# Motor run-feedback discrepancy

Canonical URL: https://eloragrid.ai/symbols/motor-run-feedback-discrepancy
Publisher: Elora Grid
Updated: 2026-11-03
Lookup label: MRD
Drawing use: Schematic
Reference families: Manufacturer

Representation: Functional block
Installation focus: switchgear
Input: Run command and feedback
Output: Run mismatch alarm

Detects disagreement between the requested motor run state and its defined feedback.

## In plain English

### What this block does

Detects disagreement between the requested motor run state and its defined feedback.

### A simple example

In a switchroom motor-control panel, a ventilation motor can receive an automatic start request while a local selector and the motor protection determine whether the feeder is available. For this reference, the drawing identifies “Run command and feedback” at the input and “Run mismatch alarm” at the output. Feedback may come from contactor or process sensing.

### What the drawings help you do

Start at the named input: Run command and feedback. Identify its source device or document and the state represented on the drawing. Follow the named output: Run mismatch alarm. Cross-reference its destination and separate the command from confirmation that the equipment responded.

### Terms

- Input: Run command and feedback
- Output: Run mismatch alarm
- Application reference: An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections.

Concept diagram: Run command and feedback → MRD → Run mismatch alarm
A reading guide. The entry's original illustration and input/output facts describe this application.

- [SEL-710 motor protection and control](https://selinc.com/products/710/)


## What it represents

Detects disagreement between the requested motor run state and its defined feedback. A motor feeder combines switching, motor protection and an operating command. Starting permission, running feedback and protection trip are different signals even where one relay or controller processes all of them.
In a switchroom motor-control panel, a ventilation motor can receive an automatic start request while a local selector and the motor protection determine whether the feeder is available. For this reference, the drawing identifies “Run command and feedback” at the input and “Run mismatch alarm” at the output. Feedback may come from contactor or process sensing.
Link the motor tag to its contactor, protective device and process permissives. The control diagram must identify stop priority, feedback and restart philosophy without supplying unverified settings. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation.

## How to read it

- Start at the named input: Run command and feedback. Identify its source device or document and the state represented on the drawing.
- Follow the named output: Run mismatch alarm. Cross-reference its destination and separate the command from confirmation that the equipment responded.
- Feedback may come from contactor or process sensing.
- Link the motor tag to its contactor, protective device and process permissives. The control diagram must identify stop priority, feedback and restart philosophy without supplying unverified settings.

## Information to show or reference

- Label the source and connection reference for run command and feedback.
- Identify the destination and defined state of run mismatch alarm.
- Record the equipment or control-document revision supporting this functional block.
- Check this application limit in the project design: Feedback may come from contactor or process sensing.

## Important distinction

Feedback may come from contactor or process sensing. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.

## Facts

- Representation: Functional block
- Installation focus: Switchgear
- Input / boundary: Run command and feedback
- Output / connection: Run mismatch alarm
- Lookup label: MRD is a library lookup label, not a standard device designation.

## Public references

- [SEL-710 motor protection and control](https://selinc.com/products/710/) — SEL. Public technical context for motor-feeder control interfaces. Motor feeder thermal, starting and control functions. The application text and educational graphic are independently authored; the publisher does not certify this representation.

## Graphic scope