{"schemaVersion":1,"slug":"microgrid-disturbance-recorder-trigger-interface","name":"Microgrid disturbance-recorder trigger interface","kind":"symbol","abbreviation":"MDTI","aliases":["Microgrid supervisory and communication interfaces","microgrids Microgrid supervisory and communication interfaces","microgrids","Microgrids","Defined operating disturbance","Recorder trigger"],"category":"microgrid-systems","drawingTypes":["Schematic"],"referenceFamilies":["Manufacturer"],"summary":"Maps the selected microgrid event to the assigned disturbance recording request.","description":["Maps the selected microgrid event to the assigned disturbance recording request. Microgrid supervision coordinates measurements, control authority and resource communication without replacing local protection. Each resource value needs a named measurement boundary, freshness condition and intended control use.","In a microgrid control room, the operator can see source availability, active constraints and current operating mode. A communication failure should remain distinguishable from an electrical resource failure. For this reference, the drawing identifies “Defined operating disturbance” at the input and “Recorder trigger” at the output. The recorded channels and trigger scope must be specified.","Identify signal ownership, quality flags, control priority and loss-of-data behavior. These functional references do not certify cyber security, closed-loop performance or equipment interoperability. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation."],"readingNotes":["Start at the named input: Defined operating disturbance. Identify its source device or document and the state represented on the drawing.","Follow the named output: Recorder trigger. Cross-reference its destination and separate the command from confirmation that the equipment responded.","The recorded channels and trigger scope must be specified.","Identify signal ownership, quality flags, control priority and loss-of-data behavior. These functional references do not certify cyber security, closed-loop performance or equipment interoperability."],"drawingChecklist":["Label the source and connection reference for defined operating disturbance.","Identify the destination and defined state of recorder trigger.","Record the equipment or control-document revision supporting this functional block.","Check this application limit in the project design: The recorded channels and trigger scope must be specified."],"distinction":"The recorded channels and trigger scope must be specified. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.","facts":[{"label":"Representation","value":"Functional block"},{"label":"Installation focus","value":"Microgrids"},{"label":"Input / boundary","value":"Defined operating disturbance"},{"label":"Output / connection","value":"Recorder trigger"},{"label":"Lookup label","value":"MDTI is a library lookup label, not a standard device designation."}],"references":[{"sourceId":"pi26-mg-power","relevance":"Public technical context for microgrid supervisory and communication interfaces. Active and reactive power, generation, load control, operating reserves and system supervision. The application text and educational graphic are independently authored; the publisher does not certify this representation."}],"related":["microgrid-controller","sequence-of-events-recorder","microgrid-control-mode-event-recorder"],"artwork":"pi26-microgrid-disturbance-recorder-trigger-interface","publishedOn":"2026-11-03","updatedOn":"2026-11-03","provenance":"independent-public-research","representation":{"type":"functional-block","focus":"microgrids","family":"microgrid-monitoring","input":"Defined operating disturbance","output":"Recorder trigger"},"plainEnglish":{"title":"What this block does","introduction":"Maps the selected microgrid event to the assigned disturbance recording request.","example":"In a microgrid control room, the operator can see source availability, active constraints and current operating mode. A communication failure should remain distinguishable from an electrical resource failure. For this reference, the drawing identifies “Defined operating disturbance” at the input and “Recorder trigger” at the output. The recorded channels and trigger scope must be specified.","drawings":"Start at the named input: Defined operating disturbance. Identify its source device or document and the state represented on the drawing. Follow the named output: Recorder trigger. Cross-reference its destination and separate the command from confirmation that the equipment responded.","terms":[{"name":"Input","meaning":"Defined operating disturbance"},{"name":"Output","meaning":"Recorder trigger"},{"name":"Application reference","meaning":"An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections."}],"diagram":"flow","steps":["Defined operating disturbance","MDTI","Recorder trigger"],"caption":"A reading guide. The entry's original illustration and input/output facts describe this application.","sources":[{"label":"Microgrid control systems","url":"https://selinc.com/services/microgrids-power-management/microgrid-control-systems/"}],"profileId":"power-installation-microgrid-monitoring"},"url":"https://eloragrid.ai/symbols/microgrid-disturbance-recorder-trigger-interface","illustration":{"url":"https://eloragrid.ai/tools/electrical-library/illustrations/microgrid-disturbance-recorder-trigger-interface.svg","scope":"Original educational concept; not an official standard graphic or product footprint","license":"https://creativecommons.org/licenses/by/4.0/"},"sources":[{"id":"pi26-mg-power","publisher":"SEL","title":"Microgrid control systems","url":"https://selinc.com/services/microgrids-power-management/microgrid-control-systems/","scope":"Active and reactive power, generation, load control, operating reserves and system supervision.","type":"manufacturer","checkedOn":"2026-11-03","reuse":"link-only","relevance":"Public technical context for microgrid supervisory and communication interfaces. Active and reactive power, generation, load control, operating reserves and system supervision. The application text and educational graphic are independently authored; the publisher does not certify this representation."}]}