# Microgrid resource command-acceptance feedback

Canonical URL: https://eloragrid.ai/symbols/microgrid-resource-command-acceptance-feedback
Publisher: Elora Grid
Updated: 2026-11-03
Lookup label: MRCF
Drawing use: Schematic
Reference families: Manufacturer

Representation: Functional block
Installation focus: microgrids
Input: Command acknowledgement
Output: Accepted or rejected target status

Receives the controller's declared acceptance or rejection of the assigned operating target.

## In plain English

### What this block does

Receives the controller's declared acceptance or rejection of the assigned operating target.

### A simple example

In a microgrid control room, the operator can see source availability, active constraints and current operating mode. A communication failure should remain distinguishable from an electrical resource failure. For this reference, the drawing identifies “Command acknowledgement” at the input and “Accepted or rejected target status” at the output. Acceptance differs from delivered physical response.

### What the drawings help you do

Start at the named input: Command acknowledgement. Identify its source device or document and the state represented on the drawing. Follow the named output: Accepted or rejected target status. Cross-reference its destination and separate the command from confirmation that the equipment responded.

### Terms

- Input: Command acknowledgement
- Output: Accepted or rejected target status
- Application reference: An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections.

Concept diagram: Command acknowledgement → MRCF → Accepted or rejected target status
A reading guide. The entry's original illustration and input/output facts describe this application.

- [Microgrid control systems](https://selinc.com/services/microgrids-power-management/microgrid-control-systems/)


## What it represents

Receives the controller's declared acceptance or rejection of the assigned operating target. Microgrid supervision coordinates measurements, control authority and resource communication without replacing local protection. Each resource value needs a named measurement boundary, freshness condition and intended control use.
In a microgrid control room, the operator can see source availability, active constraints and current operating mode. A communication failure should remain distinguishable from an electrical resource failure. For this reference, the drawing identifies “Command acknowledgement” at the input and “Accepted or rejected target status” at the output. Acceptance differs from delivered physical response.
Identify signal ownership, quality flags, control priority and loss-of-data behavior. These functional references do not certify cyber security, closed-loop performance or equipment interoperability. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation.

## How to read it

- Start at the named input: Command acknowledgement. Identify its source device or document and the state represented on the drawing.
- Follow the named output: Accepted or rejected target status. Cross-reference its destination and separate the command from confirmation that the equipment responded.
- Acceptance differs from delivered physical response.
- Identify signal ownership, quality flags, control priority and loss-of-data behavior. These functional references do not certify cyber security, closed-loop performance or equipment interoperability.

## Information to show or reference

- Label the source and connection reference for command acknowledgement.
- Identify the destination and defined state of accepted or rejected target status.
- Record the equipment or control-document revision supporting this functional block.
- Check this application limit in the project design: Acceptance differs from delivered physical response.

## Important distinction

Acceptance differs from delivered physical response. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.

## Facts

- Representation: Functional block
- Installation focus: Microgrids
- Input / boundary: Command acknowledgement
- Output / connection: Accepted or rejected target status
- Lookup label: MRCF is a library lookup label, not a standard device designation.

## Public references

- [Microgrid control systems](https://selinc.com/services/microgrids-power-management/microgrid-control-systems/) — SEL. Public technical context for microgrid supervisory and communication interfaces. Active and reactive power, generation, load control, operating reserves and system supervision. The application text and educational graphic are independently authored; the publisher does not certify this representation.

## Graphic scope

Independent original educational concept illustration by Elora Grid. Not a certified standards graphic or manufacturer footprint. Unitless; not to scale. Original artwork licence: https://creativecommons.org/licenses/by/4.0/. Publisher material is linked only.