{"schemaVersion":1,"slug":"remote-control-communications-loss-inhibit","name":"Remote-control communications-loss inhibit","kind":"symbol","abbreviation":"RCI","aliases":["Substation automation and command interfaces","substations Substation automation and command interfaces","substations","Substations","Link health and authority","Remote-operation restraint"],"category":"measurement-protection","drawingTypes":["Schematic"],"referenceFamilies":["Manufacturer"],"summary":"Applies the documented restraint to remote operating requests when their required communication path is lost.","description":["Applies the documented restraint to remote operating requests when their required communication path is lost. Station automation collects measurements and statuses and issues assigned commands through defined authority paths. A communicated point has a value, quality and equipment identity; it should not be treated as an unexplained contact.","In a substation control building, the station controller receives bay information and forwards an operator's selected command to the correct bay device. Device feedback confirms whether the intended result actually occurred. For this reference, the drawing identifies “Link health and authority” at the input and “Remote-operation restraint” at the output. Local protection must retain its defined independence.","Document the point mapping, source, destination, command authority and failure behavior. A communication interface block explains information flow and does not certify network security or control-system availability. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation."],"readingNotes":["Start at the named input: Link health and authority. Identify its source device or document and the state represented on the drawing.","Follow the named output: Remote-operation restraint. Cross-reference its destination and separate the command from confirmation that the equipment responded.","Local protection must retain its defined independence.","Document the point mapping, source, destination, command authority and failure behavior. A communication interface block explains information flow and does not certify network security or control-system availability."],"drawingChecklist":["Label the source and connection reference for link health and authority.","Identify the destination and defined state of remote-operation restraint.","Record the equipment or control-document revision supporting this functional block.","Check this application limit in the project design: Local protection must retain its defined independence."],"distinction":"Local protection must retain its defined independence. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.","facts":[{"label":"Representation","value":"Functional block"},{"label":"Installation focus","value":"Substations"},{"label":"Input / boundary","value":"Link health and authority"},{"label":"Output / connection","value":"Remote-operation restraint"},{"label":"Lookup label","value":"RCI is a library lookup label, not a standard device designation."}],"references":[{"sourceId":"pi26-station-automation","relevance":"Public technical context for substation automation and command interfaces. Station I/O, alarms, event recording, command and communications interfaces. The application text and educational graphic are independently authored; the publisher does not certify this representation."}],"related":["ga-substation-rtu","plc-digital-input","station-local-control-ownership-interface"],"artwork":"pi26-remote-control-communications-loss-inhibit","publishedOn":"2026-11-03","updatedOn":"2026-11-03","provenance":"independent-public-research","representation":{"type":"functional-block","focus":"substations","family":"station-automation","input":"Link health and authority","output":"Remote-operation restraint"},"plainEnglish":{"title":"What this block does","introduction":"Applies the documented restraint to remote operating requests when their required communication path is lost.","example":"In a substation control building, the station controller receives bay information and forwards an operator's selected command to the correct bay device. Device feedback confirms whether the intended result actually occurred. For this reference, the drawing identifies “Link health and authority” at the input and “Remote-operation restraint” at the output. Local protection must retain its defined independence.","drawings":"Start at the named input: Link health and authority. Identify its source device or document and the state represented on the drawing. Follow the named output: Remote-operation restraint. Cross-reference its destination and separate the command from confirmation that the equipment responded.","terms":[{"name":"Input","meaning":"Link health and authority"},{"name":"Output","meaning":"Remote-operation restraint"},{"name":"Application reference","meaning":"An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections."}],"diagram":"flow","steps":["Link health and authority","RCI","Remote-operation restraint"],"caption":"A reading guide. The entry's original illustration and input/output facts describe this application.","sources":[{"label":"SEL-2411 programmable automation controller","url":"https://selinc.com/products/2411/"}],"profileId":"power-installation-station-automation"},"url":"https://eloragrid.ai/symbols/remote-control-communications-loss-inhibit","illustration":{"url":"https://eloragrid.ai/tools/electrical-library/illustrations/remote-control-communications-loss-inhibit.svg","scope":"Original educational concept; not an official standard graphic or product footprint","license":"https://creativecommons.org/licenses/by/4.0/"},"sources":[{"id":"pi26-station-automation","publisher":"SEL","title":"SEL-2411 programmable automation controller","url":"https://selinc.com/products/2411/","scope":"Station I/O, alarms, event recording, command and communications interfaces.","type":"manufacturer","checkedOn":"2026-11-03","reuse":"link-only","relevance":"Public technical context for substation automation and command interfaces. Station I/O, alarms, event recording, command and communications interfaces. The application text and educational graphic are independently authored; the publisher does not certify this representation."}]}