{"schemaVersion":1,"slug":"microgrid-dynamic-compensator-reference-interface","name":"Microgrid dynamic-compensator reference interface","kind":"symbol","abbreviation":"MDRI","aliases":["Microgrid voltage and reactive-power controls","microgrids Microgrid voltage and reactive-power controls","microgrids","Microgrids","Authorized compensation target","Compensator reference"],"category":"microgrid-systems","drawingTypes":["Schematic"],"referenceFamilies":["Manufacturer"],"summary":"Sends the assigned reactive or voltage target to the selected compensator control system.","description":["Sends the assigned reactive or voltage target to the selected compensator control system. Voltage and reactive-power control coordinate the AC operating condition of the microgrid resources. A voltage target, reactive-power target and power-factor target represent different control objectives and should have explicit ownership.","In an islanded microgrid, the assigned reference source supports bus voltage while other compatible resources share reactive demand according to the selected control method. Grid-connected operation can use a different objective at the PCC. For this reference, the drawing identifies “Authorized compensation target” at the input and “Compensator reference” at the output. The compensator's accepted mode must be identified.","Show each measured quantity, target and resource capability limit. Control-loop tuning, equipment capability and parallel operation require a validated design rather than an assumed property of the symbol. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation."],"readingNotes":["Start at the named input: Authorized compensation target. Identify its source device or document and the state represented on the drawing.","Follow the named output: Compensator reference. Cross-reference its destination and separate the command from confirmation that the equipment responded.","The compensator's accepted mode must be identified.","Show each measured quantity, target and resource capability limit. Control-loop tuning, equipment capability and parallel operation require a validated design rather than an assumed property of the symbol."],"drawingChecklist":["Label the source and connection reference for authorized compensation target.","Identify the destination and defined state of compensator reference.","Record the equipment or control-document revision supporting this functional block.","Check this application limit in the project design: The compensator's accepted mode must be identified."],"distinction":"The compensator's accepted mode must be identified. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.","facts":[{"label":"Representation","value":"Functional block"},{"label":"Installation focus","value":"Microgrids"},{"label":"Input / boundary","value":"Authorized compensation target"},{"label":"Output / connection","value":"Compensator reference"},{"label":"Lookup label","value":"MDRI is a library lookup label, not a standard device designation."}],"references":[{"sourceId":"pi26-mg-power","relevance":"Public technical context for microgrid voltage and reactive-power controls. Active and reactive power, generation, load control, operating reserves and system supervision. The application text and educational graphic are independently authored; the publisher does not certify this representation."}],"related":["grid-forming-inverter","statcom","microgrid-voltage-control-saturation-alarm"],"artwork":"pi26-microgrid-dynamic-compensator-reference-interface","publishedOn":"2026-11-03","updatedOn":"2026-11-03","provenance":"independent-public-research","representation":{"type":"functional-block","focus":"microgrids","family":"microgrid-reactive","input":"Authorized compensation target","output":"Compensator reference"},"plainEnglish":{"title":"What this block does","introduction":"Sends the assigned reactive or voltage target to the selected compensator control system.","example":"In an islanded microgrid, the assigned reference source supports bus voltage while other compatible resources share reactive demand according to the selected control method. Grid-connected operation can use a different objective at the PCC. For this reference, the drawing identifies “Authorized compensation target” at the input and “Compensator reference” at the output. The compensator's accepted mode must be identified.","drawings":"Start at the named input: Authorized compensation target. Identify its source device or document and the state represented on the drawing. Follow the named output: Compensator reference. Cross-reference its destination and separate the command from confirmation that the equipment responded.","terms":[{"name":"Input","meaning":"Authorized compensation target"},{"name":"Output","meaning":"Compensator reference"},{"name":"Application reference","meaning":"An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections."}],"diagram":"flow","steps":["Authorized compensation target","MDRI","Compensator reference"],"caption":"A reading guide. The entry's original illustration and input/output facts describe this application.","sources":[{"label":"Microgrid control systems","url":"https://selinc.com/services/microgrids-power-management/microgrid-control-systems/"}],"profileId":"power-installation-microgrid-reactive"},"url":"https://eloragrid.ai/symbols/microgrid-dynamic-compensator-reference-interface","illustration":{"url":"https://eloragrid.ai/tools/electrical-library/illustrations/microgrid-dynamic-compensator-reference-interface.svg","scope":"Original educational concept; not an official standard graphic or product footprint","license":"https://creativecommons.org/licenses/by/4.0/"},"sources":[{"id":"pi26-mg-power","publisher":"SEL","title":"Microgrid control systems","url":"https://selinc.com/services/microgrids-power-management/microgrid-control-systems/","scope":"Active and reactive power, generation, load control, operating reserves and system supervision.","type":"manufacturer","checkedOn":"2026-11-03","reuse":"link-only","relevance":"Public technical context for microgrid voltage and reactive-power controls. Active and reactive power, generation, load control, operating reserves and system supervision. The application text and educational graphic are independently authored; the publisher does not certify this representation."}]}