# Microgrid generator operation-mode mismatch

Canonical URL: https://eloragrid.ai/symbols/microgrid-generator-operation-mode-mismatch
Publisher: Elora Grid
Updated: 2026-11-03
Lookup label: MGOM
Drawing use: Schematic
Reference families: Manufacturer

Representation: Functional block
Installation focus: microgrids
Input: Requested and reported generator modes
Output: Generator mode mismatch alarm

Detects disagreement between the requested generator control role and its reported mode.

## In plain English

### What this block does

Detects disagreement between the requested generator control role and its reported mode.

### A simple example

In a microgrid power station, the controller can request an additional generator when available reserve falls and later unload a selected machine before its documented stop sequence. For this reference, the drawing identifies “Requested and reported generator modes” at the input and “Generator mode mismatch alarm” at the output. A connected source may not accept every control mode.

### What the drawings help you do

Start at the named input: Requested and reported generator modes. Identify its source device or document and the state represented on the drawing. Follow the named output: Generator mode mismatch alarm. Cross-reference its destination and separate the command from confirmation that the equipment responded.

### Terms

- Input: Requested and reported generator modes
- Output: Generator mode mismatch alarm
- Application reference: An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections.

Concept diagram: Requested and reported generator modes → MGOM → Generator mode mismatch alarm
A reading guide. The entry's original illustration and input/output facts describe this application.

- [AGC power management options G4, G5 and G8](https://www.deif.com/media/5a4bx0xv/agc-3-option-g4-g5-and-g8-power-management-4189340696-uk.pdf)


## What it represents

Detects disagreement between the requested generator control role and its reported mode. Generating-set coordination decides which available machines should operate and how their power contribution is shared. Engine starting, breaker connection, load acceptance and stopping are separate stages with their own feedback.
In a microgrid power station, the controller can request an additional generator when available reserve falls and later unload a selected machine before its documented stop sequence. For this reference, the drawing identifies “Requested and reported generator modes” at the input and “Generator mode mismatch alarm” at the output. A connected source may not accept every control mode.
Preserve the engine and generator electrical boundaries, command authority and source readiness. Starting duty, minimum loading, synchronising, fuel systems and cooling behavior require the selected generator documentation. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation.

## How to read it

- Start at the named input: Requested and reported generator modes. Identify its source device or document and the state represented on the drawing.
- Follow the named output: Generator mode mismatch alarm. Cross-reference its destination and separate the command from confirmation that the equipment responded.
- A connected source may not accept every control mode.
- Preserve the engine and generator electrical boundaries, command authority and source readiness. Starting duty, minimum loading, synchronising, fuel systems and cooling behavior require the selected generator documentation.

## Information to show or reference

- Label the source and connection reference for requested and reported generator modes.
- Identify the destination and defined state of generator mode mismatch alarm.
- Record the equipment or control-document revision supporting this functional block.
- Check this application limit in the project design: A connected source may not accept every control mode.

## Important distinction

A connected source may not accept every control mode. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.

## Facts

- Representation: Functional block
- Installation focus: Microgrids
- Input / boundary: Requested and reported generator modes
- Output / connection: Generator mode mismatch alarm
- Lookup label: MGOM is a library lookup label, not a standard device designation.

## Public references

- [AGC power management options G4, G5 and G8](https://www.deif.com/media/5a4bx0xv/agc-3-option-g4-g5-and-g8-power-management-4189340696-uk.pdf) — DEIF. Public technical context for microgrid generating-set coordination. Generator start/stop, load sharing, reserve and power management. The application text and educational graphic are independently authored; the publisher does not certify this representation.