{"schemaVersion":1,"slug":"switchroom-environmental-sensor-fault-alarm","name":"Switchroom environmental sensor-fault alarm","kind":"symbol","abbreviation":"SESA","aliases":["Switchroom environmental supervision","switchrooms Switchroom environmental supervision","switchrooms","Switchrooms","Sensor quality status","Environmental input fault"],"category":"installation-communications","drawingTypes":["Schematic"],"referenceFamilies":["Manufacturer"],"summary":"Reports loss or invalidity of the assigned environmental measurement input.","description":["Reports loss or invalidity of the assigned environmental measurement input. Environmental supervision turns measurements or contact states into clearly named room-service indications. A sensor measures a condition; the supervisory function decides whether the assigned alarm or control response is needed.","In a switchroom, water ingress, temperature, humidity and equipment-service alarms can be sent to the station controller with separate point names so an operator can identify the affected area. For this reference, the drawing identifies “Sensor quality status” at the input and “Environmental input fault” at the output. Invalid data must not appear as a healthy room condition.","Keep sensor location, alarm thresholds, delay and monitoring coverage in the room-services schedule. An environmental alarm is a diagnostic input, not a complete assessment of electrical equipment condition. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation."],"readingNotes":["Start at the named input: Sensor quality status. Identify its source device or document and the state represented on the drawing.","Follow the named output: Environmental input fault. Cross-reference its destination and separate the command from confirmation that the equipment responded.","Invalid data must not appear as a healthy room condition.","Keep sensor location, alarm thresholds, delay and monitoring coverage in the room-services schedule. An environmental alarm is a diagnostic input, not a complete assessment of electrical equipment condition."],"drawingChecklist":["Label the source and connection reference for sensor quality status.","Identify the destination and defined state of environmental input fault.","Record the equipment or control-document revision supporting this functional block.","Check this application limit in the project design: Invalid data must not appear as a healthy room condition."],"distinction":"Invalid data must not appear as a healthy room condition. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.","facts":[{"label":"Representation","value":"Functional block"},{"label":"Installation focus","value":"Switchrooms"},{"label":"Input / boundary","value":"Sensor quality status"},{"label":"Output / connection","value":"Environmental input fault"},{"label":"Lookup label","value":"SESA is a library lookup label, not a standard device designation."}],"references":[{"sourceId":"pi26-ventilation","relevance":"Public technical context for switchroom environmental supervision. Heat removal, condensation and environmental design context. The application text and educational graphic are independently authored; the publisher does not certify this representation."}],"related":["relative-humidity-sensor","temperature-indicator","switchroom-temperature-high-high-alarm"],"artwork":"pi26-switchroom-environmental-sensor-fault-alarm","publishedOn":"2026-11-03","updatedOn":"2026-11-03","provenance":"independent-public-research","representation":{"type":"functional-block","focus":"switchrooms","family":"room-environment","input":"Sensor quality status","output":"Environmental input fault"},"plainEnglish":{"title":"What this block does","introduction":"Reports loss or invalidity of the assigned environmental measurement input.","example":"In a switchroom, water ingress, temperature, humidity and equipment-service alarms can be sent to the station controller with separate point names so an operator can identify the affected area. For this reference, the drawing identifies “Sensor quality status” at the input and “Environmental input fault” at the output. Invalid data must not appear as a healthy room condition.","drawings":"Start at the named input: Sensor quality status. Identify its source device or document and the state represented on the drawing. Follow the named output: Environmental input fault. Cross-reference its destination and separate the command from confirmation that the equipment responded.","terms":[{"name":"Input","meaning":"Sensor quality status"},{"name":"Output","meaning":"Environmental input fault"},{"name":"Application reference","meaning":"An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections."}],"diagram":"flow","steps":["Sensor quality status","SESA","Environmental input fault"],"caption":"A reading guide. The entry's original illustration and input/output facts describe this application.","sources":[{"label":"Ventilation in MV substations","url":"https://www.electrical-installation.org/enwiki/Ventilation_in_MV_Substations"}],"profileId":"power-installation-room-environment"},"url":"https://eloragrid.ai/symbols/switchroom-environmental-sensor-fault-alarm","illustration":{"url":"https://eloragrid.ai/tools/electrical-library/illustrations/switchroom-environmental-sensor-fault-alarm.svg","scope":"Original educational concept; not an official standard graphic or product footprint","license":"https://creativecommons.org/licenses/by/4.0/"},"sources":[{"id":"pi26-ventilation","publisher":"Schneider Electric","title":"Ventilation in MV substations","url":"https://www.electrical-installation.org/enwiki/Ventilation_in_MV_Substations","scope":"Heat removal, condensation and environmental design context.","type":"manufacturer","checkedOn":"2026-11-03","reuse":"link-only","relevance":"Public technical context for switchroom environmental supervision. Heat removal, condensation and environmental design context. The application text and educational graphic are independently authored; the publisher does not certify this representation."}]}