{"schemaVersion":1,"slug":"post-glover-neutral-grounding-resistor-enclosure-outline","name":"Post Glover neutral grounding resistor enclosure","kind":"object","abbreviation":"NGR enclosure","aliases":["Post Glover neutral grounding resistor enclosure GA","NGR enclosure layout","NGR enclosure CAD","NGR enclosure general arrangement"],"category":"equipment-layouts","drawingTypes":["GA"],"referenceFamilies":["Manufacturer"],"summary":"Neutral grounding resistor enclosure placement and connection-zone coordination.","description":["Locate the resistor enclosure relative to the transformer neutral connection and earthing route. Preserve access to termination points and the selected ventilation faces.","Use the linked manufacturer drawing or project mechanical files for dimensions and the exact selected revision. This original educational illustration is unitless and not to scale."],"readingNotes":["Show neutral and earth connection routes.","The source is a typical PDF outline, not a native CAD model or proof of the final resistor rating and duty."],"drawingChecklist":["Request the project-specific enclosure drawing.","Show neutral and earth connection routes.","Confirm heat-clearance, fixing and inspection access."],"distinction":"The source is a typical PDF outline, not a native CAD model or proof of the final resistor rating and duty.","facts":[{"label":"Manufacturer or project publisher","value":"Post Glover"},{"label":"Family or order code","value":"NGR enclosure"},{"label":"CAD relationship","value":"Same reviewed source and configuration scope; select the matching original"},{"label":"Illustration","value":"Original conceptual GA; no dimensional or certification claim"}],"references":[{"sourceId":"ga-scale-post-glover-neutral-grounding-resistor-enclosure-outline","relevance":"Official identity and available drawing scope; coordination guidance is independently written."}],"related":["ga-neutral-earthing-resistor-cabinet","transformer-envelope"],"artwork":"edu-object-post-glover-neutral-grounding-resistor-enclosure-outline","publishedOn":"2026-10-29","updatedOn":"2026-10-29","provenance":"independent-public-research","plainEnglish":{"title":"What it does","introduction":"A neutral earthing resistor limits current in the designed connection between a system's neutral and earth during an earth fault.","example":"In a microgrid substation, the resistor can limit earth-fault current on the selected generator or transformer neutral connection.","drawings":"Use the selected manufacturer's drawings to check the equipment's size, mounting points and cable connections. The layout helps you plan where it fits and how it can be reached for maintenance. An illustrative 3D preview does not establish product dimensions or required clearances.","terms":[{"name":"Current","meaning":"The flow of electrical charge, measured in amps."},{"name":"Terminal","meaning":"An identified point where a conductor connects."},{"name":"Rating","meaning":"A value stating the conditions for which equipment is specified."}],"diagram":"flow","steps":["System neutral","Earthing resistor","Earth network"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Post Glover neutral grounding resistor enclosure: official source","url":"https://www.postglover.com/literature-library/"}],"profileId":"neutral-resistor"},"url":"https://eloragrid.ai/objects/post-glover-neutral-grounding-resistor-enclosure-outline","illustration":{"url":"https://eloragrid.ai/tools/electrical-library/equipment-preview/post-glover-neutral-grounding-resistor-enclosure-outline","scope":"Equipment preview: manufacturer drawing where available, otherwise a 3D thumbnail. Original object icon exports are removed."},"drawings":[],"sources":[{"id":"ga-scale-post-glover-neutral-grounding-resistor-enclosure-outline","title":"Post Glover neutral grounding resistor enclosure: official source","publisher":"Post Glover","url":"https://www.postglover.com/literature-library/","type":"manufacturer","scope":"Equipment or project identity and drawing route; no copied manufacturer artwork.","checkedOn":"2026-10-29","reuse":"link-only","relevance":"Official identity and available drawing scope; coordination guidance is independently written."}]}