{"schemaVersion":1,"slug":"microgrid-storage-communications-stale-gate","name":"Microgrid storage communications-stale gate","kind":"symbol","abbreviation":"MSCG","aliases":["Microgrid storage coordination interfaces","microgrids Microgrid storage coordination interfaces","microgrids","Microgrids","Storage data age and health","Storage-data validity state"],"category":"microgrid-systems","drawingTypes":["Schematic"],"referenceFamilies":["Manufacturer"],"summary":"Restrains use of storage limits or states that exceed their defined freshness condition.","description":["Restrains use of storage limits or states that exceed their defined freshness condition. Storage coordination combines the battery's energy limits with the converter's electrical capability and the microgrid's operating demand. State of charge, allowable power and connection status describe different aspects of availability.","In a microgrid with a battery energy storage system, the controller can request discharge to support a power deficit while the battery management and conversion systems enforce their own operating limits. For this reference, the drawing identifies “Storage data age and health” at the input and “Storage-data validity state” at the output. Fallback behavior must be specified.","Show which system declares each limit and which controller receives the target. Battery protection, converter capability, thermal management and emergency responses remain with the selected system design. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation."],"readingNotes":["Start at the named input: Storage data age and health. Identify its source device or document and the state represented on the drawing.","Follow the named output: Storage-data validity state. Cross-reference its destination and separate the command from confirmation that the equipment responded.","Fallback behavior must be specified.","Show which system declares each limit and which controller receives the target. Battery protection, converter capability, thermal management and emergency responses remain with the selected system design."],"drawingChecklist":["Label the source and connection reference for storage data age and health.","Identify the destination and defined state of storage-data validity state.","Record the equipment or control-document revision supporting this functional block.","Check this application limit in the project design: Fallback behavior must be specified."],"distinction":"Fallback behavior must be specified. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.","facts":[{"label":"Representation","value":"Functional block"},{"label":"Installation focus","value":"Microgrids"},{"label":"Input / boundary","value":"Storage data age and health"},{"label":"Output / connection","value":"Storage-data validity state"},{"label":"Lookup label","value":"MSCG is a library lookup label, not a standard device designation."}],"references":[{"sourceId":"pi26-mg-study","relevance":"Public technical context for microgrid storage coordination interfaces. Storage, protection, black start, load restoration and coordinated island operation. The application text and educational graphic are independently authored; the publisher does not certify this representation."}],"related":["battery-energy-storage-system","battery-power-conversion-system","microgrid-storage-charge-power-limit-interface"],"artwork":"pi26-microgrid-storage-communications-stale-gate","publishedOn":"2026-11-03","updatedOn":"2026-11-03","provenance":"independent-public-research","representation":{"type":"functional-block","focus":"microgrids","family":"microgrid-storage","input":"Storage data age and health","output":"Storage-data validity state"},"plainEnglish":{"title":"What this block does","introduction":"Restrains use of storage limits or states that exceed their defined freshness condition.","example":"In a microgrid with a battery energy storage system, the controller can request discharge to support a power deficit while the battery management and conversion systems enforce their own operating limits. For this reference, the drawing identifies “Storage data age and health” at the input and “Storage-data validity state” at the output. Fallback behavior must be specified.","drawings":"Start at the named input: Storage data age and health. Identify its source device or document and the state represented on the drawing. Follow the named output: Storage-data validity state. Cross-reference its destination and separate the command from confirmation that the equipment responded.","terms":[{"name":"Input","meaning":"Storage data age and health"},{"name":"Output","meaning":"Storage-data validity state"},{"name":"Application reference","meaning":"An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections."}],"diagram":"flow","steps":["Storage data age and health","MSCG","Storage-data validity state"],"caption":"A reading guide. The entry's original illustration and input/output facts describe this application.","sources":[{"label":"Avista Shared Energy Economy microgrid protection and control case study","url":"https://selinc.com/api/download/135486/"}],"profileId":"power-installation-microgrid-storage"},"url":"https://eloragrid.ai/symbols/microgrid-storage-communications-stale-gate","illustration":{"url":"https://eloragrid.ai/tools/electrical-library/illustrations/microgrid-storage-communications-stale-gate.svg","scope":"Original educational concept; not an official standard graphic or product footprint","license":"https://creativecommons.org/licenses/by/4.0/"},"sources":[{"id":"pi26-mg-study","publisher":"SEL","title":"Avista Shared Energy Economy microgrid protection and control case study","url":"https://selinc.com/api/download/135486/","scope":"Storage, protection, black start, load restoration and coordinated island operation.","type":"manufacturer","checkedOn":"2026-11-03","reuse":"link-only","relevance":"Public technical context for microgrid storage coordination interfaces. Storage, protection, black start, load restoration and coordinated island operation. The application text and educational graphic are independently authored; the publisher does not certify this representation."}]}