# PTP grandmaster timing interface

Canonical URL: https://eloragrid.ai/symbols/ptp-grandmaster-timing-interface
Publisher: Elora Grid
Updated: 2026-11-03
Lookup label: PGTI
Drawing use: Schematic
Reference families: Manufacturer

Representation: Functional block
Installation focus: substations
Input: Station time source
Output: PTP timing messages

Identifies the clock distributing the selected precision-time reference to its network clients.

## In plain English

### What this block does

Identifies the clock distributing the selected precision-time reference to its network clients.

### A simple example

In a substation, a station clock can provide precision timing to process equipment and another timing interface to event recorders. The alarm system should distinguish loss of a distribution path from loss of the external time source. For this reference, the drawing identifies “Station time source” at the input and “PTP timing messages” at the output. The required profile must be identified.

### What the drawings help you do

Start at the named input: Station time source. Identify its source device or document and the state represented on the drawing. Follow the named output: PTP timing messages. Cross-reference its destination and separate the command from confirmation that the equipment responded.

### Terms

- Input: Station time source
- Output: PTP timing messages
- Application reference: An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections.

Concept diagram: Station time source → PGTI → PTP timing messages
A reading guide. The entry's original illustration and input/output facts describe this application.

- [SEL-2488 satellite-synchronised network clock](https://selinc.com/products/2488/)


## What it represents

Identifies the clock distributing the selected precision-time reference to its network clients. A station time system provides a shared time reference for protection records, measurements and automation. Different devices can use different timing protocols, so the time source, distribution path and quality information must remain identifiable.
In a substation, a station clock can provide precision timing to process equipment and another timing interface to event recorders. The alarm system should distinguish loss of a distribution path from loss of the external time source. For this reference, the drawing identifies “Station time source” at the input and “PTP timing messages” at the output. The required profile must be identified.
Show the source and client of each time connection. Required accuracy, holdover, protocol profile and loss-of-time behavior follow the selected application; a common timestamp format does not guarantee synchronized events. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation.

## How to read it

- Start at the named input: Station time source. Identify its source device or document and the state represented on the drawing.
- Follow the named output: PTP timing messages. Cross-reference its destination and separate the command from confirmation that the equipment responded.
- The required profile must be identified.
- Show the source and client of each time connection. Required accuracy, holdover, protocol profile and loss-of-time behavior follow the selected application; a common timestamp format does not guarantee synchronized events.

## Information to show or reference

- Label the source and connection reference for station time source.
- Identify the destination and defined state of ptp timing messages.
- Record the equipment or control-document revision supporting this functional block.
- Check this application limit in the project design: The required profile must be identified.

## Important distinction

The required profile must be identified. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.

## Facts

- Representation: Functional block
- Installation focus: Substations
- Input / boundary: Station time source
- Output / connection: PTP timing messages
- Lookup label: PGTI is a library lookup label, not a standard device designation.

## Public references

- [SEL-2488 satellite-synchronised network clock](https://selinc.com/products/2488/) — SEL. Public technical context for substation timing and event interfaces. PTP, NTP, IRIG-B, pulse distribution, reference failover and timing quality. The application text and educational graphic are independently authored; the publisher does not certify this representation.

## Graphic scope

Independent original educational concept illustration by Elora Grid. Not a certified standards graphic or manufacturer footprint. Unitless; not to scale. Original artwork licence: https://creativecommons.org/licenses/by/4.0/. Publisher material is linked only.