{"schemaVersion":1,"slug":"transformer-overexcitation-measurement-interface","name":"Transformer overexcitation measurement interface","kind":"symbol","abbreviation":"TOMI","aliases":["Transformer protection and monitoring interfaces","substations Transformer protection and monitoring interfaces","substations","Substations","Voltage and frequency","Volts-per-hertz supervision input"],"category":"measurement-protection","drawingTypes":["Schematic"],"referenceFamilies":["Manufacturer"],"summary":"Relates the transformer voltage and frequency inputs to its selected overexcitation supervision.","description":["Relates the transformer voltage and frequency inputs to its selected overexcitation supervision. Transformer monitoring interfaces connect physical sensors and protection calculations to the station's alarms and trip logic. Temperature, oil, gas, pressure and electrical measurements indicate different conditions and require separate interpretation.","In a substation transformer bay, a protection panel receives winding-current measurements and equipment alarm contacts. An operator can then distinguish an electrical protection operation from a cooling-system or physical-condition alarm. For this reference, the drawing identifies “Voltage and frequency” at the input and “Volts-per-hertz supervision input” at the output. Allowed duty depends on transformer design.","Identify the sensor or calculation, its monitored zone and its assigned response. Alarm and trip thresholds, sensor fitting and protection settings belong to the selected transformer documentation and the approved protection design. The functional block is an independent explanation of this named application. Equipment-specific ratings, terminal connections and operating conditions must be established in the project documentation."],"readingNotes":["Start at the named input: Voltage and frequency. Identify its source device or document and the state represented on the drawing.","Follow the named output: Volts-per-hertz supervision input. Cross-reference its destination and separate the command from confirmation that the equipment responded.","Allowed duty depends on transformer design.","Identify the sensor or calculation, its monitored zone and its assigned response. Alarm and trip thresholds, sensor fitting and protection settings belong to the selected transformer documentation and the approved protection design."],"drawingChecklist":["Label the source and connection reference for voltage and frequency.","Identify the destination and defined state of volts-per-hertz supervision input.","Record the equipment or control-document revision supporting this functional block.","Check this application limit in the project design: Allowed duty depends on transformer design."],"distinction":"Allowed duty depends on transformer design. This reference describes the named application; it does not establish a new IEC graphical symbol, an ANSI device-function number or an exact manufacturer connection diagram.","facts":[{"label":"Representation","value":"Functional block"},{"label":"Installation focus","value":"Substations"},{"label":"Input / boundary","value":"Voltage and frequency"},{"label":"Output / connection","value":"Volts-per-hertz supervision input"},{"label":"Lookup label","value":"TOMI is a library lookup label, not a standard device designation."}],"references":[{"sourceId":"pi26-transformer-relay","relevance":"Public technical context for transformer protection and monitoring interfaces. Transformer protection, monitoring and measurement interfaces. The application text and educational graphic are independently authored; the publisher does not certify this representation."}],"related":["power-transformer","87t-transformer-differential-protection","transformer-bushing-monitor-alarm-interface"],"artwork":"pi26-transformer-overexcitation-measurement-interface","publishedOn":"2026-11-03","updatedOn":"2026-11-03","provenance":"independent-public-research","representation":{"type":"functional-block","focus":"substations","family":"transformer-monitoring","input":"Voltage and frequency","output":"Volts-per-hertz supervision input"},"plainEnglish":{"title":"What this block does","introduction":"Relates the transformer voltage and frequency inputs to its selected overexcitation supervision.","example":"In a substation transformer bay, a protection panel receives winding-current measurements and equipment alarm contacts. An operator can then distinguish an electrical protection operation from a cooling-system or physical-condition alarm. For this reference, the drawing identifies “Voltage and frequency” at the input and “Volts-per-hertz supervision input” at the output. Allowed duty depends on transformer design.","drawings":"Start at the named input: Voltage and frequency. Identify its source device or document and the state represented on the drawing. Follow the named output: Volts-per-hertz supervision input. Cross-reference its destination and separate the command from confirmation that the equipment responded.","terms":[{"name":"Input","meaning":"Voltage and frequency"},{"name":"Output","meaning":"Volts-per-hertz supervision input"},{"name":"Application reference","meaning":"An explanation of a named drawing function or circuit relationship; the project documents define the equipment and its connections."}],"diagram":"flow","steps":["Voltage and frequency","TOMI","Volts-per-hertz supervision input"],"caption":"A reading guide. The entry's original illustration and input/output facts describe this application.","sources":[{"label":"SEL-487E transformer protection relay","url":"https://selinc.com/products/487E/"}],"profileId":"power-installation-transformer-monitoring"},"url":"https://eloragrid.ai/symbols/transformer-overexcitation-measurement-interface","illustration":{"url":"https://eloragrid.ai/tools/electrical-library/illustrations/transformer-overexcitation-measurement-interface.svg","scope":"Original educational concept; not an official standard graphic or product footprint","license":"https://creativecommons.org/licenses/by/4.0/"},"sources":[{"id":"pi26-transformer-relay","publisher":"SEL","title":"SEL-487E transformer protection relay","url":"https://selinc.com/products/487E/","scope":"Transformer protection, monitoring and measurement interfaces.","type":"manufacturer","checkedOn":"2026-11-03","reuse":"link-only","relevance":"Public technical context for transformer protection and monitoring interfaces. Transformer protection, monitoring and measurement interfaces. The application text and educational graphic are independently authored; the publisher does not certify this representation."}]}