. A total site target, a resource power limit and the actual measured contribution are different quantities that must be connected clearly in the diagram.
In a microgrid with solar generation, a battery and generators, the controller can allocate an import/export target among the available resources while reserving the power needed for operating disturbances. For this reference, the drawing identifies “Requested power target” at the input and “Rate-limited target” at the output. Actual resource response can differ from the target.
Identify the measurement boundary, power sign convention, resource limits and target priority. An original control block does not supply dispatch settings, a financial operating policy or proof of grid-code compliance. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation.

## How to read it

- Start at the named input: Requested power target. Identify its source device or document and the state represented on the drawing.
- Follow the named output: Rate-limited target. Cross-reference its destination and separate the command from confirmation that the equipment responded.
- Actual resource response can differ from the target.
- Identify the measurement boundary, power sign convention, resource limits and target priority. An original control block does not supply dispatch settings, a financial operating policy or proof of grid-code compliance.

## Information to show or reference

- Label the source and connection reference for requested power target.
- Identify the destination and defined state of rate-limited target.
- Record the equipment or control-document revision supporting this functional block.
- Check this application limit in the project design: Actual resource response can differ from the target.

## Important distinction

Actual resource response can differ from the target. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.

## Facts

- Representation: Functional block
- Installation focus: Microgrids
- Input / boundary: Requested power target
- Output / connection: Rate-limited target
- Lookup label: MARL is a library lookup label, not a standard device designation.

## Public references

- [Microgrid control systems](https://selinc.com/services/microgrids-power-management/microgrid-control-systems/) — SEL. Public technical context for microgrid active-power dispatch controls. Active and reactive power, generation, load control, operating reserves and system supervision. The application text and educational graphic are independently authored; the publisher does not certify this representation.

## Graphic scope

Independent original educational concept illustration by Elora Grid. Not a certified standards graphic or manufacturer footprint. Unitless; not to scale. Original artwork licence: https://creativecommons.org/licenses/by/4.0/. Publisher material is linked only.