# Microgrid renewable-penetration supervisor

Canonical URL: https://eloragrid.ai/symbols/microgrid-renewable-penetration-supervisor
Publisher: Elora Grid
Updated: 2026-11-03
Lookup label: MRS
Drawing use: Schematic
Reference families: Manufacturer

Representation: Functional block
Installation focus: microgrids
Input: Renewable and total power quantities
Output: Renewable contribution information

Calculates the assigned renewable contribution measure used by the documented operating strategy.

## In plain English

### What this block does

Calculates the assigned renewable contribution measure used by the documented operating strategy.

### A simple example

In a microgrid with solar generation, the controller can restrain inverter output when local load and storage cannot absorb the available power. The resource controller reports its own availability and accepted operating limits. For this reference, the drawing identifies “Renewable and total power quantities” at the input and “Renewable contribution information” at the output. The chosen ratio and measurement boundary must be defined.

### What the drawings help you do

Start at the named input: Renewable and total power quantities. Identify its source device or document and the state represented on the drawing. Follow the named output: Renewable contribution information. Cross-reference its destination and separate the command from confirmation that the equipment responded.

### Terms

- Input: Renewable and total power quantities
- Output: Renewable contribution information
- Application reference: An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections.

Concept diagram: Renewable and total power quantities → MRS → Renewable contribution information
A reading guide. The entry's original illustration and input/output facts describe this application.

- [Microgrid processing and control functions](https://productinfo.se.com/esxp_digital_apps_iec/mg/English/BM_ESXP_DG_Microgrid_IEC_0001122076.xml/%24/ESXP_DG_MG_SD_Processing_0001125595)


## What it represents

Calculates the assigned renewable contribution measure used by the documented operating strategy. Renewable-generation coordination connects variable resource availability, inverter operating limits and the microgrid power target. Available solar or wind power, an issued curtailment request and actual delivered power are different signals.
In a microgrid with solar generation, the controller can restrain inverter output when local load and storage cannot absorb the available power. The resource controller reports its own availability and accepted operating limits. For this reference, the drawing identifies “Renewable and total power quantities” at the input and “Renewable contribution information” at the output. The chosen ratio and measurement boundary must be defined.
Identify the point where power is measured and the system declaring each availability or limit signal. Resource forecasts and controller requests do not guarantee the delivered generation at every instant. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation.

## How to read it

- Start at the named input: Renewable and total power quantities. Identify its source device or document and the state represented on the drawing.
- Follow the named output: Renewable contribution information. Cross-reference its destination and separate the command from confirmation that the equipment responded.
- The chosen ratio and measurement boundary must be defined.
- Identify the point where power is measured and the system declaring each availability or limit signal. Resource forecasts and controller requests do not guarantee the delivered generation at every instant.

## Information to show or reference

- Label the source and connection reference for renewable and total power quantities.
- Identify the destination and defined state of renewable contribution information.
- Record the equipment or control-document revision supporting this functional block.
- Check this application limit in the project design: The chosen ratio and measurement boundary must be defined.

## Important distinction

The chosen ratio and measurement boundary must be defined. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.

## Facts

- Representation: Functional block
- Installation focus: Microgrids
- Input / boundary: Renewable and total power quantities
- Output / connection: Renewable contribution information
- Lookup label: MRS is a library lookup label, not a standard device designation.

## Public references

- [Microgrid processing and control functions](https://productinfo.se.com/esxp_digital_apps_iec/mg/English/BM_ESXP_DG_Microgrid_IEC_0001122076.xml/%24/ESXP_DG_MG_SD_Processing_0001125595) — Schneider Electric. Public technical context for microgrid renewable-generation interfaces. Renewable generation dispatch and microgrid source coordination. The application text and educational graphic are independently authored; the publisher does not certify this representation.

## Graphic scope