# Switchroom cooling-available indication

Canonical URL: https://eloragrid.ai/symbols/switchroom-cooling-available-indication
Publisher: Elora Grid
Updated: 2026-11-03
Lookup label: SCI
Drawing use: Schematic
Reference families: Manufacturer

Representation: Functional block
Installation focus: switchrooms
Input: Cooling equipment health
Output: Cooling available status

Reports the documented availability of the assigned room-cooling equipment.

## In plain English

### What this block does

Reports the documented availability of the assigned room-cooling equipment.

### A simple example

In a switchroom containing transformers and auxiliary panels, the room controller can supervise fan availability and send an alarm when the documented ventilation duty is not achieved. For this reference, the drawing identifies “Cooling equipment health” at the input and “Cooling available status” at the output. Availability is different from thermal capacity.

### What the drawings help you do

Start at the named input: Cooling equipment health. Identify its source device or document and the state represented on the drawing. Follow the named output: Cooling available status. Cross-reference its destination and separate the command from confirmation that the equipment responded.

### Terms

- Input: Cooling equipment health
- Output: Cooling available status
- Application reference: An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections.

Concept diagram: Cooling equipment health → SCI → Cooling available status
A reading guide. The entry's original illustration and input/output facts describe this application.

- [Ventilation in MV substations](https://www.electrical-installation.org/enwiki/Ventilation_in_MV_Substations)


## What it represents

Reports the documented availability of the assigned room-cooling equipment. Ventilation control coordinates the equipment that manages heat and air movement in an electrical room. A temperature request, a fan command and proof of airflow are separate signals, and the room design determines how they interact.
In a switchroom containing transformers and auxiliary panels, the room controller can supervise fan availability and send an alarm when the documented ventilation duty is not achieved. For this reference, the drawing identifies “Cooling equipment health” at the input and “Cooling available status” at the output. Availability is different from thermal capacity.
Identify the monitored space, the selected ventilation mode and the equipment feedback. Avoid inferring airflow, temperature limits or a fire response from a generic fan symbol; these require the room-services design. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation.

## How to read it

- Start at the named input: Cooling equipment health. Identify its source device or document and the state represented on the drawing.
- Follow the named output: Cooling available status. Cross-reference its destination and separate the command from confirmation that the equipment responded.
- Availability is different from thermal capacity.
- Identify the monitored space, the selected ventilation mode and the equipment feedback. Avoid inferring airflow, temperature limits or a fire response from a generic fan symbol; these require the room-services design.

## Information to show or reference

- Label the source and connection reference for cooling equipment health.
- Identify the destination and defined state of cooling available status.
- Record the equipment or control-document revision supporting this functional block.
- Check this application limit in the project design: Availability is different from thermal capacity.

## Important distinction

Availability is different from thermal capacity. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.

## Facts

- Representation: Functional block
- Installation focus: Switchrooms
- Input / boundary: Cooling equipment health
- Output / connection: Cooling available status
- Lookup label: SCI is a library lookup label, not a standard device designation.

## Public references

- [Ventilation in MV substations](https://www.electrical-installation.org/enwiki/Ventilation_in_MV_Substations) — Schneider Electric. Public technical context for switchroom ventilation interfaces. Heat removal, condensation and environmental design context. The application text and educational graphic are independently authored; the publisher does not certify this representation.