Reports that the charging motor is operating rather than merely commanded.

## In plain English

### What this block does

Reports that the charging motor is operating rather than merely commanded.

### A simple example

In a switchgear panel, a charging motor replenishes the mechanism after an operation. Supervisory contacts let the controller report an incomplete charge or repeated charging demand before an operator requests another operation. For this reference, the drawing identifies “Motor running feedback” at the input and “Charging-running indication” at the output. A run command does not prove rotation.

### What the drawings help you do

Start at the named input: Motor running feedback. Identify its source device or document and the state represented on the drawing. Follow the named output: Charging-running indication. Cross-reference its destination and separate the command from confirmation that the equipment responded.

### Terms

- Input: Motor running feedback
- Output: Charging-running indication
- Application reference: An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections.

Concept diagram: Motor running feedback → SMRC → Charging-running indication
A reading guide. The entry's original illustration and input/output facts describe this application.

- [Masterclad medium-voltage switchgear: circuit-breaker section interlocks](https://productinfo.se.com/masterclad_mv_switchgear_ib/6055-30-masterclad-15kv-mv-switchgear-ib/English/6055-30%20Masterclad%20MV%20Switchgear%20Indoor%20%28bookmap%29_DD00646805.xml/%24/Section6-CircuitBreakerSectionInter-58DD6EC7)


## What it represents

Reports that the charging motor is operating rather than merely commanded. A stored-energy breaker mechanism has charging, release, indication and supervision functions. Motor supply, stored spring energy and the ability to complete an opening operation are separate drawing concerns.
In a switchgear panel, a charging motor replenishes the mechanism after an operation. Supervisory contacts let the controller report an incomplete charge or repeated charging demand before an operator requests another operation. For this reference, the drawing identifies “Motor running feedback” at the input and “Charging-running indication” at the output. A run command does not prove rotation.
Show the individual contacts and the relevant motor or release circuit. Supply voltage, charging time, operating duty and permissible alarms must follow the chosen mechanism documentation. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation.

## How to read it

- Start at the named input: Motor running feedback. Identify its source device or document and the state represented on the drawing.
- Follow the named output: Charging-running indication. Cross-reference its destination and separate the command from confirmation that the equipment responded.
- A run command does not prove rotation.
- Show the individual contacts and the relevant motor or release circuit. Supply voltage, charging time, operating duty and permissible alarms must follow the chosen mechanism documentation.

## Information to show or reference

- Label the source and connection reference for motor running feedback.
- Identify the destination and defined state of charging-running indication.
- Record the equipment or control-document revision supporting this functional block.
- Check this application limit in the project design: A run command does not prove rotation.

## Important distinction

A run command does not prove rotation. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.

## Facts

- Representation: Functional block
- Installation focus: Switchgear
- Input / boundary: Motor running feedback
- Output / connection: Charging-running indication
- Lookup label: SMRC is a library lookup label, not a standard device designation.

## Public references

- [Masterclad medium-voltage switchgear: circuit-breaker section interlocks](https://productinfo.se.com/masterclad_mv_switchgear_ib/6055-30-masterclad-15kv-mv-switchgear-ib/English/6055-30%20Masterclad%20MV%20Switchgear%20Indoor%20%28bookmap%29_DD00646805.xml/%24/Section6-CircuitBreakerSectionInter-58DD6EC7) — Schneider Electric. Public technical context for stored-energy mechanism supervision. Breaker control, mechanism, position contacts, racking interlocks and test interfaces. The application text and educational graphic are independently authored; the publisher does not certify this representation.