# Microgrid voltage-match adjustment output

Canonical URL: https://eloragrid.ai/symbols/microgrid-voltage-match-adjustment-output
Publisher: Elora Grid
Updated: 2026-11-03
Lookup label: MVAO
Drawing use: Schematic
Reference families: Manufacturer

Representation: Functional block
Installation focus: microgrids
Input: Voltage matching demand
Output: Source voltage adjustment

Requests the assigned source-voltage adjustment used by the reconnection control.

## In plain English

### What this block does

Requests the assigned source-voltage adjustment used by the reconnection control.

### A simple example

In a microgrid reconnecting at its point of common coupling, a synchroniser can adjust the island reference while a separate permissive confirms the permitted relationship across the open breaker. For this reference, the drawing identifies “Voltage matching demand” at the input and “Source voltage adjustment” at the output. Other voltage-control loops require coordination.

### What the drawings help you do

Start at the named input: Voltage matching demand. Identify its source device or document and the state represented on the drawing. Follow the named output: Source voltage adjustment. Cross-reference its destination and separate the command from confirmation that the equipment responded.

### Terms

- Input: Voltage matching demand
- Output: Source voltage adjustment
- Application reference: An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections.

Concept diagram: Voltage matching demand → MVAO → Source voltage adjustment
A reading guide. The entry's original illustration and input/output facts describe this application.

- [Microgrid Flex components and control design](https://productinfo.se.com/microgrid_guide/0100db2503_ecostruxure-microgrid-flex_design-guide_iec/English/0100DB2503-Microgrid%20Flex%20Design%20Guide-IEC-Optimize%20%28bookmap%29_DD00654397.XML.xml/%24/MicrogridFlexComponents-3A7DD96C)


## What it represents

Requests the assigned source-voltage adjustment used by the reconnection control. Synchronising control compares two AC systems before their assigned connecting breaker closes. Voltage magnitude, frequency, phase relationship, breaker readiness and command authority are separate inputs to the closing decision.
In a microgrid reconnecting at its point of common coupling, a synchroniser can adjust the island reference while a separate permissive confirms the permitted relationship across the open breaker. For this reference, the drawing identifies “Voltage matching demand” at the input and “Source voltage adjustment” at the output. Other voltage-control loops require coordination.
Identify the two measurement sides and the equipment receiving any adjustment request. Closing limits, breaker timing and loss-of-measurement behavior require the approved synchronising design. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation.

## How to read it

- Start at the named input: Voltage matching demand. Identify its source device or document and the state represented on the drawing.
- Follow the named output: Source voltage adjustment. Cross-reference its destination and separate the command from confirmation that the equipment responded.
- Other voltage-control loops require coordination.
- Identify the two measurement sides and the equipment receiving any adjustment request. Closing limits, breaker timing and loss-of-measurement behavior require the approved synchronising design.

## Information to show or reference

- Label the source and connection reference for voltage matching demand.
- Identify the destination and defined state of source voltage adjustment.
- Record the equipment or control-document revision supporting this functional block.
- Check this application limit in the project design: Other voltage-control loops require coordination.

## Important distinction

Other voltage-control loops require coordination. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.

## Facts

- Representation: Functional block
- Installation focus: Microgrids
- Input / boundary: Voltage matching demand
- Output / connection: Source voltage adjustment
- Lookup label: MVAO is a library lookup label, not a standard device designation.

## Public references

- [Microgrid Flex components and control design](https://productinfo.se.com/microgrid_guide/0100db2503_ecostruxure-microgrid-flex_design-guide_iec/English/0100DB2503-Microgrid%20Flex%20Design%20Guide-IEC-Optimize%20%28bookmap%29_DD00654397.XML.xml/%24/MicrogridFlexComponents-3A7DD96C) — Schneider Electric. Public technical context for microgrid synchronising interfaces. Microgrid power and control interfaces, synchronisation and source coordination. The application text and educational graphic are independently authored; the publisher does not certify this representation.

## Graphic scope

Independent original educational concept illustration by Elora Grid. Not a certified standards graphic or manufacturer footprint. Unitless; not to scale. Original artwork licence: https://creativecommons.org/licenses/by/4.0/. Publisher material is linked only.