{"schemaVersion":1,"slug":"microgrid-common-alarm-external-interface","name":"Microgrid common-alarm external interface","kind":"symbol","abbreviation":"MCEI","aliases":["Microgrid supervisory and communication interfaces","microgrids Microgrid supervisory and communication interfaces","microgrids","Microgrids","Assigned microgrid alarm group","External common-alarm output"],"category":"microgrid-systems","drawingTypes":["Schematic"],"referenceFamilies":["Manufacturer"],"summary":"Provides the defined alarm summary to an external supervisory system while preserving local detail.","description":["Provides the defined alarm summary to an external supervisory system while preserving local detail. Microgrid supervision coordinates measurements, control authority and resource communication without replacing local protection. Each resource value needs a named measurement boundary, freshness condition and intended control use.","In a microgrid control room, the operator can see source availability, active constraints and current operating mode. A communication failure should remain distinguishable from an electrical resource failure. For this reference, the drawing identifies “Assigned microgrid alarm group” at the input and “External common-alarm output” at the output. A summary alarm is not a diagnosis.","Identify signal ownership, quality flags, control priority and loss-of-data behavior. These functional references do not certify cyber security, closed-loop performance or equipment interoperability. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation."],"readingNotes":["Start at the named input: Assigned microgrid alarm group. Identify its source device or document and the state represented on the drawing.","Follow the named output: External common-alarm output. Cross-reference its destination and separate the command from confirmation that the equipment responded.","A summary alarm is not a diagnosis.","Identify signal ownership, quality flags, control priority and loss-of-data behavior. These functional references do not certify cyber security, closed-loop performance or equipment interoperability."],"drawingChecklist":["Label the source and connection reference for assigned microgrid alarm group.","Identify the destination and defined state of external common-alarm output.","Record the equipment or control-document revision supporting this functional block.","Check this application limit in the project design: A summary alarm is not a diagnosis."],"distinction":"A summary alarm is not a diagnosis. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.","facts":[{"label":"Representation","value":"Functional block"},{"label":"Installation focus","value":"Microgrids"},{"label":"Input / boundary","value":"Assigned microgrid alarm group"},{"label":"Output / connection","value":"External common-alarm output"},{"label":"Lookup label","value":"MCEI is a library lookup label, not a standard device designation."}],"references":[{"sourceId":"pi26-mg-power","relevance":"Public technical context for microgrid supervisory and communication interfaces. Active and reactive power, generation, load control, operating reserves and system supervision. The application text and educational graphic are independently authored; the publisher does not certify this representation."}],"related":["microgrid-controller","sequence-of-events-recorder","microgrid-resource-heartbeat-supervisor"],"artwork":"pi26-microgrid-common-alarm-external-interface","publishedOn":"2026-11-03","updatedOn":"2026-11-03","provenance":"independent-public-research","representation":{"type":"functional-block","focus":"microgrids","family":"microgrid-monitoring","input":"Assigned microgrid alarm group","output":"External common-alarm output"},"plainEnglish":{"title":"What this block does","introduction":"Provides the defined alarm summary to an external supervisory system while preserving local detail.","example":"In a microgrid control room, the operator can see source availability, active constraints and current operating mode. A communication failure should remain distinguishable from an electrical resource failure. For this reference, the drawing identifies “Assigned microgrid alarm group” at the input and “External common-alarm output” at the output. A summary alarm is not a diagnosis.","drawings":"Start at the named input: Assigned microgrid alarm group. Identify its source device or document and the state represented on the drawing. Follow the named output: External common-alarm output. Cross-reference its destination and separate the command from confirmation that the equipment responded.","terms":[{"name":"Input","meaning":"Assigned microgrid alarm group"},{"name":"Output","meaning":"External common-alarm output"},{"name":"Application reference","meaning":"An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections."}],"diagram":"flow","steps":["Assigned microgrid alarm group","MCEI","External common-alarm output"],"caption":"A reading guide. The entry's original illustration and input/output facts describe this application.","sources":[{"label":"Microgrid control systems","url":"https://selinc.com/services/microgrids-power-management/microgrid-control-systems/"}],"profileId":"power-installation-microgrid-monitoring"},"url":"https://eloragrid.ai/symbols/microgrid-common-alarm-external-interface","illustration":{"url":"https://eloragrid.ai/tools/electrical-library/illustrations/microgrid-common-alarm-external-interface.svg","scope":"Original educational concept; not an official standard graphic or product footprint","license":"https://creativecommons.org/licenses/by/4.0/"},"sources":[{"id":"pi26-mg-power","publisher":"SEL","title":"Microgrid control systems","url":"https://selinc.com/services/microgrids-power-management/microgrid-control-systems/","scope":"Active and reactive power, generation, load control, operating reserves and system supervision.","type":"manufacturer","checkedOn":"2026-11-03","reuse":"link-only","relevance":"Public technical context for microgrid supervisory and communication interfaces. Active and reactive power, generation, load control, operating reserves and system supervision. The application text and educational graphic are independently authored; the publisher does not certify this representation."}]}