# Switchroom positive-DC earth alarm input

Canonical URL: https://eloragrid.ai/symbols/switchroom-positive-dc-earth-alarm-input
Publisher: Elora Grid
Updated: 2026-11-03
Lookup label: SPEAI
Drawing use: Schematic
Reference families: Manufacturer

Representation: Functional block
Installation focus: switchrooms
Input: DC insulation-monitor output
Output: Positive-side earth indication

Receives the insulation-monitor indication associated with the positive side of the assigned DC system.

## In plain English

### What this block does

Receives the insulation-monitor indication associated with the positive side of the assigned DC system.

### A simple example

In a switchroom, the station battery can continue supplying protection and breaker controls during an AC supply interruption. The alarm system should distinguish charger loss from a low battery condition. For this reference, the drawing identifies “DC insulation-monitor output” at the input and “Positive-side earth indication” at the output. Fault location requires the actual monitoring method.

### What the drawings help you do

Start at the named input: DC insulation-monitor output. Identify its source device or document and the state represented on the drawing. Follow the named output: Positive-side earth indication. Cross-reference its destination and separate the command from confirmation that the equipment responded.

### Terms

- Input: DC insulation-monitor output
- Output: Positive-side earth indication
- Application reference: An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections.

Concept diagram: DC insulation-monitor output → SPEAI → Positive-side earth indication
A reading guide. The entry's original illustration and input/output facts describe this application.

- [MicroGenius S2/S4 battery charger technical manual](https://www.sens-usa.com/hubfs/Controlled%20Files/Manuals/101330_MGS_User_Manual.pdf)


## What it represents

Receives the insulation-monitor indication associated with the positive side of the assigned DC system. A room DC interface connects station battery distribution, alarm contacts and operating circuits. DC supplies may remain energized when the room's normal AC supply is unavailable, so their source and distribution boundaries must be shown separately.
In a switchroom, the station battery can continue supplying protection and breaker controls during an AC supply interruption. The alarm system should distinguish charger loss from a low battery condition. For this reference, the drawing identifies “DC insulation-monitor output” at the input and “Positive-side earth indication” at the output. Fault location requires the actual monitoring method.
Identify the DC source, returns and monitored branches. Do not infer battery autonomy, conductor polarity, isolation or earthing arrangements from a generic power block. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation.

## How to read it

- Start at the named input: DC insulation-monitor output. Identify its source device or document and the state represented on the drawing.
- Follow the named output: Positive-side earth indication. Cross-reference its destination and separate the command from confirmation that the equipment responded.
- Fault location requires the actual monitoring method.
- Identify the DC source, returns and monitored branches. Do not infer battery autonomy, conductor polarity, isolation or earthing arrangements from a generic power block.

## Information to show or reference

- Label the source and connection reference for dc insulation-monitor output.
- Identify the destination and defined state of positive-side earth indication.
- Record the equipment or control-document revision supporting this functional block.
- Check this application limit in the project design: Fault location requires the actual monitoring method.

## Important distinction

Fault location requires the actual monitoring method. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.

## Facts

- Representation: Functional block
- Installation focus: Switchrooms
- Input / boundary: DC insulation-monitor output
- Output / connection: Positive-side earth indication
- Lookup label: SPEAI is a library lookup label, not a standard device designation.

## Public references

- [MicroGenius S2/S4 battery charger technical manual](https://www.sens-usa.com/hubfs/Controlled%20Files/Manuals/101330_MGS_User_Manual.pdf) — SENS. Public technical context for switchroom dc interfaces and alarm collection. Battery charging modes, DC distribution interfaces and charger alarms. The application text and educational graphic are independently authored; the publisher does not certify this representation.

## Graphic scope

Independent original educational concept illustration by Elora Grid. Not a certified standards graphic or manufacturer footprint. Unitless; not to scale. Original artwork licence: https://creativecommons.org/licenses/by/4.0/. Publisher material is linked only.
