# Pole-operated mechanism discrepancy

Canonical URL: https://eloragrid.ai/symbols/pole-operated-mechanism-discrepancy
Publisher: Elora Grid
Updated: 2026-11-03
Lookup label: PMD
Drawing use: Schematic
Reference families: Manufacturer

Representation: Functional block
Installation focus: switchgear
Input: Individual pole states
Output: Pole discrepancy indication

Compares pole-operation feedback where the selected breaker has independently monitored poles.

## In plain English

### What this block does

Compares pole-operation feedback where the selected breaker has independently monitored poles.

### A simple example

In a switchgear panel, a charging motor replenishes the mechanism after an operation. Supervisory contacts let the controller report an incomplete charge or repeated charging demand before an operator requests another operation. For this reference, the drawing identifies “Individual pole states” at the input and “Pole discrepancy indication” at the output. A three-phase device can have different mechanism arrangements.

### What the drawings help you do

Start at the named input: Individual pole states. Identify its source device or document and the state represented on the drawing. Follow the named output: Pole discrepancy indication. Cross-reference its destination and separate the command from confirmation that the equipment responded.

### Terms

- Input: Individual pole states
- Output: Pole discrepancy indication
- Application reference: An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections.

Concept diagram: Individual pole states → PMD → Pole discrepancy indication
A reading guide. The entry's original illustration and input/output facts describe this application.

- [Masterclad medium-voltage switchgear: circuit-breaker section interlocks](https://productinfo.se.com/masterclad_mv_switchgear_ib/6055-30-masterclad-15kv-mv-switchgear-ib/English/6055-30%20Masterclad%20MV%20Switchgear%20Indoor%20%28bookmap%29_DD00646805.xml/%24/Section6-CircuitBreakerSectionInter-58DD6EC7)


## What it represents

Compares pole-operation feedback where the selected breaker has independently monitored poles. A stored-energy breaker mechanism has charging, release, indication and supervision functions. Motor supply, stored spring energy and the ability to complete an opening operation are separate drawing concerns.
In a switchgear panel, a charging motor replenishes the mechanism after an operation. Supervisory contacts let the controller report an incomplete charge or repeated charging demand before an operator requests another operation. For this reference, the drawing identifies “Individual pole states” at the input and “Pole discrepancy indication” at the output. A three-phase device can have different mechanism arrangements.
Show the individual contacts and the relevant motor or release circuit. Supply voltage, charging time, operating duty and permissible alarms must follow the chosen mechanism documentation. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation.

## How to read it

- Start at the named input: Individual pole states. Identify its source device or document and the state represented on the drawing.
- Follow the named output: Pole discrepancy indication. Cross-reference its destination and separate the command from confirmation that the equipment responded.
- A three-phase device can have different mechanism arrangements.
- Show the individual contacts and the relevant motor or release circuit. Supply voltage, charging time, operating duty and permissible alarms must follow the chosen mechanism documentation.

## Information to show or reference

- Label the source and connection reference for individual pole states.
- Identify the destination and defined state of pole discrepancy indication.
- Record the equipment or control-document revision supporting this functional block.
- Check this application limit in the project design: A three-phase device can have different mechanism arrangements.

## Important distinction

A three-phase device can have different mechanism arrangements. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.

## Facts

- Representation: Functional block
- Installation focus: Switchgear
- Input / boundary: Individual pole states
- Output / connection: Pole discrepancy indication
- Lookup label: PMD is a library lookup label, not a standard device designation.

## Public references

- [Masterclad medium-voltage switchgear: circuit-breaker section interlocks](https://productinfo.se.com/masterclad_mv_switchgear_ib/6055-30-masterclad-15kv-mv-switchgear-ib/English/6055-30%20Masterclad%20MV%20Switchgear%20Indoor%20%28bookmap%29_DD00646805.xml/%24/Section6-CircuitBreakerSectionInter-58DD6EC7) — Schneider Electric. Public technical context for stored-energy mechanism supervision. Breaker control, mechanism, position contacts, racking interlocks and test interfaces. The application text and educational graphic are independently authored; the publisher does not certify this representation.

## Graphic scope

Independent original educational concept illustration by Elora Grid. Not a certified standards graphic or manufacturer footprint. Unitless; not to scale. Original artwork licence: https://creativecommons.org/licenses/by/4.0/. Publisher material is linked only.